Real-Time Monitoring of Oxidative Burst from Single Plant Protoplasts Using Microelectrochemical Sensors Modified by Platinum Nanoparticles

被引:33
作者
Ai, Feng [1 ]
Chen, Hong [2 ]
Zhang, Shu-Hui [1 ]
Liu, Sheng-Yi [2 ]
Wei, Fang [2 ]
Dong, Xu-Yan [2 ]
Cheng, Jie-Ke [1 ]
Huang, Wei-Hua [1 ]
机构
[1] Wuhan Univ, Coll Chem & Mol Sci, Minist Educ, Key Lab Analyt Chem Biol & Med, Wuhan 430072, Peoples R China
[2] Chinese Acad Agr Sci, Oil Crops Res Inst, Minist Agr, Key Lab Oil Crops Biol, Wuhan 430062, Peoples R China
基金
中国国家自然科学基金;
关键词
SCANNING ELECTROCHEMICAL MICROSCOPY; RAPE BRASSICA-NAPUS; HYDROGEN-PEROXIDE; REACTIVE OXYGEN; DISEASE RESISTANCE; SCLEROTINIA-SCLEROTIORUM; VESICULAR EXOCYTOSIS; CARBON NANOTUBES; CELLS; RELEASE;
D O I
10.1021/ac901300b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Oxidative bursts from plants play significant roles in plant disease defense and signal transduction; however, it has not hitherto been investigated on individual living plant cells. In this article, we fabricated a novel sensitive electrochemical sensor based on electrochemical deposition of Pt nanoparticles on the surface of carbon fiber microdisk electrodes via a nanopores containing polymer matrix, Nation. The numerous hydrophilic nanochannels in the Nafion clusters coated on the electrode surface served as the molecular template for the deposition and dispersion of Pt, which resulted in the uniform construction of small Pt nanoparticles. The novel sensor displayed a high sensitivity for detection of H2O2 with a detection limit of 5.0 x 10(-9) M. With the use of this microelectrochemical sensor, the oxidative burst from individual living plant protoplasts have been real-time monitored for the first time. The results showed that oxidative burst from single protoplasts triggered by a pathogen analogue were characterized by quanta release with a large number of "transient oxidative microburst!' events, and protoplasts from the transgenic plants biologically displayed better disease-resistance and showed a distinguished elevation and longer-lasting oxidative burst.
引用
收藏
页码:8453 / 8458
页数:6
相关论文
共 45 条
  • [1] Fabrication of stable bimetallic nanostructures on Nafion membranes for optical applications
    Alvarez-Puebla, Ramon A.
    Nazri, G. -Abbas
    Aroca, Ricardo F.
    [J]. JOURNAL OF MATERIALS CHEMISTRY, 2006, 16 (28) : 2921 - 2924
  • [2] Monitoring in real time with a microelectrode the release of reactive oxygen and nitrogen species by a single macrophage stimulated by its membrane mechanical depolarization
    Amatore, C
    Arbault, S
    Bouton, C
    Coffi, K
    Drapier, JC
    Ghandour, H
    Tong, YH
    [J]. CHEMBIOCHEM, 2006, 7 (04) : 653 - 661
  • [3] Analysis of individual biochemical events based on artificial synapses using ultramicroelectrodes: cellular oxidative burst
    Amatore, C
    Arbault, S
    Bruce, D
    de Oliveira, P
    Erard, M
    Vuillaume, M
    [J]. FARADAY DISCUSSIONS, 2000, 116 : 319 - 333
  • [4] Electrochemical monitoring of single cell secretion:: Vesicular exocytosis and oxidative stress
    Amatore, Christian
    Arbault, Stephane
    Guille, Manon
    Lemaitre, Frederic
    [J]. CHEMICAL REVIEWS, 2008, 108 (07) : 2585 - 2621
  • [5] Real-time amperometric analysis of reactive oxygen and nitrogen species released by single immunostimulated macrophages
    Amatore, Christian
    Arbault, Stephane
    Bouton, Cecile
    Drapier, Jean-Claude
    Ghandour, Hala
    Koh, Alaric C. W.
    [J]. CHEMBIOCHEM, 2008, 9 (09) : 1472 - 1480
  • [6] MONITORING AN OXIDATIVE STRESS MECHANISM AT A SINGLE HUMAN FIBROBLAST
    ARBAULT, S
    PANTANO, P
    JANKOWSKI, JA
    VUILLAUME, M
    AMATORE, C
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (19) : 3382 - 3390
  • [7] Mesoporous platinum films from lyotropic liquid crystalline phases
    Attard, GS
    Bartlett, PN
    Coleman, NRB
    Elliott, JM
    Owen, JR
    Wang, JH
    [J]. SCIENCE, 1997, 278 (5339) : 838 - 840
  • [8] Mechanisms for the generation of reactive oxygen species in plant defence - a broad perspective
    Bolwell, GP
    Wojtaszek, P
    [J]. PHYSIOLOGICAL AND MOLECULAR PLANT PATHOLOGY, 1997, 51 (06) : 347 - 366
  • [9] Efficient electrocatalyst utilization: Electrochemical deposition of Pt nanoparticles using nafion membrane as a template
    Chou, J
    Jayaraman, S
    Ranasinghe, AD
    McFarland, EW
    Buratto, SK
    Metiu, H
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 2006, 110 (14) : 7119 - 7121
  • [10] Patch amperometry: high-resolution measurements of single-vesicle fusion and release
    Dernick, G
    Gong, LW
    Tabares, L
    de Toledo, GA
    Lindau, M
    [J]. NATURE METHODS, 2005, 2 (09) : 699 - 708