The Impact of Circuit Variables on the Starting Performance of Field-Aligned Starting

被引:1
作者
Baguley, Craig A. [1 ]
Madawala, Udaya K. [1 ]
机构
[1] Univ Auckland, Dept Elect & Comp Engn, Auckland 1142, New Zealand
关键词
Energy conversion; induction motors; parameter estimation; transient analysis; INDUCTION-MOTOR; OPERATION;
D O I
10.1109/TIE.2009.2017565
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Field-aligned starting (FAS) is a new technique for starting three-phase cage induction motors on either three- or single-phase supply lines with minimal inrush currents. FAS generates a high impulselike torque to start the motor that is independent of the mains supply, before connecting the already spinning motor to the mains supply. In contrast to conventional starting techniques, FAS imposes higher than normal/rated voltage and current conditions on the machine at starting, and as such, the transient performance of EAS operated motors is complex in nature and largely governed by a number of key circuit variables, the values of which are critical for an efficient and economical design of FAS. A detailed insight into the influence of these key parameters on transient performance during startup is essential to avoid time consuming and inefficient trial and error design methods currently utilized in FAS designs. This paper addresses this need through the investigation of both the functionality and the extent of impact of the key variables on the starting performance of EAS. A transient model is utilized, and both experimental and simulated results suggest that, for a given set of circuit components, the proper selection of variable values is critical to achieve the best possible performance at startup.
引用
收藏
页码:2067 / 2075
页数:9
相关论文
共 22 条
[1]   Complete parameter identification of large induction machines from no-load acceleration-deceleration tests [J].
Babau, Radu ;
Boldea, Ion ;
Miller, T. J. E. ;
Muntean, Nicolae .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (04) :1962-1972
[2]  
BAGULEY CA, 2007, P IEEE EL MACH DRIV, V2, P1252
[3]   Performance analysis of an asymmetrical phase-converter-fed induction motor [J].
Biswas, SK ;
Chakraborty, C ;
Basak, B ;
Sen Gupta, DP .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (05) :1049-1058
[4]  
Boldea I, 2002, ELECTR POWER ENGN SE, pNIL_3
[5]  
BOYS JT, 2003, Patent No. 509552
[6]   Single-phase operation of a three-phase induction generator with the smith connection [J].
Chan, TF ;
Lai, LL .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2002, 17 (01) :47-54
[7]   OPERATION OF 3 PHASE INDUCTION-MOTORS CONNECTED TO ONE PHASE SUPPLY [J].
DEOLIVEIRA, SEM .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1990, 5 (04) :713-718
[8]  
FITZGERALD AE, 1992, ELECT MACH
[9]   Voltage sag effects on sensitive equipment due to starting cycles of induction motor [J].
Gomez, J.C. ;
Morcos, M.M. .
IEEE Power Engineering Review, 2002, 22 (08) :51-52
[10]  
GOMEZ JC, 2001, IEEE IAS ANN M SEP 3, V2, P1196