摘要
The accuracy of superficial dose calculations for breast cancer treatments with Volumetric Modulated Arc Therapy (VMAT) is of major importance. For target volumes close to the surface, the inverse dosimetric planning can lead to very high fluences in the build-up region to properly cover the volume to be treated. Various radiotherapy modalities are currently used in parallel with additional protocols to enable a better control on the dose delivery (bolus, target volume margins). One of the difficulties currently facing medical physicists is the lack of available tools to test the impact of these different solutions on the superficial dose distribution. We present a new open source toolkit to assist medical physicists in evaluating the 3D distributions of superficial dose in VMAT breast cancer treatments. This tool is based on the GATE Monte Carlo software, a Geant4 application dedicated to medical physics. A set of macros has been developed to simulate in an easy way a full VMAT plan from the information available in the DICOM-RT files (image, plan, structure and dose). The toolkit has been tested on a 6 MV Varian NovalisTx (TM) accelerator. The paper presents a precise comparison of 3D surface dose distributions from experimental measurements (EBT3 films), TPS (Varian Eclipse) and Monte Carlo simulation (GATE). The comparison made it possible to highlight both the TPS biases for the surface dose calculation and the good performances of the developed toolkit. The simulation of surface dose distributions on a real patient has also been performed to illustrate the potential clinical applications.
引用
收藏
页码:112 / 117
页数:6
相关论文
共 32 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   Characteristics of flattening filter free beams at low monitor unit settings [J].
Akino, Yuichi ;
Ota, Seiichi ;
Inoue, Shinichi ;
Mizuno, Hirokazu ;
Sumida, Iori ;
Yoshioka, Yasuo ;
Isohashi, Fumiaki ;
Ogawa, Kazuhiko .
MEDICAL PHYSICS, 2013, 40 (11)
[3]   Superficial doses in breast cancer radiotherapy using conventional and IMRT techniques: A film-based phantom study [J].
Almberg, Sigrun Saur ;
Lindmo, Tore ;
Frengen, Jomar .
RADIOTHERAPY AND ONCOLOGY, 2011, 100 (02) :259-264
[4]   Monte Carlo simulations in radiotherapy dosimetry [J].
Andreo, Pedro .
RADIATION ONCOLOGY, 2018, 13
[5]   Real-time detection of fast and thermal neutrons in radiotherapy with CMOS sensors [J].
Arbor, Nicolas ;
Higueret, Stephane ;
Elazhar, Halima ;
Combe, Rodolphe ;
Meyer, Philippe ;
Dehaynin, Nicolas ;
Taupin, Florence ;
Husson, Daniel .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (05) :1920-1934
[6]   Image-guided volumetric modulated arc therapy for breast cancer: a feasibility study and plan comparison with three-dimensional conformal and intensity-modulated radiotherapy [J].
Badakhshi, H. ;
Kaul, D. ;
Nadobny, J. ;
Wille, B. ;
Sehouli, J. ;
Budach, V. .
BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1032)
[7]   Superficial dose evaluation of four dose calculation algorithms [J].
Cao, Ying ;
Yang, Xiaoyu ;
Yang, Zhen ;
Qiu, Xiaoping ;
Lv, Zhiping ;
Lei, Mingjun ;
Liu, Gui ;
Zhang, Zijian ;
Hu, Yongmei .
RADIATION PHYSICS AND CHEMISTRY, 2017, 137 :23-28
[8]   Superficial dose distribution in breast for tangential radiation treatment, Monte Carlo evaluation of Eclipse algorithms in case of phantom and patient geometries [J].
Chakarova, Roumiana ;
Gustafsson, Magnus ;
Back, Anna ;
Drugge, Ninni ;
Palm, Asa ;
Lindberg, Andreas ;
Berglund, Mattias .
RADIOTHERAPY AND ONCOLOGY, 2012, 102 (01) :102-107
[9]   Helical Tomotherapy for Inoperable Breast Cancer: A New Promising Tool [J].
Chira, Ciprian ;
Kirova, Youlia M. ;
Liem, Xavier ;
Campana, Francois ;
Peurien, Dominique ;
Amessis, Malika ;
Fournier-Bidoz, Nathalie ;
Pierga, Jean-Yves ;
Dendale, Remi ;
Bey, Pierre ;
Fourquet, Alain .
BIOMED RESEARCH INTERNATIONAL, 2013, 2013
[10]   Monte Carlo implementation, validation, and characterization of a 120 leaf MLC [J].
Fix, Michael K. ;
Volken, Werner ;
Frei, Daniel ;
Frauchiger, Daniel ;
Born, Ernst J. ;
Manser, Peter .
MEDICAL PHYSICS, 2011, 38 (10) :5311-5320