Heart-Cut Two-Dimensional Countercurrent Chromatography with a Single Instrument

被引:24
作者
Englert, Michael [1 ]
Brown, Leslie [2 ]
Vetter, Walter [1 ]
机构
[1] Univ Hohenheim, Inst Food Chem 170b, D-70599 Stuttgart, Germany
[2] AECS QuikPrep Ltd, London WC1 6HQ, England
关键词
NATURAL-PRODUCTS; SOLVENT SYSTEMS; SEPARATION;
D O I
10.1021/acs.analchem.5b02859
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Countercurrent chromatography (CCC) is a separation technique based on the liquid liquid partitioning of compounds between the two phases of a biphasic solvent system. Limitations in the separation efficiency and peak capacity of one-dimensional (1D) CCC often result in insufficiently resolved peaks. Therefore, partially resolved peak fractions have to be rechromatographed in order to improve the yield and purity. Additional solvent evaporation steps can be circumvented by the application of two-dimensional CCC (2D CCC). Existing 2D CCC configurations are based on the linking of two CCC instruments which are not readily available in every laboratory. In this study, we introduce a technical improvement which allows performing multiple heart-cuts and 2D CCC separations with one instrument which has up to four independent coils, one pump, and one detector. For this purpose, we modified a commercially available CCC system by the addition of three six-port selection valves and a T-piece. The applicability of the 2D CCC system was shown under overloading conditions with eight alkyl hydroxybenzoates with nonideal conditions. We used two solvent systems which were hydrodynamically compatible and which showed different selectively characteristics with regard to the compounds. Four unresolved compounds in the first dimension were baseline resolved by means of the heart-cut technique, in which between 4 and 9 mL of the flow from coil 1 was transferred to coil 2. Three successive heart-cuts were performed that led to baseline resolution of unresolved compounds in the first dimension. The obtained recovery rates were 94-100%, and the purities of the compounds as determined by GC/MS were 90-100%.
引用
收藏
页码:10172 / 10177
页数:6
相关论文
共 14 条
[1]   Elution-extrusion countercurrent chromatography. Use of the liquid nature of the stationary phase to extend the hydrophobicity window [J].
Berthod, A ;
Ruiz-Angel, MJ ;
Carda-Broch, S .
ANALYTICAL CHEMISTRY, 2003, 75 (21) :5886-5894
[2]   COUNTERCURRENT CHROMATOGRAPHY IN ANALYTICAL CHEMISTRY (IUPAC Technical Report) [J].
Berthod, Alain ;
Maryutina, Tatyana ;
Spivakov, Boris ;
Shpigun, Oleg ;
Sutherland, Ian A. .
PURE AND APPLIED CHEMISTRY, 2009, 81 (02) :355-387
[3]   Solvent systems with n-hexane and/or cyclohexane in countercurrent chromatography-Physico-chemical parameters, and their impact on the separation of alkyl hydroxybenzoates [J].
Englert, Michael ;
Vetter, Walter .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1342 :54-62
[4]   Countercurrent Separation of Natural Products: An Update [J].
Friesen, J. Brent ;
McAlpine, James B. ;
Chen, Shao-Nong ;
Pauli, Guido F. .
JOURNAL OF NATURAL PRODUCTS, 2015, 78 (07) :1765-1796
[5]   GUESS - A generally useful estimate of solvent systems in CCC [J].
Friesen, JB ;
Pauli, GF .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (17) :2777-2806
[6]   Multidimensional separations in the pharmaceutical arena [J].
Guttman, A ;
Varoglu, M ;
Khandurina, J .
DRUG DISCOVERY TODAY, 2004, 9 (03) :136-144
[7]   Two-dimensional counter-current chromatography: 1st Traditional counter-current chromatography, 2nd acid-base elution counter-current chromatography [J].
Hu, Ruilin ;
Dai, Xiaojing ;
Xu, Xia ;
Sun, Cuirong ;
Pan, Yuanjiang .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (36) :6085-6091
[8]   Golden rules and pitfalls in selecting optimum conditions for high-speed counter-current chromatography [J].
Ito, Y .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1065 (02) :145-168
[9]   Effective two-dimensional counter-current chromatographic method for simultaneous isolation and purification of oridonin and ponicidin from the crude extract of Rabdosia rubescens [J].
Lu, Yanbin ;
Sun, Cuirong ;
Liu, Rui ;
Pan, Yuanjiang .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1146 (01) :125-130
[10]   New advances in countercurrent chromatography and centrifugal partition chromatography: focus on coupling strategy [J].
Michel, Thomas ;
Destandau, Emilie ;
Elfakir, Claire .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (04) :957-969