Transcatheter Aortic Valve Replacement With Balloon-Expandable Valves Comparison of SAPIEN 3 Ultra Versus SAPIEN 3

被引:56
作者
Rheude, Tobias [1 ]
Pellegrini, Costanza [1 ]
Lutz, Jannik [1 ]
Alvarez-Covarrubias, Hector A. [1 ]
Lahmann, Anna Lena [1 ]
Mayr, N. Patrick [2 ]
Michel, Jonathan [3 ]
Kasel, Markus A. [3 ]
Joner, Michael [1 ,4 ]
Xhepa, Erion [1 ]
机构
[1] Tech Univ Munich, Deutsch Herzzentrum Munchen, Klin Herz & Kreislauferkrankungen, Lazarettstr 36, D-80636 Munich, Germany
[2] Tech Univ Munich, Deutsch Herzzentrum Munchen, Inst Anasthesiol, Munich, Germany
[3] Univ Spital Zurich, Univ Herzzentrum Zurich, Klin Kardiol, Zurich, Switzerland
[4] DZHK German Ctr Cardiovasc Res, Partner Site Munich Heart Alliance, Munich, Germany
关键词
SAPIEN; 3; Ultra; transcatheter aortic valve replacement; transcatheter heart valves; PARAVALVULAR REGURGITATION; IMPLANTATION; IMPACT; OUTCOMES;
D O I
10.1016/j.jcin.2020.07.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The aim of this study was to compare outcomes after transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 Ultra (Ultra) and SAPIEN 3 (S3) transcatheter heart valves (THVs). BACKGROUND The latest generation balloon-expandable Ultra THV incorporates new technical features and might improve outcomes following TAVR. METHODS This registry included all consecutive patients who underwent TAVR with either the Ultra or S3 between January 2014 and January 2020. One-to-one propensity score matching was performed to account for differences in baseline characteristics. In-hospital and 30-day Valve Academic Research Consortium-2-defined outcomes were investigated. RESULTS A total of 310 patients (n = 155 Ultra, n = 155 S3) were included. There were no significant differences in baseline characteristics after propensity score matching. Procedures were significantly more often performed under conscious sedation with Ultra compared with S3 (97.4% vs. 71.6%; p < 0.001). Pre-dilatation was more frequent with S3 compared with Ultra (85.2% vs. 42.6%; p < 0.001). In-hospital outcomes, including device success (91.6% vs. 95.5%; p = 0.165), major vascular complications (12.3% vs. 11.0%; p = 0.723), and new pacemaker implantation (5.8% vs. 4.5%; p = 0.608), were comparable between S3 and Ultra patients, respectively. Post-procedural mean transprosthetic gradients (13.2 +/- 5.7 mm Hg vs. 13.1 +/- 4.7 mm Hg; p = 0.829) and rate of moderate or greater paravalvular leakage (PVL) (1.3% vs. 2.7%; p = 0.414) were comparable, whereas mild PVL was more frequent with S3 compared with Ultra (43.0% vs. 18.7%; p < 0.001). CONCLUSIONS Device success rates were high with both balloon-expandable THVs, with overall low rates of adverse events up to 30 days after TAVR. Despite a lower frequency of pre-dilatation, significant reduction of mild PVL confirms improved annular sealing properties of the novel Ultra THV. (C) 2020 by the American College of Cardiology Foundation.
引用
收藏
页码:2631 / 2638
页数:8
相关论文
共 31 条
[1]   Does mild paravalvular regurgitation post transcatheter aortic valve implantation affect survival? A meta-analysis [J].
Ando, Tomo ;
Briasoulis, Alexandros ;
Telila, Tesfaye ;
Afonso, Luis ;
Grines, Cindy L. ;
Takagi, Hisato .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 91 (01) :135-147
[2]   Balloon-expandable transcatheter aortic valve implantation with or without pre-dilation - results of a meta-analysis of 3 multicenter registries [J].
Ashauer, Jannik Ole ;
Bonaros, Nikolaos ;
Kofler, Markus ;
Schymik, Gerhard ;
Butter, Christian ;
Romano, Mauro ;
Bapat, Vinayak ;
Strauch, Justus ;
Schroefel, Holger ;
Busjahn, Andreas ;
Deutsch, Cornelia ;
Bramlage, Peter ;
Kurucova, Jana ;
Thoenes, Martin ;
Baldus, Stephan ;
Rudolph, Tanja K. .
