Intramedullary nails with two lag screws

被引:24
作者
Brown, CJ [1 ]
Wang, CJ
Yettram, AL
Procter, P
机构
[1] Brunel Univ, Dept Mech Engn, Uxbridge UB8 3PH, Middx, England
[2] Stryker Trauma, CH-1228 Geneva, Switzerland
关键词
D O I
10.1016/j.clinbiomech.2004.01.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To investigate the structural integrity of intramedullary nails with two lag screws, and to give guidance to orthopaedic surgeons in the choice of appropriate devices. Design. Alternative designs of the construct are considered, and the use of a slotted upper lag screw insertion hole is analysed. Background. Intramedullary fixation devices with a single lag screw have been known to fail at the lag screw insertion hole. Using two lag screws is considered. It has also been proposed to use a slot in the nail for the upper lag screw to prevent the upper lag screw from sticking. Methods. Bending and torsion load cases are analysed using finite element method. Consideration of both load conditions is essential. Results. The results present the overall stiffness of the assembly, the load sharing between lag screws, and the possibility for cutout to occur. Conclusions. While the slot for the upper lag screw might be advantageous with regard to the stresses in the lag screws, it could be detrimental for cut-out occurring adjacent to the lag screws.
引用
收藏
页码:519 / 525
页数:7
相关论文
共 9 条
[1]  
ASCHE G, 1999, GAMMA LOCKING NAIL 1, P126
[2]  
DUBBELD J, 2000, HIP FRACT STAT ART M
[3]   Morphological study of the proximal femur: a new method of geometrical assessment using 3-dimensional reverse engineering [J].
Mahaisavariya, B ;
Sitthiseripratip, K ;
Tongdee, T ;
Bohez, ELJ ;
Vander Sloten, J ;
Oris, P .
MEDICAL ENGINEERING & PHYSICS, 2002, 24 (09) :617-622
[4]  
MCRAE R, 1996, PRACTICAL FRACTURE T
[5]   The cost and implications of reoperation after surgery for fracture of the hip [J].
Palmer, SJ ;
Parker, MJ ;
Hollingworth, W .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (06) :864-866
[6]  
Randle JA, 1999, CAN J SURG, V42, P384
[7]   Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95° screw-plate -: A prospective, randomized study [J].
Sadowski, C ;
Lübbeke, A ;
Saudan, M ;
Riand, N ;
Stern, R ;
Hoffmeyer, P .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (03) :372-381
[8]   Biomechanical evaluation of the proximal femoral nail [J].
Schipper, IB ;
Bresina, S ;
Wahl, D ;
Linke, B ;
van Vugt, IAB ;
Schneider, E .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (405) :277-286
[9]   Intramedullary femoral nails: one or two lag screws? A preliminary study [J].
Wang, CJ ;
Brown, CJ ;
Yettram, AL ;
Procter, P .
MEDICAL ENGINEERING & PHYSICS, 2000, 22 (09) :613-624