A 16 x 256 SPAD Line Detector With a 50-ps, 3-bit, 256-Channel Time-to-Digital Converter for Raman Spectroscopy

被引:40
作者
Nissinen, Ilkka [1 ]
Nissinen, Jan [1 ]
Keranen, Pekka [1 ]
Stoppa, David [2 ]
Kostamovaara, Juha [1 ]
机构
[1] Univ Oulu, Circuits & Syst Res Unit, Oulu 90014, Finland
[2] Fdn Bruno Kessler, I-38123 Povo, Italy
基金
芬兰科学院;
关键词
SPAD detector; Raman spectroscopy; time gating; FLUORESCENCE SUPPRESSION; REJECTION; ARRAY;
D O I
10.1109/JSEN.2018.2813531
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A 16 x 256 element single-photon avalanche diode array with a 256-channel, 3-bit on-chip time-to-digital converter (TDC) has been developed for fluorescence-suppressed Raman spectroscopy. The circuit is fabricated in 0.35 mu m high-voltage CMOS technology and it allows a measurement rate of 400 kframe/s. In order to be able to separate the Raman and fluorescence photons even in the presence of the unavoidable timing skew of the timing signals of the TDC, the time-of-arrival of every detected photon is recorded with high time resolution at each spectral point with respect to the emitted short and intensive laser pulse (similar to 150 ps). The dynamic range of the TDC is set so that no Raman photon is lost due to the timing skew, and thus the complete time history of the detected photons is available at each spectral point. The resolution of the TDC was designed to be adjustable from 50 ps to 100 ps. The error caused by the timing skew and the residual variation in the resolution of the TDC along the spectral points is mitigated utilizing a calibration measurement from reference sample with known smooth fluorescence spectrum. As a proof of concept, the Raman spectrum of sesame seed oil, having a high fluorescence-to-Raman ratio and a short fluorescence lifetime of 1.9 ns, was successfully recorded.
引用
收藏
页码:3789 / 3798
页数:10
相关论文
共 27 条
  • [1] Non-invasive in vivo determination of the carotenoids beta-carotene and lycopene concentrations in the human skin using the Raman spectroscopic method
    Darvin, ME
    Gersonde, I
    Meinke, M
    Sterry, W
    Lademann, J
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2005, 38 (15) : 2696 - 2700
  • [2] Fluorescence rejection in resonance Raman spectroscopy using a picosecond-gated intensified charge-coupled device camera
    Efremov, Evtim V.
    Buijs, Joost B.
    Gooijer, Cees
    Ariese, Freek
    [J]. APPLIED SPECTROSCOPY, 2007, 61 (06) : 571 - 578
  • [3] Erdogan A. T., 2017, P S VLSI CIRC KYOT J, P292
  • [4] Prospects for in vivo Raman spectroscopy
    Hanlon, EB
    Manoharan, R
    Koo, TW
    Shafer, KE
    Motz, JT
    Fitzmaurice, M
    Kramer, JR
    Itzkan, I
    Dasari, RR
    Feld, MS
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (02) : R1 - R59
  • [5] Short-wave infrared excited spatially offset Raman spectroscopy (SORS) for through-barrier detection
    Hopkins, Rebecca J.
    Pelfrey, Suzanne H.
    Shand, Neil C.
    [J]. ANALYST, 2012, 137 (19) : 4408 - 4410
  • [6] Khalil OS, 1999, CLIN CHEM, V45, P165
  • [7] Fluorescence suppression in Raman spectroscopy using a time-gated CMOS SPAD
    Kostamovaara, Juha
    Tenhunen, Jussi
    Kogler, Martin
    Nissinen, Ilkka
    Nissinen, Jan
    Keranen, Pekka
    [J]. OPTICS EXPRESS, 2013, 21 (25): : 31632 - 31645
  • [8] Time-resolved spectroscopy at 19,000 lines per second using a CMOS SPAD line array enables advanced biophotonics applications
    Kufcsak, A.
    Erdogan, A.
    Walker, R.
    Ehrlich, K.
    Tanner, M.
    Megia-Fernandez, A.
    Scholefield, E.
    Emanuel, P.
    Dhaliwal, K.
    Bradley, M.
    Henderson, R. K.
    Krstajic, N.
    [J]. OPTICS EXPRESS, 2017, 25 (10): : 11103 - 11123
  • [9] L'Heureux M, 2015, SPECTROSCOPY-US, V30, P44
  • [10] Raman spectroscopy in the analysis of food and pharmaceutical nanomaterials
    Li, Ying-Sing
    Church, Jeffrey S.
    [J]. JOURNAL OF FOOD AND DRUG ANALYSIS, 2014, 22 (01) : 29 - 48