Comparison of tolerance to induced astigmatism in pseudophakic eyes implanted with small aperture, trifocal, or monofocal intraocular lenses

被引:16
|
作者
Edward Ang, Robert [1 ]
机构
[1] Asian Eye Inst, Dept Cornea & Refract Surg, Makati, Philippines
来源
CLINICAL OPHTHALMOLOGY | 2019年 / 13卷
关键词
cataract; refractive error; small aperture IOL; residual astigmatism; RESIDUAL REFRACTIVE ERROR; CORNEAL ASTIGMATISM; CATARACT-SURGERY; VISUAL-ACUITY; PREVALENCE; FOCUS;
D O I
10.2147/OPTH.S208651
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the effect of induced astigmatic defocus on visual performance in pseudophakic eyes implanted with a small aperture, trifocal, or monofocal intraocular lens (IOL). Patients and methods: The study included 44 eyes with one of four types of IOL (IC-8 IOL (AcuFocus Inc., USA); FineVision (PhysIOL SA, Belgium); AT Lisa (Carl Zeiss AG, Germany); and enVista monofocal (Bausch & Lomb, USA). For astigmatic tolerance assessment, monocular distance visual acuity was measured with cylindrical lenses (power range=0.00-2.50 diopters (D) in 0.50 D increments) added to the subjects best-corrected distance manifest refraction. The assessment was repeated on three pre-determined axes (90 degrees, 180 degrees, and either 45 degrees or 135 degrees). The magnitude of astigmatic tolerance at each defocus step was assessed by taking the difference between logMAR visual acuity at the defocus step relative to that at 0.0 D (ie, no defocus condition). Results: Across all three axes, the reduction of mean monocular visual acuity at all defocus levels relative to no defocus was significantly smaller in IC-8 group compared to the other IOL groups. When the data was combined across all axes, the astigmatic tolerance of the IC-8 group was better than AT Lisa group from 0.50 D to 2.50 D and FineVision group from 0.50 D to 1.50 D (all P<0.05, ANOVA). The IC-8 group was better than the enVista group, but not significantly (P>0.05, ANOVA). Among individual orientations, statistically significant differences were seen between IC-8 IOLs and the other IOLs, with the largest difference being in the oblique axis. Astigmatic tolerance at all axes combined was 1.40 D for IC-8 IOL, 0.70 D for AT Lisa and FineVision, and 1.00 D for enVista IOLs. Conclusion: The small aperture IC-8 IOL showed greater tolerance to induced astigmatic defocus compared to trifocal and monofocal IOLs.
引用
收藏
页码:905 / 911
页数:7
相关论文
共 49 条
  • [1] Effect of residual astigmatism and defocus in eyes with trifocal intraocular lenses
    Rementeria-Capelo, Laureano A.
    Contreras, Ines
    Garcia-Perez, Jorge L.
    Blazquez, Vanesa
    Ruiz-Alcocer, Javier
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (06): : 679 - 684
  • [2] Peripheral aberrations of pseudophakic eyes implanted with an aspheric monofocal intraocular lens
    Alarcon, Aixa
    Rosen, Robert
    Draschl, Petra
    Hirnschall, Nino
    Van der Mooren, Marrie
    Piers, Patricia A.
    Findl, Oliver
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [3] Trifocal toric intraocular lenses in eyes with low amount of corneal astigmatism
    Paz Orts-Vila
    Salvador Aguilar-Córcoles
    Cristina Tello-Elordi
    María Ramos-Alzamora
    Robert Montés-Micó
    Pedro Ta?á-Rivero
    International Journal of Ophthalmology, 2020, (10) : 1567 - 1573
  • [4] Trifocal toric intraocular lenses in eyes with low amount of corneal astigmatism
    Orts-Vila, Paz
    Aguilar-Corcoles, Salvador
    Tello-Elordi, Cristina
    Ramos-Alzamora, Maria
    Montes-Mico, Robert
    Tana-Rivero, Pedro
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (10) : 1567 - 1573
  • [5] Small-aperture intraocular lens tolerance to induced astigmatism
    Ang, Robert Edward
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 1659 - 1664
  • [6] Investigation of Pupillary Responses in Healthy Eyes and Eyes Implanted with Multifocal or Monofocal Intraocular Lenses
    Miyata, Kohei
    Kobayakawa, Shinichiro
    CURRENT EYE RESEARCH, 2025,
  • [7] Toric intraocular lenses for astigmatism correction after keratoplasty in phakic and pseudophakic eyes
    Wan, Kelvin H.
    Chang, John S. M.
    Jhanji, Vishal
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (09): : 1078 - 1087
  • [8] An objective method to measure astigmatism tolerance with a small-aperture vs. monofocal intraocular lens
    Thomas, Eugenia Kao
    Lin, Ling
    Vilupuru, Srividhya
    Ang, Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [9] Comparison of visual function between phakic eyes and pseudophakic eyes with a monofocal intraocular lens
    Hayashi, Ken
    Yoshida, Motoaki
    Manabe, Shin-ichi
    Hayashi, Hideyuki
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (01): : 20 - 27
  • [10] THROUGH FOCUS IMAGE QUALITY OF EYES IMPLANTED WITH MONOFOCAL AND MULTIFOCAL INTRAOCULAR LENSES
    ARTAL, P
    MARCOS, S
    NAVARRO, R
    MIRANDA, I
    FERRO, M
    OPTICAL ENGINEERING, 1995, 34 (03) : 772 - 779