Specificity of treadmill and cycle ergometer tests in triathletes, runners and cyclists

被引:83
作者
Basset, FA [1 ]
Boulay, MR [1 ]
机构
[1] Univ Laval, Fac Med, Div Kinesiol, Phys Act Sci Lab, Ste Foy, PQ G1K 7P4, Canada
关键词
performance test; specificity; V (over dot)O-2max; monitoring of training;
D O I
10.1007/s004210050033
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The objective of this study was to evaluate the viability of using a single test in which cardiorespiratory variables are measured, to establish training guidelines in running and/or cycling training activities. Six triathletes (two females and four males), six runners (two females and four males) and six males cyclists, all with 5.5 years of serious training and still involved in racing, were tested on a treadmill and cycle ergometer. Cardiorespiratory variables [e.g., heart rate (HR), minute ventilation, carbon dioxide output ((V) over dot CO2)] were calculated relative to fixed percentages of maximal oxygen uptake ((V) over dot O-2max, from 50 to 100%). The entire group of subjects had significantly (P < 0.05) higher values of (V) over dot O-2max on the treadmill compared with the cycle ergometer [mean (SEM) 4.7 (0.8) and 4.4 (0.9) l . min(-1), respectively], and differences between tests averaged 10.5% for runners, 6.1% for triathletes and 2.8% for cyclists. A three-way analysis of variance using a 3 x 2 x 6 design (groups x tests x intensities) demonstrated that all factors yielded highly significant F-ratios (P < 0.05) for all variables between tests, even though differences in HR were only 4 beats . min(-1). When HR was plotted against a fixed percentage of (V) over dot O-2max, a high correlation was found between tests. These results demonstrate that for triathletes, cyclists and runners, the relationship between HR and percentage of (V) over dot O-2max, obtained in either a treadmill or a cycle ergometer test, may be used independently of absolute (V) over dot O-2max to obtain reference HR values that can be used to monitor their running and/or cycling training bouts.
引用
收藏
页码:214 / 221
页数:8
相关论文
共 37 条
  • [1] THE RELATION BETWEEN POWER OUTPUT, OXYGEN-UPTAKE AND HEART-RATE IN MALE-ATHLETES
    ARTS, FJP
    KUIPERS, H
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1994, 15 (05) : 228 - 231
  • [2] BARBEAU P, 1993, MED SCI SPORT EXER, V25, P1062
  • [3] SPECIFICITY OF MAXIMAL AEROBIC POWER
    BOUCHARD, C
    GODBOUT, P
    MONDOR, JC
    LEBLANC, C
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1979, 40 (02): : 85 - 93
  • [4] PHYSIOLOGICAL MONITORING OF ELITE CYCLISTS - PRACTICAL METHODS
    BOULAY, MR
    [J]. SPORTS MEDICINE, 1995, 20 (01) : 1 - 11
  • [5] Monitoring high-intensity endurance exercise with heart rate and thresholds
    Boulay, MR
    Simoneau, JA
    Lortie, G
    Bouchard, C
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1997, 29 (01) : 125 - 132
  • [6] LINEAR INCREASE IN OPTIMAL PEDAL RATE WITH INCREASED POWER OUTPUT IN CYCLE ERGOMETRY
    COAST, JR
    WELCH, HG
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1985, 53 (04): : 339 - 342
  • [7] DETERMINANTS OF SUCCESS DURING TRIATHLON COMPETITION
    DENGEL, DR
    FLYNN, MG
    COSTILL, DL
    KIRWAN, JP
    [J]. RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 1989, 60 (03) : 234 - 238
  • [8] Cross training: indices of training stress and performance
    Flynn, MG
    Carroll, KK
    Hall, HL
    Bushman, BA
    Brolinson, PG
    Weideman, CA
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1998, 30 (02) : 294 - 300
  • [9] FOSTER C, 1978, MED SCI SPORTS, V11, P338
  • [10] The use of heart rate to monitor the intensity of endurance training
    Gilman, MB
    [J]. SPORTS MEDICINE, 1996, 21 (02) : 73 - 79