Phase artefact reduction in magnetic resonance electrical impedance tomography (MREIT)

被引:6
|
作者
Lee, Byung Il [1 ]
Park, Chunjae
Pyo, Hyun Chan
Kwon, Ohin
Woo, Eung Je
机构
[1] Kyung Hee Univ, Coll Elect & Informat, Seoul, South Korea
[2] Konkuk Univ, Dept Math, Seoul, South Korea
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 20期
关键词
D O I
10.1088/0031-9155/51/20/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cross-sectional conductivity imaging in magnetic resonance electrical impedance tomography (MREIT) requires the measurement of internal magnetic flux density using an MRI scanner. Current injection MRI techniques have been used to induce magnetic flux density distributions that appear in phase parts of the obtained MR signals. Since any phase error, as well as noise, deteriorates the quality of reconstructed conductivity images, we must minimize them during the data acquisition process. In this paper, we describe a new method to correct unavoidable phase errors to reduce artefacts in reconstructed conductivity images. From numerical simulations and phantom experiments, we found that the zeroth- and first-order phase errors can be effectively minimized to produce better conductivity images. The promising results suggest that this technique should be employed together with improved MREIT pulse sequences in future studies of high-resolution conductivity imaging.
引用
收藏
页码:5277 / 5288
页数:12
相关论文
共 50 条
  • [21] Electrical conductivity imaging using gradient Bz decomposition algorithm in magnetic resonance electrical impedance tomography (MREIT)
    Park, C
    Kwon, O
    Woo, EJ
    Seo, JK
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (03) : 388 - 394
  • [22] Focused Current Density Imaging Using Internal Electrode in Magnetic Resonance Electrical Impedance Tomography (MREIT)
    Jeong, Woo Chul
    Sajib, Saurav Z. K.
    Kim, Hyung Joong
    Kwon, Oh In
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (07) : 1938 - 1946
  • [23] Magnetic resonance electrical impedance tomography (MREIT) based on the solution of the convection equation using FEM with stabilization
    Oran, Omer Faruk
    Ider, Yusuf Ziya
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (16):
  • [24] A new magnetic resonance electrical impedance tomography (MREIT) algorithm: the RSM-MREIT algorithm with applications to estimation of human head conductivity
    Gao, Nuo
    Zhu, S. A.
    He, Bin
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (12): : 3067 - 3083
  • [25] In vivo MRI electrical impedance tomography (MREIT) of tumors
    Muftuler, L. Tugan
    Hamamura, Mark J.
    Birgul, Ozlem
    Nalcioglu, Orhan
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2006, 5 (04) : 381 - 387
  • [26] Multi-frequency Electrical Impedance Tomography and Magnetic Resonance Electrical Impedance Tomography
    Seo, Jin Keun
    Woo, Eung Je
    MATHEMATICAL MODELING IN BIOMEDICAL IMAGING I: ELECTRICAL AND ULTRASOUND TOMOGRAPHIES, ANOMALY DETECTION, AND BRAIN IMAGING, 2009, 1983 : 1 - 71
  • [27] J-substitution algorithm in Magnetic Resonance Electrical Impedance Tomography (MREIT):: Phantom experiments for static resistivity images
    Khang, HS
    Lee, BI
    Oh, SH
    Woo, EJ
    Lee, SY
    Cho, MY
    Kwon, O
    Yoon, JR
    Seo, JK
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (06) : 695 - 702
  • [28] Conductivity Imaging of Animal and Human Body Using 3T Magnetic Resonance Electrical Impedance Tomography (MREIT)
    Jeong, W. C.
    Kim, Y. T.
    Kim, H. J.
    Lim, C. Y.
    Park, H. M.
    Woo, E. J.
    PROCEEDINGS OF PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS 2012), 2012, : 53 - 56
  • [29] Conductivity imaging of canine body using 3T magnetic resonance electrical impedance tomography (MREIT) system
    Kim, H. J.
    Kim, Y. T.
    Jeong, W. C.
    Minhas, A. S.
    Lim, C. Y.
    Park, H. M.
    Woo, E. J.
    SCIENTIA IRANICA, 2011, 18 (06) : 1505 - 1510
  • [30] Magnetic resonance electrical impedance tomography (MREIT):: Phantom experiments for static resistivity images using J-substitution algorithm
    Oh, SH
    Lee, BI
    Woo, EJ
    Lee, SY
    Cho, MH
    Kwon, O
    Yoon, JR
    Seo, JK
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 917 - 918