Evaluation of CMOS APS imager for digital radiography and mammography

被引:0
|
作者
Kim, KH [1 ]
Chae, JS [1 ]
Yuk, SW [1 ]
Kim, YS [1 ]
Chi, YK [1 ]
Cho, G [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Nucl Quantum Engn, Taejon 305701, South Korea
来源
2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5 | 2004年
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We evaluated image performance of scintillator coupled CMOS APS imager for radiography and mammography conditions, respectively. 80 kVp and 28 kVp of X-ray tube voltage at the SID of 720 mm and 600 turn were set for each condition. Commercially available scintillator such as Lanex screen, needle structured CsI (TI), and fiber optic structured CsI (TI) were coupled CMOS APS imager. From the experimental results, needle CsI type scintillator was candidate in radiography condition, having 45 % at 3 mm(-1). However, at the higher frequency no scintillator showed good DQE in mammography condition although Lanex Fine scintillator has DQE of 0.5 at 6 mm(-1).
引用
收藏
页码:3190 / 3194
页数:5
相关论文
共 50 条
  • [1] Scintillator and CMOS APS imager for radiography conditions
    Kim, Kwang Hyun
    Kim, Young Soo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) : 1327 - 1332
  • [2] PROTON RADIOGRAPHY WITH CMOS APS
    Reyes, E. Gelover
    Spang, F. Jimenez
    Rosenberg, I.
    Royle, G.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S531 - S531
  • [3] Normal Optical Flow Measurement on a CMOS APS imager
    Mehta, S
    Etienne-Cummings, R
    2004 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL 4, PROCEEDINGS, 2004, : 848 - 851
  • [4] Normal optical flow measurement on CMOS APS imager
    Mehta, S
    Etienne-Cummings, R
    ELECTRONICS LETTERS, 2005, 41 (13) : 732 - 733
  • [5] CMOS Active Pixel Sensor (APS) imager for scientific applications
    Ay, SU
    Lesser, M
    Fossum, ER
    SURVEY AND OTHER TELESCOPE TECHNOLOGIES AND DISCOVERIES, 2002, 4836 : 271 - 278
  • [6] Radiation characteristics of scintillator coupled CMOS APS for radiography conditions
    Kim, Kwang Hyun
    Kim, Soongpyung
    Kang, Dong-Won
    Kim, Dong-Kie
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (01): : 124 - 127
  • [7] Physical and psychophysical evaluation of a new digital specimen radiography system for use in mammography
    Krupinski, EA
    Roehrig, H
    Schempp, W
    MEDICAL IMAGING 2000: IMAGE PERCEPTION AND PERFORMANCE, 2000, 3981 : 208 - 215
  • [8] Evaluation of a Novel Wafer-Scale CMOS APS X-Ray Detector for Use in Mammography
    Konstantinidis, Anastasios C.
    Zheng, Yi
    Olivo, Alessandro
    Bliznakova, Kristina
    Yip, Mary
    Anaxagoras, Thalis
    Wells, Kevin
    Allinson, Nigel
    Speller, Robert D.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3254 - 3260
  • [9] Comparison of conventional and digital radiography in lizards. Mammography technique versus digital radiography
    Bochmann, M.
    Ludewig, E.
    Pees, M.
    TIERAERZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2011, 39 (04): : 259 - 267
  • [10] Evaluation of a full-field clinical prototype flat panel imager for digital mammography
    Karellas, A
    Vedantham, S
    Levis, I
    Albagli, D
    Han, S
    Landberg, CE
    RADIOLOGY, 1998, 209P : 159 - 159