Phase artefact reduction in magnetic resonance electrical impedance tomography (MREIT)

被引:6
|
作者
Lee, Byung Il [1 ]
Park, Chunjae
Pyo, Hyun Chan
Kwon, Ohin
Woo, Eung Je
机构
[1] Kyung Hee Univ, Coll Elect & Informat, Seoul, South Korea
[2] Konkuk Univ, Dept Math, Seoul, South Korea
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 20期
关键词
D O I
10.1088/0031-9155/51/20/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cross-sectional conductivity imaging in magnetic resonance electrical impedance tomography (MREIT) requires the measurement of internal magnetic flux density using an MRI scanner. Current injection MRI techniques have been used to induce magnetic flux density distributions that appear in phase parts of the obtained MR signals. Since any phase error, as well as noise, deteriorates the quality of reconstructed conductivity images, we must minimize them during the data acquisition process. In this paper, we describe a new method to correct unavoidable phase errors to reduce artefacts in reconstructed conductivity images. From numerical simulations and phantom experiments, we found that the zeroth- and first-order phase errors can be effectively minimized to produce better conductivity images. The promising results suggest that this technique should be employed together with improved MREIT pulse sequences in future studies of high-resolution conductivity imaging.
引用
收藏
页码:5277 / 5288
页数:12
相关论文
共 50 条
  • [1] Magnetic Resonance Electrical Impedance Tomography (MREIT)
    Seo, Jin Keun
    Woo, Eung Je
    SIAM REVIEW, 2011, 53 (01) : 40 - 68
  • [2] Electrical conductivity imaging by magnetic resonance electrical impedance tomography (MREIT)
    Oh, SH
    Han, JY
    Lee, SY
    Cho, MH
    Lee, BI
    Woo, EJ
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (04) : 875 - 878
  • [3] COMPARISON OF MAGNETIC RESONANCE ELECTRICAL IMPEDANCE TOMOGRAPHY (MREIT) RECONSTRUCTION ALGORITHMS
    Eyuboglu, B. Murat
    Arpinar, V. Emre
    Boyacioglu, Rasim
    Degirmenci, Evren
    Eker, Gokhan
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 700 - 703
  • [4] Magnetic Resonance Electrical Impedance Tomography (MREIT): conductivity and current density imaging
    Seo, JK
    Kwon, O
    Woo, EJ
    SECOND INTERNATIONAL CONFERENCE ON INVERSE PROBLEMS: RECENT THEORETICAL DEVELOPMENTS AND NUMERICAL APPROACHES, 2004, 2005, 12 : 140 - 155
  • [5] Experimental Verification of Contrast Mechanism in Magnetic Resonance Electrical Impedance Tomography (MREIT)
    Kim, Young Tae
    Oh, Tong In
    Woo, Eung Je
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 4987 - 4990
  • [6] Sensitivity analysis of magnetic field measurements for magnetic resonance electrical impedance tomography (MREIT)
    Goksu, Cihan
    Scheffler, Klaus
    Ehses, Philipp
    Hanson, Lars G.
    Thielscher, Axel
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (02) : 748 - 760
  • [7] A Novel Conductivity Reconstruction Algorithm for Magnetic Resonance Electrical Impedance Tomography (MREIT)
    Wang, Yuyu
    Wang, Huixian
    Yang, Wenhui
    Hu, Xiaolin
    Song, Tao
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3976 - 3979
  • [8] Animal and Human Imaging Experiments in Magnetic Resonance Electrical Impedance Tomography (MREIT)
    Woo, Eung Je
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3165 - 3168
  • [9] Current injection optimization for magnetic resonance-electrical impedance tomography (MREIT)
    Altunel, H.
    Eyuboglu, B. M.
    Koksal, A.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 504 - +
  • [10] Magnetic Resonance Electrical Impedance Tomography (MREIT): Convergence and Reduced Basis Approach
    Garmatter, Dominik
    Harrach, Bastian
    SIAM JOURNAL ON IMAGING SCIENCES, 2018, 11 (01): : 863 - 887