Integrated Direct/Indirect Adaptive Robust Posture Trajectory Tracking Control of a Parallel Manipulator Driven by Pneumatic Muscles

被引:59
作者
Zhu, Xiaocong [1 ]
Tao, Guoliang [1 ]
Yao, Bin [1 ]
Cao, Jian [1 ]
机构
[1] Zhejiang Univ, State Key Lab Fluid Power Transmiss & Control, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金;
关键词
Adaptive control; nonlinear systems; parallel manipulator; parameter estimation; pneumatic muscle; SISO NONLINEAR-SYSTEMS; MOTION CONTROL; ROBOT;
D O I
10.1109/TCST.2008.2001715
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
An integrated direct/indirect adaptive robust controller (DIARC) is proposed to further improve the achievable posture trajectory tracking control performance of a parallel manipulator driven by pneumatic muscles. Due to the model errors of the static forces and friction forces of pneumatic muscles, the simplified average flow rate characteristics of valves, and the unknown disturbances of entire system, there exist large extent of parametric uncertainties and rather severe uncertain nonlinearities in the modeling of the parallel manipulator. To address these problems, in this paper, an indirect type parameter estimation is used to obtain reliable estimates of effective model parameters for reducing the parametric uncertainties while an integrated direct/indirect ARC with dynamic compensation type fast adaptation is utilized to further attenuate the influences of uncertain nonlinearities for better tracking performance. Considering that the conventional parameter estimation algorithm based on single error minimizing criterion normally fails to provide reliable parameter estimation for the parallel manipulator with symmetric structure due to the difficulty in satisfying the persistent exciting conditions all the time-the theoretical requirement for the convergence of online parameter estimation, additional practical constraints are imposed to further condition the parameter estimation process and a new parameter estimation algorithm based on composite error minimizing criterion in task-space is developed. Experimental results demonstrate that the parallel manipulator under the control of the proposed integrated DIARC has strong self-adaptability and robustness with the steady-state posture tracking error being less than 0.01 degrees, average tracking error less than 0.1 degrees, and maximum tracking error less than 0.3 degrees, which are significantly better than those of the direct ARC.
引用
收藏
页码:576 / 588
页数:13
相关论文
共 29 条
[1]  
[Anonymous], 2004, APPL NONLINEAR CONTR
[2]  
Astrom K.J., 1995, ADAPTIVE CONTROL
[3]   Nonlinear control of a pneumatic muscle actuator: Backstepping vs. sliding-mode [J].
Carbonell, P ;
Jiang, ZP ;
Repperger, DW .
PROCEEDINGS OF THE 2001 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS (CCA'01), 2001, :167-172
[4]   Measurement and modeling of McKibben pneumatic artificial muscles [J].
Chou, CP ;
Hannaford, B .
IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 1996, 12 (01) :90-102
[5]  
Hesse S., 2003, The Fluidic Muscle in Application, 150 Practical Examples Using the Pneumatic Muscle
[6]   Cascaded control concept of a robot with two degrees of freedom driven by four artificial pneumatic muscle actuators [J].
Hildebrandt, A ;
Sawodny, O ;
Neumann, R ;
Hartmann, A .
ACC: PROCEEDINGS OF THE 2005 AMERICAN CONTROL CONFERENCE, VOLS 1-7, 2005, :680-685
[7]  
HILDEBRANDT A, 2002, P 7 INT C CONTR AUT, P1156
[8]  
Kawashima K, 2003, IROS 2003: PROCEEDINGS OF THE 2003 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-4, P3384
[9]  
Kerscher T., 2006, Proceedings of the BioRob 2006, Pisa, P637
[10]  
Khalil H. K., 2002, Nonlinear systems, V3