Effect of Pressure Support Ventilation on Carboxyhemoglobin Toxicokinetic after Acute Carbon Monoxide Intoxication: a Swine Model

被引:4
作者
Delvau, N. [1 ]
Penaloza, A. [1 ]
Liistro, G. [2 ]
Thys, F. [3 ]
Delattre, I. K. [4 ]
Hantson, Philippe [4 ,5 ]
Gianello, P. [6 ]
Roy, P. M. [7 ]
机构
[1] Catholic Univ Louvain, Clin Univ St Luc, Dept Emergency Med, B-1200 Brussels, Belgium
[2] Catholic Univ Louvain, Clin Univ St Luc, Dept Pneumol, B-1200 Brussels, Belgium
[3] Grand Hop Charleroi, Emergency Dept, B-6000 Charleroi, Belgium
[4] Catholic Univ Louvain, Louvain Ctr Toxicol & Appl Pharmacol LTAP, B-1200 Brussels, Belgium
[5] Catholic Univ Louvain, Clin Univ St Luc, Dept Intens Care, Ave Hippocrate 10, B-1200 Brussels, Belgium
[6] Catholic Univ Louvain, Dept Hlth Sci, Inst Expt & Clin Expt Surg & Transplantat CHEX, B-1200 Brussels, Belgium
[7] Ctr Hosp Univ, Dept Emergency Med, F-49033 Angers 01, France
关键词
Carbon monoxide; Swine; Positive pressure ventilation; Continuous positive airway pressure (CPAP); Toxicokinetic; Carboxyhemoglobin (COHb); Oxygen therapy; FACE MASK; OXYGEN; EXPOSURE;
D O I
10.1007/s13181-018-0654-8
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
In an experimental study on carbon monoxide (CO) exposure in swine, we aimed to compare the influence of oxygen therapy using a non-rebreathing mask (NRM) to continuous positive airway pressure (CPAP) and two pressure support ventilation (PSV) devices on the decrease of the terminal elimination half-life of carboxyhemoglobin (COHb t(1/2)). This was the primary outcome. Eight spontaneously breathing pigs were sedated by propofol and exposed to 940 ppm CO several times (n = 25) to obtain COHb levels of 30%. CPAPb (high flow open system, CPAP BoussignacA (R) [7.5 cmH(2)O]), PSV-Vy (open system, Vylife BoussignacA (R)), and PSV-Leg (closed system, LegendairA (R) [inspiratory/expiratory airway pressure 12/4 cmH(2)O]) devices were used in a randomized order and compared to NRM (O-2 at 15 l min(-1)) and atmospheric air (AA). The primary outcome was COHb t(1/2). Multiple comparisons were performed using Dunn's tests. Median FiO(2) and minute ventilation were significantly higher in the PSV-Leg group than the NRM group (p < 0.05). Median COHb t(1/2) was 251, 85, 82, 93, and 58 min for AA, NRM, CPAPb, PSV-Vy, and PSV-Leg, respectively. All the interventions were superior to AA in terms of CO elimination (p < 0.001), but there was no statistically significant difference between CPAP or PSV and NRM. There was only a trend between PSV-Leg and NRM (p = 0.18). The median AUCs for ln (COHb) x time (h) were 170, 79, 83, 100, and 64 for AA, NRM, CPAPb, PSV-Vy, and PSV-Leg respectively, with a statistically significant difference only between AA and PSV-Leg (p = 0.002). In conclusion, in our study on CO intoxication in swine, the use of the closed PSV-Leg system led to the shortest COHb t(1/2). These results suggest that PSV-Leg can be more efficient than NRM in eliminating CO and support the design of a clinical study to assess this hypothesis.
引用
收藏
页码:128 / 133
页数:6
相关论文
共 17 条
[11]   ACCELERATION OF CARBON MONOXIDE ELIMINATION IN MAN BY HIGH PRESSURE OXYGEN [J].
PACE, N ;
STRAJMAN, E ;
WALKER, EL .
SCIENCE, 1950, 111 (2894) :652-654
[12]   OXYGEN AND CARBON MONOXIDE EQUILIBRIA OF HUMAN ADULT HEMOGLOBIN AT ATMOSPHERIC AND ELEVATED PRESSURE [J].
RODKEY, FL ;
ONEAL, JD ;
COLLISON, HA .
BLOOD-THE JOURNAL OF HEMATOLOGY, 1969, 33 (01) :57-&
[13]   Miniature Swine for Preclinical Modeling of Complexities of Human Disease for Translational Scientific Discovery and Accelerated Development of Therapies and Medical Devices [J].
Schomberg, Dominic T. ;
Tellez, Armando ;
Meudt, Jennifer J. ;
Brady, Dane A. ;
Dillon, Krista N. ;
Arowolo, Folagbayi K. ;
Wicks, Joan ;
Rousselle, Serge D. ;
Shanmuganayagam, Dhanansayan .
TOXICOLOGIC PATHOLOGY, 2016, 44 (03) :299-314
[14]   Practical use, effects and complications of prehospital treatment of acute cardiogenic pulmonary edema using the Boussignac CPAP system [J].
Spijker E.E. ;
De Bont M. ;
Bax M. ;
Sandel M. .
International Journal of Emergency Medicine, 6 (1)
[15]   Laboratory testing measurement of FIO2 delivered by Boussignac CPAP system with an input of 100% oxygen [J].
Templier, F ;
Dolveck, F ;
Baer, M ;
Chauvin, A ;
Fletcher, D .
ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2003, 22 (02) :103-107
[16]  
Thys F, 1999, Eur J Emerg Med, V6, P207
[17]   MEASUREMENT OF INTRATRACHEAL OXYGEN CONCENTRATIONS DURING FACE MASK ADMINISTRATION OF OXYGEN - MODIFICATION FOR IMPROVED CONTROL [J].
WEXLER, HR ;
ABERMAN, A ;
SCOTT, AA ;
COOPER, JD .
CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1975, 22 (04) :417-431