Influence of SOLT Calibration Standards on Multiport VNA S-Parameter Measurements

被引:0
|
作者
Zhao, Wei [1 ]
Xiao, Jiankang [1 ]
Qin, Hongbo [1 ]
机构
[1] Xidian Univ, Sch Elect & Mech Engn, Xian 710071, Peoples R China
关键词
UNCERTAINTIES;
D O I
10.2528/PIER13122303
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For the GSOLT calibration algorithm of n-port vector network analyzers (VNA), the sensitivity coefficients for the S-parameters of the n-port device under test (DUT) are developed as functions of the S-parameter deviations of SOLT standards. By introducing the generalized flow graph of the 3n-term error model, analytic formulas for the S-parameter deviations of the n-port DUT with respect to the error terms have been deduced. In addition, expressions for the deviations of the error terms in regard to the nonideal calibration elements are given by a series of matrix operations. Finally, the analytic expressions of the sensitivity coefficients are concluded, which can be used for establishing the type-B uncertainty budget for S-parameter measurements.
引用
收藏
页码:303 / 318
页数:16
相关论文
共 50 条
  • [21] VNA Tools II: S-parameter uncertainty calculation
    Wollensack, Michael
    Hoffmann, Johannes
    Ruefenacht, Juerg
    Zeier, Markus
    2012 79TH ARFTG MICROWAVE MEASUREMENT CONFERENCE (ARFTG), 2012,
  • [22] Influence of non-ideal line-reflect-match calibration standards on vector network analyzer S-parameter measurements
    Zhao, Wei
    Cheng, Chunyue
    Yang, Chao
    Xiao, Jiankang
    Wang, Yibang
    Huo, Ye
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2023, 17 (06) : 257 - 268
  • [23] Multiport Network S-parameter Restoration and Calibration with 2-port Network Analyzer
    Chen, Yin
    You, Fei
    Ma, Mingming
    Guo, Haoye
    Wang, Yu
    Li, Jiachao
    Wu, Tao
    Qian, Ting
    He, Songbai
    2022 INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY (ICMMT), 2022,
  • [24] Accurate Measurement Standards and Calibration Techniques for S-parameter Measurements in Coaxial Line System at Millimeter Wave Frequency
    Horibe, M.
    Kishikawa, R.
    PROCEEDINGS OF PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS 2012), 2012, : 943 - 946
  • [25] Traceability to national standards for S-parameter measurements in waveguide at 1.1 THz
    Horibe, Masahiro
    Kishikawa, Ryoko
    CPEM Digest (Conference on Precision Electromagnetic Measurements), 2012, : 254 - 255
  • [26] CALIBRATION OF MICROWAVE NETWORK ANALYZER FOR COMPUTER CORRECTED S-PARAMETER MEASUREMENTS
    DASILVA, EF
    MCPHUN, MK
    ELECTRONICS LETTERS, 1973, 9 (06) : 126 - 128
  • [27] Multiport S-Parameter and T-Parameter Conversion With Symmetry Extension
    Frei, James
    Cai, Xiao-Ding
    Muller, Stephen
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2008, 56 (11) : 2493 - 2504
  • [28] On peculiarities of S-parameter measurements
    Rolain, Yves
    Van Moer, Wendy
    Jargon, Jeffrey A.
    DeGroot, Donald C.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (05) : 1967 - 1972
  • [29] Performing S-parameter measurements
    Sundberg, G
    MICROWAVES & RF, 2001, 40 (06) : 99 - 100
  • [30] Influence of Nonideal Calibration Items on S-Parameter Uncertainties Applying the SOLR Calibration Method
    Stumper, Ulrich
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (04) : 1158 - 1163