Image quality and dose management in digital radiography: A new paradigm for optimisation

被引:44
作者
Busch, HP
Faulkner, K
机构
[1] Qual Assurance Reference Ctr, Wallsend NE28 9ND, Tyne & Wear, England
[2] Krakenhaus Barmherzigen Brudder, Dept Radiol, Trier, Germany
关键词
D O I
10.1093/rpd/nci728
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The advent of digital imaging in radiology, combined with the explosive growth of technology, has dramatically improved imaging techniques. This has led to the expansion of diagnostic capabilities, both in terms of the number of procedures and their scope. Throughout the world, film/screen radiography systems are being rapidly replaced with digital systems. Many progressive medical institutions have acquired, or are considering the purchase of computed radiography systems with strorage phosphor plates or direct digital radiography systems with flat panel detectors. However, unknown to some users, these devices offer a new paradigm of opportunity and challenges. Images can be obtained at a lower dose owing to the higher detective quantum efficiency (DQE). These fundamental differences in comparison to conventional film/screens necessitate the development of new strategies for dose and quality optimisations. A set of referral criteria based upon three dose levels is proposed.
引用
收藏
页码:143 / 147
页数:5
相关论文
共 19 条
[1]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[2]  
BUSCH HP, 1995, RADIAT PROT DOSIM, V57, P139
[3]  
BUSCH HP, 1995, RADIAT PROT DOSIM, V80, P61
[4]  
BUSCH HP, 2002, B0561SS1013 ECR
[5]  
BUSCH S, 2002, THESIS KLINIKUM MANN
[6]   Digital chest radiography with a solid-state flat-panel X-ray detector Contrast-detail evaluation with processed images printed on film hard copy [J].
Chotas, HG ;
Ravin, CE .
RADIOLOGY, 2001, 218 (03) :679-682
[7]  
*COMM EUR COMM REF, RAD PROT, V118
[8]   Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography [J].
Floyd, CE ;
Warp, RJ ;
Dobbins, JT ;
Chotas, HG ;
Baydush, AH ;
Vargas-Voracek, R ;
Ravin, CE .
RADIOLOGY, 2001, 218 (03) :683-688
[9]   Image quality vs radiation dose for a flat-panel amorphous silicon detector: a phantom study [J].
Geijer, H ;
Beckman, KW ;
Andersson, T ;
Persliden, J .
EUROPEAN RADIOLOGY, 2001, 11 (09) :1704-1709
[10]   Digital radiography with a large-scale electronic flat-panel detector vs screen-film radiography: observer preference in clinical skeletal diagnostics [J].
Hamers, S ;
Freyschmidt, J ;
Neitzel, U .
EUROPEAN RADIOLOGY, 2001, 11 (09) :1753-1759