Misplaced Internal Juglar Vein Central Venous Catheter due to Thrombosis in Subclavian Vein: A Rare Occurrence

被引:0
作者
Sethi, Sameer [1 ]
Dhiman, Deepanshu [1 ]
Lileswar, Kaman [2 ]
Singh, Kaptan [2 ]
机构
[1] Postgrad Inst Hlth Sci, Dept Anaesthesia & Intens Care, Chandigarh, India
[2] Postgrad Inst Hlth Sci, Dept Gen Surg, Chandigarh, India
关键词
Complications of central venous catheters; Misdirected catheters; Ultrasound; Venous thrombosis;
D O I
10.7860/JCDR/2019/41831.13118
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Here, authors report a case of Central Venous Catheter (CVC) malposition in a patient posted for Whipple's procedure. A 65-yearold male diagnosed with carcinoma head of pancreas, post-chemotherapy was posted for Whipple's procedure. Ultrasound (USG) guidance CVC line and arterial cannula placement were planned for invasive monitoring and administration of fluids and drugs postoperatively. A post-operative chest radiograph was done which showed that the CVC was malpositioned into the subclavian vein. The venography delineated a clot at the junction of the Internal Jugular Vein (IJV) and the Subclavian Vein (SCV). It was further concluded that presence of this thrombus at the junction of both the vessels prevented the movement of the guidewire towards the Superior Vena Cava (SVC) and therefore the catheter into the SVC. This case report highlights the use of USG not only to visualise the target vessel but also to scan completely till the junction SVC and right atrium for any clot or anatomic malformations in the vasculature.
引用
收藏
页码:UD1 / UD2
页数:2
相关论文
共 7 条
[1]   Central vein stenosis: A nephrologist's perspective [J].
Agarwal, Anil K. ;
Patel, Bhairavi M. ;
Haddad, Nabil J. .
SEMINARS IN DIALYSIS, 2007, 20 (01) :53-62
[2]   Pictorial review - Venous anomalies of the thorax [J].
Demos, TC ;
Posniak, HV ;
Pierce, KL ;
Olson, MC ;
Muscato, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (05) :1139-1150
[3]  
Palepu Gopal B, 2009, Indian J Radiol Imaging, V19, P191, DOI 10.4103/0971-3026.54877
[4]   Influence of orientations of guidewire tip on the placement of subclavian venous catheters [J].
Park, HP ;
Jeon, Y ;
Hwang, J ;
Han, SH ;
Bahk, JH ;
Oh, YS .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2005, 49 (10) :1460-1463
[5]   Central Venous Catheter Intravascular Malpositioning: Causes, Prevention, Diagnosis, and Correction [J].
Roldan, Carlos J. ;
Paniagua, Linda .
WESTERN JOURNAL OF EMERGENCY MEDICINE, 2015, 16 (05) :658-664
[6]   Mechanical complications and malpositions of central venous cannulations by experienced operators - A prospective study of 1794 catheterizations in critically ill patients [J].
Schummer, Wolfram ;
Schummer, Claudia ;
Rose, Norman ;
Niesen, Wolf-Dirk ;
Sakka, Samir G. .
INTENSIVE CARE MEDICINE, 2007, 33 (06) :1055-1059
[7]   Vascular erosion by central venous catheters used for total parenteral nutrition [J].
Walshe, Criona ;
Phelan, Dermot ;
Bourke, Jane ;
Buggy, Donal .
INTENSIVE CARE MEDICINE, 2007, 33 (03) :534-537