Featuring ultimate sensitivity of high-resolution LC-MS analysis of phenolics in rat plasma

被引:4
作者
Vlckova, Hana Kocova [1 ]
Catapano, Maria Carmen [1 ]
Mitasik, Lucia [1 ]
Kotland, Ondrej [2 ]
Nejmanova, Iveta [3 ]
Pourova, Jana [3 ]
Mladenka, Ptemysl [3 ]
Novakova, Lucie [1 ]
机构
[1] Charles Univ Prague, Fac Pharm Hradec Kralove, Dept Analyt Chem, Heyrovskeho 1203, Hradec Kralove, Czech Republic
[2] Waters Gesell MbH, Prague 4, Czech Republic
[3] Charles Univ Prague, Fac Pharm Hradec Kralove, Dept Pharmacol & Toxicol, Hradec Kralove, Czech Republic
关键词
high‐ resolution mass spectrometry; low‐ molecular weight analytes; metabolites; phenolics; quadrupole‐ time‐ of‐ flight; PERFORMANCE LIQUID-CHROMATOGRAPHY; FLIGHT MASS-SPECTROMETRY;
D O I
10.1002/jssc.202100054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sensitive analysis of very low-molecular weight metabolites using liquid chromatography with quadrupole-time-of-flight mass spectrometry is challenging due to the high losses of ions in a time-of-flight analyzer. Improvement in sensitivity for these analytes via the optimization of advanced parameters, including quadrupole profile, ion guide parameters, and duty cycle, has been achieved. The optimization of the method was carried out using a large spectrum of structurally different compounds including (iso)flavonoids and their known metabolites. These compounds can be categorized into two major groups, that is, compounds with (iso)flavonoid core and low-molecular weight phenolics. The optimization of the duty cycle enabled up to a 15-fold increase in analyte responses while the contribution of tuning ion optics and quadrupole profile was negligible. The limits of quantifications of our new method were assessed using both standard solutions and rat plasma. They were decreased at least 10 times for several low-molecular weight phenolics enabling measurement of their concentrations in a range of 1-50 ng/mL in rat plasma after protein precipitation. Concurrently, the limits of quantifications for compounds with (iso)flavonoid core did not increase distinctly allowing their detection in a range of 0.5-10 ng/mL. The new method was used for the targeting of phenolics in biological samples from pharmacokinetics experiments.
引用
收藏
页码:1904 / 1912
页数:9
相关论文
共 27 条
[1]   HPLC-ESI-Q-TOF-MS for a comprehensive characterization of bioactive phenolic compounds in cucumber whole fruit extract [J].
Abu-Reidah, Ibrahim M. ;
Arraez-Roman, David ;
Quirantes-Pine, Rosa ;
Fernandez-Arroyo, Salvador ;
Segura-Carretero, Antonio ;
Fernandez-Gutierrez, Alberto .
FOOD RESEARCH INTERNATIONAL, 2012, 46 (01) :108-117
[2]   The Impact II, a Very High-Resolution Quadrupole Time-of-Flight Instrument (QTOF) for Deep Shotgun Proteomics [J].
Beck, Scarlet ;
Michalski, Annette ;
Raether, Oliver ;
Lubeck, Markus ;
Kaspar, Stephanie ;
Goedecke, Niels ;
Baessmann, Carsten ;
Hornburg, Daniel ;
Meier, Florian ;
Paron, Igor ;
Kulak, Nils A. ;
Cox, Juergen ;
Mann, Matthias .
MOLECULAR & CELLULAR PROTEOMICS, 2015, 14 (07) :2014-2029
[3]   Duty cycle improvement for a quadrupole-time-of-flight mass spectrometer and its use for precursor ion scans [J].
Chernushevich, IV .
EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2000, 6 (06) :471-479
[4]   An introduction to quadrupole-time-of-flight mass spectrometry [J].
Chernushevich, IV ;
Loboda, AV ;
Thomson, BA .
JOURNAL OF MASS SPECTROMETRY, 2001, 36 (08) :849-865
[5]   Comparison of Different Time of Flight-Mass Spectrometry Modes for Small Molecule Quantitative Analysis [J].
Chindarkar, Nandkishor S. ;
Park, Hyung-Doo ;
Stone, Judith A. ;
Fitzgerald, Robert L. .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2015, 39 (09) :675-685
[6]   A fully automated method for accurate mass determination using high-performance liquid chromatography with a quadrupole/orthogonal acceleration time-of-flight mass spectrometer [J].
Colombo, M ;
Sirtori, FR ;
Rizzo, V .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (04) :511-517
[7]   Development and validation of a high-throughput micro solid-phase extraction method coupled with ultra-high-performance liquid chromatography-quadrupole time-of-flight mass spectrometry for rapid identification and quantification of phenolic metabolites in human plasma and urine [J].
Feliciano, Rodrigo P. ;
Mecha, Elsa ;
Bronze, Maria R. ;
Rodriguez-Mateos, Ana .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1464 :21-31
[8]   Applications of a travelling wave-based radio-frequencyonly stacked ring ion guide [J].
Giles, K ;
Pringle, SD ;
Worthington, KR ;
Little, D ;
Wildgoose, JL ;
Bateman, RH .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (20) :2401-2414
[9]  
Gordon, NEW CONJOINED RF ION
[10]   Tuning a High Transmission Ion Guide to Prevent Gas-Phase Proton Exchange During H/D Exchange MS Analysis [J].
Guttman, Miklos ;
Wales, Thomas E. ;
Whittington, Dale ;
Engen, John R. ;
Brown, Jeffery M. ;
Lee, Kelly K. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2016, 27 (04) :662-668