Phase artefact reduction in magnetic resonance electrical impedance tomography (MREIT)

被引:6
|
作者
Lee, Byung Il [1 ]
Park, Chunjae
Pyo, Hyun Chan
Kwon, Ohin
Woo, Eung Je
机构
[1] Kyung Hee Univ, Coll Elect & Informat, Seoul, South Korea
[2] Konkuk Univ, Dept Math, Seoul, South Korea
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 20期
关键词
D O I
10.1088/0031-9155/51/20/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cross-sectional conductivity imaging in magnetic resonance electrical impedance tomography (MREIT) requires the measurement of internal magnetic flux density using an MRI scanner. Current injection MRI techniques have been used to induce magnetic flux density distributions that appear in phase parts of the obtained MR signals. Since any phase error, as well as noise, deteriorates the quality of reconstructed conductivity images, we must minimize them during the data acquisition process. In this paper, we describe a new method to correct unavoidable phase errors to reduce artefacts in reconstructed conductivity images. From numerical simulations and phantom experiments, we found that the zeroth- and first-order phase errors can be effectively minimized to produce better conductivity images. The promising results suggest that this technique should be employed together with improved MREIT pulse sequences in future studies of high-resolution conductivity imaging.
引用
收藏
页码:5277 / 5288
页数:12
相关论文
共 50 条
  • [41] Equipotential line method for magnetic resonance electrical impedance tomography
    Kwon, O
    Lee, JY
    Yoon, JR
    INVERSE PROBLEMS, 2002, 18 (04) : 1089 - 1100
  • [42] Magnetic Resonance Driven Electrical Impedance Tomography: A Simulation Study
    Negishi, Michiro
    Tong, Tangji
    Constable, R. Todd
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (03) : 828 - 837
  • [43] Magnetic resonance electrical impedance tomography for measuring electrical conductivity during electroporation
    Kranjc, M.
    Bajd, F.
    Sersa, I.
    Miklavcic, D.
    PHYSIOLOGICAL MEASUREMENT, 2014, 35 (06) : 985 - 996
  • [44] Artefact reduction in fast Bayesian inversion in electrical tomography
    Zangl, Hubert
    Muehlbacher-Karrer, Stephan
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2015, 34 (05) : 1381 - 1391
  • [45] On the convergence of the harmonic BZ algorithm in magnetic resonance electrical impedance tomography
    Liu, J. J.
    Seo, J. K.
    Sini, M.
    Woo, E. J.
    SIAM JOURNAL ON APPLIED MATHEMATICS, 2007, 67 (05) : 1259 - 1282
  • [46] Magnetic resonance electrical impedance tomography at 3 Tesla field strength
    Oh, SH
    Lee, BI
    Park, TS
    Lee, SY
    Woo, EJ
    Cho, MH
    Seo, JK
    Kwon, O
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (06) : 1292 - 1296
  • [47] Magnetic resonance-electrical impedance tomography in breast cancer imaging
    Birgul, Ozlem
    Hamamura, Mark J.
    Muftuler, L. Turgan
    Nalcioglu, Orhan
    2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 686 - +
  • [48] The Nonlinear Variation Regularization Algorithm for the Magnetic Resonance Electrical Impedance Tomography
    Liu, Jin-Zhen
    Xiong, Hui
    Li, Gang
    Lin, Ling
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2015, 25 (01) : 68 - 76
  • [49] Fast Magnetic Resonance Electrical Impedance Tomography with Highly Undersampled Data
    Song, Yizhuang
    Ammari, Habib
    See, Jin Keun
    SIAM JOURNAL ON IMAGING SCIENCES, 2017, 10 (02): : 558 - 577
  • [50] Measurement of ion diffusion using magnetic resonance electrical impedance tomography
    Hamamura, Mark J.
    Muftuler, L. Tugan
    Birgul, Ozlem
    Nalcioglu, Orhan
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (11): : 2753 - 2762