Optimization Method for Twin-Tunnel Complementary Ventilation Design and Its Energy Saving Effect

被引:3
作者
Chai, Lunlei [1 ]
Wang, Xing [1 ]
Han, Xingbo [1 ]
Xia, Yongxu [1 ]
Wang, Yongdong [1 ]
Lei, Ping [1 ]
机构
[1] Changan Univ, Sch Highway, Xian 710064, Shaanxi, Peoples R China
关键词
Energy utilization;
D O I
10.1155/2019/6301041
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Based on the compensation principle and optimization theory, an energy conservation optimization mode for twin-tunnels complementary ventilation design was proposed. And, compensation concept utilization in energy conservation of long tunnels ventilation was discussed. The energy consumption for long tunnels can be reduced significantly by remoulding longitudinal ventilation to complementary ventilation of single U-type mode or normal mode. The short-term and long-term ventilation systems of the Qingniling Tunnel, Dabieshan Tunnel, and Lianghekou Tunnel were redesigned using the optimization method, and the new scheme was compared to the original design in terms of ventilation effects, and energy consumption. In redesign, the energy consumption of short-term ventilation systems decreased 240 kW, 150 kW, and 390 kW, and energy efficiency increased by 40%, 50%, and 68.4%, respectively. In the long term, the numbers of those were 1185 kW, 1185kW, and 540 kW, and 42.5%, 58.09%, and 45%, while the pollutants concentration increased a little. The study can provide a reference for the energy efficient design of ventilation systems in long and extra-long highway tunnels.
引用
收藏
页数:19
相关论文
共 30 条
[1]   Simulation of airflow and pollution levels caused by severe traffic jam in a road tunnel [J].
Bari, S. ;
Naser, J. .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2010, 25 (01) :70-77
[2]  
Berner M., 1991, TUNNELS TUNNELLING I, V23
[3]   The influence of longitudinal ventilation systems on fires in tunnels [J].
Carvel, RO ;
Beard, AN ;
Jowitt, PW .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2001, 16 (01) :3-21
[4]  
Caserta A., 2000, AERODYNAMICS VENTILA
[5]   Complementary Ventilation Design Method for a Highway Twin-Tunnel Based on the Compensation Concept [J].
Chai, Lunlei ;
Wang, Xing ;
Han, Xingbo ;
Song, Jing ;
Lei, Ping ;
Xia, Yongxu ;
Wang, Yongdong .
MATHEMATICAL PROBLEMS IN ENGINEERING, 2018, 2018
[6]  
Chen F., 2000, APPL MECH REV, V53, P1161
[7]  
CHEN T, 2002, J WIND ENG IND AEROD, V73, P99
[8]   Longitudinal ventilation for smoke control in a tilted tunnel by scale modeling [J].
Chow, W. K. ;
Wong, K. Y. ;
Chung, W. Y. .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2010, 25 (02) :122-128
[9]   Numerical studies on evacuation design in a karaoke [J].
Chow, WK ;
Lui, GCH .
BUILDING AND ENVIRONMENT, 2002, 37 (03) :285-294
[10]   A numerical and experimental study of pollutant dispersion in a traffic tunnel [J].
Chung, Chung-Yi ;
Chung, Pei-Ling .
ENVIRONMENTAL MONITORING AND ASSESSMENT, 2007, 130 (1-3) :289-299