Reliability and loading-following studies of a heat pipe cooled, AMTEC conversion space reactor power system

被引:18
作者
Ge Li [1 ]
Li Huaqia [1 ,2 ]
Shan Jianqiang [1 ]
机构
[1] Xi An Jiao Tong Univ, Xian 710049, Shaanxi, Peoples R China
[2] Northwest Inst Nucl Technol, Xian 710024, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
SRPS; AMTEC; Load following; Radiator; Safety and reliability; MODEL;
D O I
10.1016/j.anucene.2019.02.029
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
During the progress and development of the space technology, the space reactor power system (SRPS) is one of the best options for providing high power density, long-term life, light weight, and high reliability space power for civil or military space missions. The heat pipe cooled SRPS (HPS) equipped with the static conversion technology Alkali Metal Thermal-to-Electric Conversion units (AMTEC) has good inherent dynamic characteristic for frequent change load following of the space mission power, with high safety and reliability. This paper analyzed the system safety and reliability of an AMTEC conversion HPS, the load following characteristics of the AMTEC conversion and the HPS's performance in response to partial surface area loss of potassium heat pipe radiator. The results show the following. (1) As the external load resistance increases, the AMTEC thermoelectric conversion efficiency and electric power output both increase to the maximum, and then decrease. The maximum thermoelectric conversion efficiency and electric power output correspond to different critical external load values. The load following capacity of the AMTEC HPS exists only when the external load demands exceed a critical value. (2) When the potassium heat pipe radiator's surface area is partially lost because of the impact of a meteorite, the reactor thermal power, the AMTEC conversion efficiency and the electric power output also decrease, except the radiator temperature due to the radiator area loss. The waste heat rejection, the conversion efficiency and electric power output of the system decrease proportionally to the radiator's surface area loss. To ensure the safety and reliability of the SRPS, the reactor thermal power will run down after the loss of the radiator's surface area. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:82 / 92
页数:11
相关论文
共 21 条
[1]  
El-Genk M. S., 1992, 31992 UNMISNPS
[2]   SAIRS - Scalable Amtec Integrated Reactor Space Power System [J].
El-Genk, MS ;
Tournier, JMP .
PROGRESS IN NUCLEAR ENERGY, 2004, 45 (01) :25-69
[3]   AMTEC/TE static converters for high energy utilization, small nuclear power plants [J].
El-Genk, MS ;
Tournier, JMP .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (04) :511-535
[4]   LOAD-FOLLOWING AND RELIABILITY STUDIES OF AN INTEGRATED SP-100 SYSTEM [J].
ELGENK, MS ;
SEO, JT ;
BUKSA, JJ .
JOURNAL OF PROPULSION AND POWER, 1988, 4 (02) :152-156
[5]  
Gaeta MJ., 1988, TRANSIENT THERMAL AN
[6]   Brayton rotating units for space reactor power systems [J].
Gallo, Bruno M. ;
El-Genk, Mohamed S. .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (09) :2210-2232
[7]  
Gunther N.G., 1990, Report No. SPI-52-1
[8]  
HAWLEY JP, 1967, NAASR11361
[9]  
Lamp T., 1991, ADV THERMIONICS INIT, P218
[10]  
[李华琪 Li Huaqi], 2015, [原子能科学技术, Atomic Energy Science and Technology], V49, P89