BMC CARDIOVASCULAR DISORDERS, 2019, 19 (1)
[3]   Procedural Results and Clinical Outcomes of Transcatheter Aortic Valve Implantation in Switzerland An Observational Cohort Study of Sapien 3 Versus Sapien XT Transcatheter Heart Valves [J].
Binder, Ronald K. ;
Stortecky, Stefan ;
Heg, Dik ;
Tueller, David ;
Jeger, Raban ;
Toggweiler, Stefan ;
Pedrazzini, Giovanni ;
Amann, Franz W. ;
Ferrari, Enrico ;
Noble, Stephane ;
Nietlispach, Fabian ;
Maisano, Francesco ;
Raber, Lorenz ;
Roffi, Marco ;
Grunenfelder, Jurg ;
Juni, Peter ;
Huber, Christoph ;
Windecker, Stephan ;
Wenaweser, Peter .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (10)
[4]   Transcatheter Aortic Valve Replacement With the SAPIEN 3 A New Balloon-Expandable Transcatheter Heart Valve [J].
Binder, Ronald K. ;
Rodes-Cabau, Josep ;
Wood, David A. ;
Mok, Michael ;
Leipsic, Jonathon ;
De Larochelliere, Robert ;
Toggweiler, Stefan ;
Dumont, Eric ;
Freeman, Melanie ;
Willson, Alexander B. ;
Webb, John G. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (03) :293-300
[5]   Changes in the Pacemaker Rate After Transition From Edwards SAPIEN XT to SAPIEN 3 Transcatheter Aortic Valve Implantation The Critical Role of Valve Implantation Height [J].
De Torres-Alba, Fernando ;
Kaleschke, Gerrit ;
Diller, Gerhard Paul ;
Vormbrock, Julia ;
Orwat, Stefan ;
Radke, Robert ;
Reinke, Florian ;
Fischer, Dieter ;
Reinecke, Holger ;
Baumgartner, Helmut .
JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (08) :805-813
[6]   Annual number of candidates for transcatheter aortic valve implantation per country: current estimates and future projections [J].
Durko, Andras P. ;
Osnabrugge, Ruben L. ;
Van Mieghem, Nicolas M. ;
Milojevic, Milan ;
Mylotte, Darren ;
Nkomo, Vuyisile T. ;
Kappetein, A. Pieter .
EUROPEAN HEART JOURNAL, 2018, 39 (28) :2635-2642
[7]   The Minimalist Approach for Transcatheter Aortic Valve Replacement in High-Risk Patients [J].
Dvir, Danny ;
Jhaveri, Rajiv ;
Pichard, Augusto D. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (05) :468-469
[8]   2017 ESC/EACTS Guidelines for the management of valvular heart disease [J].
Falk, Volkmar ;
Baumgartner, Helmut ;
Bax, Jeroen J. ;
De Bonis, Michele ;
Hamm, Christian ;
Holm, Per Johan ;
Iung, Bernard ;
Lancellotti, Patrizio ;
Lansac, Emmanuel ;
Rodriguez Munoz, Daniel ;
Rosenhek, Raphael ;
Sjogren, Johan ;
Tornos Mas, Pilar ;
Vahanian, Alec ;
Walther, Thomas ;
Wendler, Olaf ;
Windecker, Stephan ;
Luis Zamorano, Jose .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 52 (04) :616-664
[9]  
Frangieh AH, 2017, STRUCT HEART, V1, P169, DOI 10.1080/24748706.2017.1358832
[10]   Transvascular transcatheter aortic valve implantation in 2017 [J].
Gaede, Luise ;
Blumenstein, Johannes ;
Liebetrau, Christoph ;
Doerr, Oliver ;
Kim, Won-Keun ;
Nef, Holger ;
Husser, Oliver ;
Guelker, Jan ;
Elsaesser, Albrecht ;
Hamm, Christian W. ;
Achenbach, Stephan ;
Moellmann, Helge .
CLINICAL RESEARCH IN CARDIOLOGY, 2020, 109 (03) :303-314