Numerical and experimental investigation on the performance of a photovoltaic thermal collector with parallel plate flow channel under different operating conditions in Malaysia

被引:155
作者
Nahar, Afroza [1 ,2 ]
Hasanuzzaman, M. [1 ]
Rahim, N. A. [1 ,3 ]
机构
[1] Univ Malaya, Wisma R&D, UMPEDAC, Level 4, Kuala Lumpur 59990, Malaysia
[2] Univ Malaya, Inst Grad Studies, Kuala Lumpur 50603, Malaysia
[3] King Abdulaziz Univ, Renewable Energy Res Grp, Jeddah 21589, Saudi Arabia
关键词
Solar energy; Photovoltaic thermal collector; 3D numerical model; Finite element method; Outdoor experiment; Parallel plate flow channel; PV/T SOLAR COLLECTORS; HEATING-SYSTEM; HYBRID SYSTEM; MODULE; MODEL; WATER; POWER;
D O I
10.1016/j.solener.2017.01.041
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Solar energy is universally accepted as the most potential alternative power source due to its inexhaustible availability, diverse conversion technology and environmental friendly nature. Hybrid photovoltaic-thermal (PV/T) system is an optimized solar energy system that produces electricity and thermal energy simultaneously from the same physical profile. The basic problem of the hybrid collector is the removal and transfer of heat in an efficient way. In this article, PV/T system with a novel design of thermal collector excluding the absorber plate has been introduced to resolve the above mentioned problem. A parallel plate thermal collector without absorber plate has been attached directly to the PV module backside by means of thermal paste only and the performance of the PV/T is evaluated numerically and validated by experimental data for different operating conditions. A 3D numerical analysis of the PV/T system has been performed using finite element method (FEM) based software COMSOL Multiphysics. The outdoor experimental investigation has been done under the typical climatic condition of Malaysia. Elevation head of water has been employed to ensure passive cooling of PV module. The numerical simulation results are found in well agreement with those of experimental measurements. Thermal performance of PV/T without absorber plate is found almost as good as that with absorber plate. The numerical and experimental values for maximum overall efficiency of the PV/T system was found 84.4% and 80%, respectively under the irradiation level at 1000 W/m(2) with both inlet and ambient temperatures being 34 degrees C. The developed simulation model can be extended for other designs of thermal collector using different materials. (C) 2017 Published by Elsevier Ltd.
引用
收藏
页码:517 / 528
页数:12
相关论文
共 42 条
[1]   Experimental and numerical investigation of a flat-plate solar collector [J].
Alvarez, A. ;
Cabeza, O. ;
Muniz, M. C. ;
Varela, L. M. .
ENERGY, 2010, 35 (09) :3707-3716
[2]  
[Anonymous], 2016, INT ENERGY OUTLOOK 2
[3]   Energy supply, its demand and security issues for developed and emerging economies [J].
Asif, M. ;
Muneer, T. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2007, 11 (07) :1388-1413
[4]  
Bakker M., 2002, PV TECHN EN C EXH RO
[5]   Comparisons of MPPT performances of isolated and non-isolated DC-DC converters by using a new approach [J].
Basoglu, Mustafa Engin ;
Cakir, Bekir .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 60 :1100-1113
[6]   Cooling of a photovoltaic module with temperature controlled solar collector [J].
Ceylan, Ilhan ;
Gurel, Ali Etem ;
Demircan, Husamettin ;
Aksu, Bahri .
ENERGY AND BUILDINGS, 2014, 72 :96-101
[7]   Passive cooling of standalone flat PV module with cotton wick structures [J].
Chandrasekar, M. ;
Suresh, S. ;
Senthilkumar, T. ;
Karthikeyana, M. Ganesh .
ENERGY CONVERSION AND MANAGEMENT, 2013, 71 :43-50
[8]   Hybrid photovoltaic-thermosyphon water heating system for residential application [J].
Chow, TT ;
He, W ;
Ji, J .
SOLAR ENERGY, 2006, 80 (03) :298-306
[9]   Performance analysis of photovoltaic-thermal collector by explicit dynamic model [J].
Chow, TT .
SOLAR ENERGY, 2003, 75 (02) :143-152
[10]   DESIGN CONSIDERATIONS FOR FLAT-PLATE-PHOTOVOLTAIC THERMAL COLLECTORS [J].
COX, CH ;
RAGHURAMAN, P .
SOLAR ENERGY, 1985, 35 (03) :227-241