Postoperative Outcomes of Anophthalmic Socket Reconstruction Using an Autologous Buccal Mucosa Graft

被引:12
作者
Kim, Chang Yeom [1 ]
Woo, Young Jae [1 ]
Lee, Sang Yeul [1 ]
Yoon, Jin Sook [1 ]
机构
[1] Yonsei Univ, Coll Med, Dept Ophthalmol, Inst Vis Res, Seoul 120752, South Korea
关键词
Anophthalmic socket; buccal mucosa; graft; reconstruction; socket contracture; HARVEST SITE; MORBIDITY; DERMIS; MANAGEMENT;
D O I
10.1097/SCS.0000000000000807
中图分类号
R61 [外科手术学];
学科分类号
摘要
Socket contracture is one of the most common and difficult problems in anophthalmic patients. This study intended to evaluate postoperative outcomes of anophthalmic socket reconstruction using an autologous buccal mucosa graft in patients with socket contracture. Medical records and photographs of 44 anophthalmic patients who underwent socket reconstruction surgery using an autologous buccal mucosa graft were reviewed retrospectively. The time necessary for the graft surface to be completely vascularized was assessed, and fornix depth was measured before and 6 months after surgery. Postoperative cosmetic and functional outcomes were evaluated, and the factors that influence postoperative outcomes were investigated. The surgery was performed without any significant complications, and the patients only complained of oral discomfort within 1 week. The graft surface was fully vascularized about 1.1 months after surgery. Mean fornix depth after surgery was significantly deeper than that before surgery (9.1 mm, about 68.2% of the vertical size of the implanted graft). Preoperatively, 50.0% of the patient had cosmetic grades 1 and 2; however, 63.6% of the patients achieved grade 4, and 93.2% had higher than grade 3 after surgery. In functional outcomes, 86.4% of the patients presented functional success. Graft recontracture occurred in only 2 patients. Preoperative severe socket contracture was a factor associated with worse cosmetic outcome (P = 0.001). An autologous buccal mucosa can be a safe and effective graft material for the reconstruction of a contracted socket.
引用
收藏
页码:1171 / 1174
页数:4
相关论文
共 26 条
  • [1] Evaluation of amniotic membrane grafting in the reconstruction of contracted socket
    Bajaj, MS
    Pushker, N
    Singh, KK
    Chandra, M
    Ghose, S
    [J]. OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2006, 22 (02) : 116 - 120
  • [2] Oral Mucosal Graft to Correct Lid Margin Pathologic Features in Cicatricial Ocular Surface Diseases
    Fu, Yao
    Liu, Jingbo
    Tseng, Scheffer C. G.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 152 (04) : 600 - 608
  • [3] The use of AlloDerm for the correction of nasal contour deformities
    Gryskiewicz, JM
    Rohrich, RJ
    Reagan, BJ
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2001, 107 (02) : 561 - 570
  • [4] GUBERINA C, 1983, ARCH OPHTHALMOL-CHIC, V101, P1586
  • [5] Hashikawa K, 2007, PLAST RECONSTR SURG, V119, P2182, DOI 10.1097/01.prs.0000260706.07368.f1
  • [6] Assessment of the perfusion and morbidity of the buccal mucosal donor site for grafting of urethral strictures
    Hoelzle, Frank
    Mitchell, David A.
    Rau, Andrea
    Palisaar, Jueri
    Loeffelbein, Denys J.
    Noldus, Joachim
    Hoheisel, Anne
    Muecke, Thomas
    Kesting, Marco
    Wolff, Klaus-Dietrich
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2012, 40 (01) : 47 - 50
  • [7] The outcome of oral mucosal grafts to the orbit: a three-and-a-half-year study
    Jones, EJB
    Nunes, E
    [J]. BRITISH JOURNAL OF PLASTIC SURGERY, 2002, 55 (02): : 100 - 104
  • [8] Measurement of fornix depth and area: a novel method of determining the severity of fornix shortening
    Kawakita, T.
    Kawashima, M.
    Murat, D.
    Tsubota, K.
    Shimazaki, J.
    [J]. EYE, 2009, 23 (05) : 1115 - 1119
  • [9] Amniotic Membrane Transplantation Versus Mucous Membrane Grafting in Anophthalmic Contracted Socket
    Kumar, Sushil
    Sugandhi, Pallavi
    Arora, Ritu
    Pandey, Pramod Kumar
    [J]. ORBIT-AN INTERNATIONAL JOURNAL ON ORBITAL DISORDERS AND FACIAL RECONSTRUCTIVE SURGERY, 2006, 25 (03): : 195 - 203
  • [10] Lukats Olga, 2002, Orbit, V21, P125