Subarray coherence based postfilter for eigenspace based minimum variance beamformer in ultrasound plane-wave imaging

被引:56
作者
Zhao, Jinxin [1 ,3 ]
Wang, Yuanyuan [1 ,2 ]
Yu, Jinhua [1 ,2 ]
Guo, Wei
Li, Tianjie [3 ]
Zheng, Yong-Ping [3 ]
机构
[1] Fudan Univ, Dept Elect Engn, Shanghai 200433, Peoples R China
[2] Key Lab Med Imaging Comp & Comp Assisted Interven, Shanghai 200433, Peoples R China
[3] Hong Kong Polytech Univ, Interdisciplinary Div Biomed Engn, Hong Kong, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Eigenspace based minimum variance beamformer; Coherence; Plane-wave imaging; Subarray; Wiener postfilter; TRANSIENT ELASTOGRAPHY; ULTRASONOGRAPHY; GPU;
D O I
10.1016/j.ultras.2015.10.026
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper introduces a new beamformer, which combines the eigenspace based minimum variance (ESBMV) beamformer with a subarray coherence based postfilter (SCBP), for improving the quality of ultrasound plane-wave imaging. The ESBMV beamformer has been validated in improving the imaging contrast, but the difficulty in dividing the signal subspace limits the usage of it in the low signal-to-noise ratio (SNR) scenarios. Coherence factor (CF) based methods could optimize the output of a distortionless beamformer to reduce sidelobes, but the influence by the subarray decorrelation technique on the postfilter design has not attracted enough concern before. Accordingly, an ESBMV-SCBP beamformer was proposed in this paper, which used the coherence of the subarray signal to compute an SCBP to optimize the ESBMV results. Simulated and experimental data were used to evaluate the performance of the proposed method. The results showed that the ESBMV-SCBP method achieved an improved imaging quality compared with the ESBMV beamformer. In the simulation study, the contrast ratio (CR) for an anechoic cyst was improved by 9.88 dB and the contrast-to-noise ratio (CNR) was improved by 0.97 over the ESBMV. In the experimental study, the CR improvements for two anechoic cysts were 7.32 dB and 9.45 dB, while the CNRs were improved by 1.27 and 0.66, respectively. The ESBMV-SCBP also showed advantages over the ESBMV-Wiener beamformer in preserving a less grainy speckle, which is closer to that of distortionless beamformers and benefits the imaging contrast. With a relatively small extra computational load, the proposed method has potential to enhance the quality of the ultrasound plane-wave imaging. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:23 / 33
页数:11
相关论文
共 30 条
[21]   Optimum Beamforming for Sidelobe Reduction in Ultrasound Imaging [J].
Sakhaei, Sayed Mahmoud .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (04) :799-805
[22]   Shear modulus imaging with 2-D transient elastography [J].
Sandrin, L ;
Tanter, M ;
Catheline, S ;
Fink, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (04) :426-435
[23]   Adaptive beamforming applied to medical ultrasound imaging [J].
Synnevag, Johan-Fredrik ;
Austeng, Andreas ;
Holm, Sverre .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (08) :1606-1613
[24]   Benefits of Minimum-Variance Beamforming in Medical Ultrasound Imaging [J].
Synnevag, Johan-Fredrik ;
Austeng, Andreas ;
Holm, Sverre .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (09) :1868-1879
[25]  
Tanter M, 2014, IEEE T ULTRASON FERR, V61, P102, DOI [10.1109/TUFFC.2014.6689779, 10.1109/TUFFC.2014.2882]
[26]   MVDR-Based Coherence Weighting for High-Frame-Rate Adaptive Imaging [J].
Wang, Shun-Li ;
Li, Pai-Chi .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (10) :2097-2110
[27]   SNR-Dependent Coherence-Based Adaptive Imaging for High-Frame-Rate Ultrasonic and Photoacoustic Imaging [J].
Wang, Yu-Hsin ;
Li, Pai-Chi .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (08) :1419-1432
[28]  
Xu ML, 2014, IEEE T ULTRASON FERR, V61, P182, DOI [10.1109/TUFFC.2014.6689786, 10.1109/TUFFC.2014.2889]
[29]   GPU-BASED MINIMUM VARIANCE BEAMFORMER FOR SYNTHETIC APERTURE IMAGING OF THE EYE [J].
Yiu, Billy Y. S. ;
Yu, Alfred C. H. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (03) :871-883
[30]   Eigenspace-based minimum variance beamformer combined with Wiener postfilter for medical ultrasound imaging [J].
Zeng, Xing ;
Chen, Cheng ;
Wang, Yuanyuan .
ULTRASONICS, 2012, 52 (08) :996-1004