Overvoltage Study on UHV AC Half Wave Length Transmission System

被引:0
|
作者
Gu, Peng [1 ]
Han, Bin [1 ]
Xiang, Zutao [1 ]
机构
[1] China Elect Power Res Inst, Beijing 100192, Peoples R China
关键词
Half wave length transmission; Ultra high voltage; Switching overvoltage; Grounding fault;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In China some resource bases in the west are located at a distance of about 2800 similar to 3000km from the load centers in the east. AC Half Wave Length transmission in UHV stage is an alternate for the long distance and large capacity power transmission. A study model of half wave length line transmission system was established. The power frequency overvoltage, switching overvoltage and grounding fault overvoltage were studied using EMTP. The study result shows that the highest overvoltage occurs during grounding faults. The amplitude and waveform of overvoltage during grounding fault are affected by fault type, fault location as well as the characteristic of the protection system. The use of metal oxide arresters to limit overvoltage is discussed. The parameters and configuration of metal oxide arresters is suggested.
引用
收藏
页码:237 / 245
页数:9
相关论文
共 50 条
  • [1] Overvoltage Mechanism, Properties and Restriction Requirements of AC Half-wave Length Transmission System
    Zhang Y.
    Han B.
    Qin X.
    Yixi C.
    Li S.
    Guo Y.
    Wang L.
    Dianwang Jishu/Power System Technology, 2023, 47 (06): : 2452 - 2462
  • [2] Reliability and Economic Analysis of UHV half-Wave-length AC Transmission
    Song Yunting
    Fan Bing
    Bai Yunxiao
    Qin Xiaohui
    Zhang Zhiqiang
    2012 IEEE INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2012,
  • [3] Research on diversities of power frequency overvoltage of UHV AC transmission system
    China Electric Power Research Institute, Haidian District, Beijing 100192, China
    不详
    不详
    Dianwang Jishu, 7 (1765-1771):
  • [4] Simulation Study of overvoltage in UHV AC and DC Hybrid System
    Li, Hongwei
    Peng, Ganrong
    2015 IEEE ADVANCED INFORMATION TECHNOLOGY, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (IAEAC), 2015, : 1215 - 1219
  • [5] A review of switching overvoltage modeling in UHV AC transmission lines
    Reddy, Sheri Abhishek
    Kumari, M. Sailaja
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 236
  • [6] Travelling Wave Protection of UHV Half-wavelength AC Transmission Lines
    Zheng Y.
    Si X.
    Wu T.
    Yao G.
    Hong F.
    Zheng X.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (18): : 124 - 131
  • [7] Mechanism and Mitigation of Power Fluctuation Overvoltage for Ultrahigh Voltage Half-Wave Length Transmission System
    Zhang, Yuanyuan
    Wang, Yi
    Han, Bin
    Ban, Liangeng
    Xiang, Zutao
    Song, Ruihua
    Qin, Xiaohui
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (03) : 1369 - 1377
  • [8] Study on lightning overvoltage and commutation failure in UHV AC/DC hybrid system
    Fang, Shengwei
    Zhang, Li
    Zou, Liang
    Chen, Yongshuai
    Wang, Yali
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 2677 - 2682
  • [9] Research on overvoltage and fault of a UHV AC/DC hybrid system
    Wang, Yali
    Zou, Liang
    Chen, Yongshuai
    Fang, Shengwei
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 2106 - 2111
  • [10] Study of Fault Direction Characteristic of Half-Wave-Length AC Transmission Lines
    Lei A.
    Dong X.
    Feng T.
    Tang L.
    Dianwang Jishu/Power System Technology, 2017, 41 (12): : 3832 - 3838