摘要
A Love-wave device and a PDMS microfluidic chip have been developed in order to measure immunoreactions in liquid media, operating in dynamic mode (continuous flow-through). The obtained results with the above system for the detection of rabbit immunoglobulin by means of an antibody of goat anti-rabbit have been compared with those obtained by the most used acoustic wave device, the quartz crystal microbalance (QCM), which has worked in static mode. It has been demonstrated once again that QCM is an excellent tool as an immunosensor, although the Love-wave device is a good alternative due to its higher sensitivity. The dynamic mode improves the response time and the limit of detection. In addition, the use of microchannels has allowed working with a small sample volume for a long period of time in dynamic mode. On the other hand, a secondary antibody conjugated with gold nanoparticles has been used as a different method to measure the desired concentrations of antigens, obtaining in this case, a greater frequency shift. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:123 / 129
页数:7
相关论文
共 32 条
[1]   HIV SEROLOGY USING PIEZOELECTRIC IMMUNOSENSORS [J].
ABERL, F ;
WOLF, H ;
KOSSLINGER, C ;
DROST, S ;
WOIAS, P ;
KOCH, S .
SENSORS AND ACTUATORS B-CHEMICAL, 1994, 18 (1-3) :271-275
[2]  
[Anonymous], 2008, ANN ICRP
[3]   Thioglycolic acid grafted onto silica gel and its properties in relation to extracting cations from ethanolic solution determined by calorimetric technique [J].
Arakaki, LNH ;
Espínola, JGP ;
da Fonseca, MG ;
de Oliveira, SF ;
de Sousa, AN ;
Arakaki, T ;
Airoldi, C .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2004, 273 (01) :211-217
[4]   Evaluation of antibody immobilization methods for piezoelectric biosensor application [J].
Babacan, S ;
Pivarnik, P ;
Letcher, S ;
Rand, AG .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (11-12) :615-621
[5]  
BALLANTINE DS, 1997, ACOUSTIC WAVE SENSOR, pCH3
[6]   Ultrasensitive magnetic biosensor for homogeneous immunoassay [J].
Chemla, YR ;
Crossman, HL ;
Poon, Y ;
McDermott, R ;
Stevens, R ;
Alper, MD ;
Clarke, J .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (26) :14268-14272
[7]   Use of a channel biosensor for the assay of paralytic shellfish toxins [J].
Cheun, BS ;
Loughran, M ;
Hayashi, T ;
Nagashima, Y ;
Watanabe, E .
TOXICON, 1998, 36 (10) :1371-1381
[8]   Tapered optical fiber biosensor for the detection of anti-gliadin antibodies [J].
Corres, J. M. ;
Matias, I. R. ;
Bravo, J. ;
Arregui, F. J. .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 135 (01) :166-171
[9]   Selective laser photo-thermal therapy of epithelial carcinoma using anti-EGFR antibody conjugated gold nanoparticles [J].
El-Sayed, Ivan H. ;
Huang, Xiaohua ;
El-Sayed, Mostafa A. .
CANCER LETTERS, 2006, 239 (01) :129-135
[10]   Gold screen-printed-based impedimetric immunobiosensors for direct and sensitive Escherichia coli quantisation [J].
Escamilla-Gomez, Vanessa ;
Campuzano, Susana ;
Pedrero, Maria ;
Pingarron, Jose M. .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (11) :3365-3371