Intensity-modulated radiation therapy (IMRT) dosimetry of the head and neck: A comparison of treatment plans using linear accelerator-based IMRT and helical tomotherapy

被引:110
作者
Sheng, Ke
Molloy, Janelle A.
Read, Paul W.
机构
[1] Univ Virginia, Dept Radiat Oncol, Charlottesville, VA 22908 USA
[2] Mayo Clin, Dept Radiat Oncol, Rochester, MN USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2006年 / 65卷 / 03期
关键词
intensity-modulated radiation therapy; tomotherapy; oropharyngeal carcinoma; treatment planning; LEAF-WIDTH; POSTOPERATIVE IMRT; CANCER; RADIOTHERAPY; DELINEATION; PATTERNS; IRRADIATION; XEROSTOMIA; CARCINOMA; FAILURE;
D O I
10.1016/j.ijrobp.2006.02.038
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To date, most intensity-modulated radiation therapy (IMRT) delivery has occurred using linear accelerators (linacs), although helical tomotherapy has become commercially available. To quantify the dosimetric difference, we compared linac-based and helical tomotherapy-based treatment plans for IMRT of the oropharynx. Methods and Materials: We compared the dosimetry findings of 10 patients who had oropharyngeal carcinoma. Five patients each had cancers in the base of the tongue and tonsil. Each plan was independently optimized using either the CORVUS planning system (Nomos Corporation, Sewickly, PA), commissioned for a Varian 2300 CD linear accelerator (Varian Medical Systems, Palo Alto, CA) with 1-cm multileaf collimator leaves, or helical tomotherapy. The resulting treatment plans were evaluated by comparing the dose-volume histograms, equivalent uniform dose (EUD), dose uniformity, and normal tissue complication probabilities. Results: Helical tomotherapy plans showed improvement of critical structure avoidance and target dose uniformity for all patients. The average equivalent uniform dose reduction for organs at risk (OARs) surrounding the base of tongue and the tonsil were 17.4% and 27.14% respectively. An 80% reduction in normal tissue complication probabilities for the parotid glands was observed in the tomotherapy plans relative to the linac-based plans. The standard deviation of the planning target volume dose was reduced by 71%. In our clinic, we use the combined dose-volume histograms for each class of plans as a reference goal for helical tomotherapy treatment planning optimization. Conclusions: Helical tomotherapy provides improved dose homogeneity and normal structure dose compared with linac-based IMRT in the treatment of oropharyngeal carcinoma resulting in a reduced risk for complications from focal hotspots within the planning target volume and for the adjacent parotid glands. (c) 2006 Elsevier Inc.
引用
收藏
页码:917 / 923
页数:7
相关论文
共 27 条
[1]   The role of intensity-modulated radiotherapy in the treatment of parotid tumors [J].
Bragg, CM ;
Conway, J ;
Robinson, MH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (03) :729-738
[2]   FITTING OF NORMAL TISSUE TOLERANCE DATA TO AN ANALYTIC-FUNCTION [J].
BURMAN, C ;
KUTCHER, GJ ;
EMAMI, B ;
GOITEIN, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :123-135
[3]   Effect of MLC leaf width on the planning and delivery of SMLC IMRT using the CORVUS inverse treatment planning system [J].
Burmeister, J ;
McDermott, PN ;
Bossenberger, T ;
Ben-Josef, E ;
Levin, K ;
Forman, JD .
MEDICAL PHYSICS, 2004, 31 (12) :3187-3193
[4]   Smart (simultaneous modulated accelerated radiation therapy) boost: A new accelerated fractionation schedule for the treatment of head and neck cancer with intensity modulated radiotherapy [J].
Butler, EB ;
Teh, BS ;
Grant, WH ;
Uhl, BM ;
Kuppersmith, RB ;
Chiu, JK ;
Donovan, DT ;
Woo, SY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (01) :21-32
[5]   Intensity-modulated radiation therapy reduces late salivary toxicity without compromising tumor control in patients with oropharyngeal carcinoma: a comparisons with conventional techniques [J].
Chao, KSC ;
Majhail, N ;
Huang, CJ ;
Simpson, JR ;
Perez, CA ;
Haughey, B ;
Spector, G .
RADIOTHERAPY AND ONCOLOGY, 2001, 61 (03) :275-280
[6]   Patterns of failure in patients receiving definitive and postoperative IMRT for head-and-neck cancer [J].
Chao, KSC ;
Ozyigit, G ;
Tran, BN ;
Cengiz, M ;
Dempsey, JF ;
Low, DA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (02) :312-321
[7]   Determination and delineation of nodal target volumes for head-and-neck cancer based on patterns of failure in patients receiving definitive and postoperative IMRT [J].
Chao, KSC ;
Wippold, FJ ;
Ozyigit, G ;
Tran, BN ;
Dempsey, JF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1174-1184
[8]   A prospective study of salivary function sparing in patients with head-and-neck cancers receiving intensity-modulated or three-dimensional radiation therapy: Initial results [J].
Chao, KSC ;
Deasy, JO ;
Markman, J ;
Haynie, J ;
Perez, CA ;
Purdy, JA ;
Low, DA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (04) :907-916
[9]   Dosimetric effect of collimating jaws for small multileaf collimated fields [J].
Chow, JCL ;
Seguin, M ;
Alexander, A .
MEDICAL PHYSICS, 2005, 32 (03) :759-765
[10]   An implementation strategy for IMRT of ethmoid sinus cancer with bilateral sparing of the optic pathways [J].
Claus, F ;
De Gersem, W ;
De Wagter, C ;
Van Severen, R ;
Vanhoutte, I ;
Duthoy, W ;
Remouchamps, V ;
Van Duyse, B ;
Vakaet, L ;
Lemmerling, M ;
Vermeersch, H ;
De Neve, W .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (02) :318-331