T2-weighted balanced SSFP imaging (T2-TIDE) using variable flip angles

被引:20
作者
Paul, Dominik [1 ]
Markl, Michael [1 ]
Fautz, Hans-Peter [1 ]
Hennig, Juergen [1 ]
机构
[1] Univ Hosp Freiburg, Dept Diagnost Radiol Med Phys, D-79106 Freiburg, Germany
关键词
steady-state free precession (SSFP); TrueFISP; TIDE; T-2-weighting; variable flip angles;
D O I
10.1002/mrm.20922
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new technique for acquiring T-2-weighted, balanced steady-state free precession (b-SSFP) images is presented. Based on the recently proposed transition into driven equilibrium (TIDE) method, T-2-TIDE uses a special flip angle scheme to achieve T-2-weighted signal decay during the transient phase. In combination with half-Fourier image acquisition, T-2-weighted images can be obtained using T-2-TIDE. Numerical simulations were performed to analyze the signal behavior of T-2-TIDE in comparison with TSE and b-SSFP. The results indicate identical signal evolution of T-2-TIDE and TSE during the transient phase. T-2-TIDE was used in phantom experiments, and quantitative ROI analysis shows a linear relationship between TSE and T-2-TIDE SNR values. T-2-TIDE was also applied to abdominal and head imaging on healthy volunteers. The resulting images were analyzed quantitatively and compared with standard T-2-weighted and standard b-SSFP methods. T-2-TIDE images clearly revealed T-2 contrast and less blurring compared to T-2-HASTE images. In combination with a magnetization preparation technique, STIR-weighted images were obtained. T.-TIDE is a robust technique for acquiring T-2-weighted images while exploiting the advantages of b-SSFP imaging, such as high signal-to-noise ratio (SNR) and short TFIs.
引用
收藏
页码:82 / 93
页数:12
相关论文
共 22 条
[1]   Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: Feasibility study [J].
Barkhausen, J ;
Quick, HH ;
Lauenstein, T ;
Goyen, M ;
Ruehm, SG ;
Laub, G ;
Debatin, JF ;
Ladd, ME .
RADIOLOGY, 2001, 220 (01) :252-256
[2]   Analysis and compensation of eddy currents in balanced SSFP [J].
Bieri, O ;
Markl, M ;
Scheffler, K .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (01) :129-137
[3]   STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE [J].
CARR, HY .
PHYSICAL REVIEW, 1958, 112 (05) :1693-1701
[4]  
Deimling M., 1994, PROC 2 ANN M SMR SAN, P495
[5]   3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries [J].
Deshpande, VS ;
Shea, SM ;
Laub, G ;
Simonetti, OP ;
Finn, JP ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :494-502
[6]   Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at .2 T [J].
Duerk, JL ;
Lewin, JS ;
Wendt, M ;
Petersilge, C .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :203-208
[7]  
Haacke EM, 1999, MAGNETIC RESONANCE I
[8]   Characterization and reduction of the transient response in steady-state MR imaging [J].
Hargreaves, BA ;
Vasanawala, SS ;
Pauly, JM ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :149-158
[9]   Optimization of signal behavior in the transition to driven equilibrium in steady-state free precession sequences [J].
Hennig, J ;
Speck, O ;
Scheffler, K .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (05) :801-809
[10]   Are TrueFISP images T2/T1-weighted? [J].
Huang, TY ;
Huang, IJ ;
Chen, CY ;
Scheffler, K ;
Chung, HW ;
Cheng, HC .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) :684-688