Effect of myocardial contractility on hemodynamic end points under concomitant microvascular disease in a porcine model

被引:13
作者
Peelukhana, Srikara Viswanath [1 ,2 ]
Kolli, Kranthi K. [1 ,2 ]
Leesar, Massoud A. [2 ,3 ]
Effat, Mohamed A. [2 ,3 ]
Helmy, Tarek A. [2 ,3 ]
Arif, Imran [2 ,3 ]
Schneeberger, Eric W. [4 ]
Succop, Paul [5 ]
Banerjee, Rupak K. [1 ,2 ]
机构
[1] Univ Cincinnati, Dept Mech Engn, Sch Dynam Syst, Cincinnati, OH 45220 USA
[2] Vet Affairs Med Ctr, Cincinnati, OH 45220 USA
[3] Univ Cincinnati, Div Cardiovasc Dis, Cincinnati, OH 45221 USA
[4] Deaconess Hosp, Cincinnati, OH 45221 USA
[5] Univ Cincinnati, Dept Environm Hlth, Cincinnati, OH 45221 USA
关键词
Coronary artery disease; Myocardial contractility; Diagnostic parameter; Microcirculation; Microsphere; Hemodynamics; Catheterization; Statistics; FRACTIONAL FLOW RESERVE; CORONARY-ARTERY-DISEASE; PRESSURE-DROP COEFFICIENT; LEFT-VENTRICULAR FUNCTION; DP-DT MAX; INTRAVASCULAR ULTRASOUND; MULTIVESSEL EVALUATION; STENOSIS SEVERITY; HEART-RATE; IN-VITRO;
D O I
10.1007/s00380-013-0355-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In this study, coronary diagnostic parameters, pressure drop coefficient (CDP: ratio of trans-stenotic pressure drop to distal dynamic pressure), and lesion flow coefficient (LFC: ratio of % area stenosis (%AS) to the CDP at throat region), were evaluated to distinguish levels of %AS under varying contractility conditions, in the presence of microvascular disease (MVD). In 10 pigs, %AS and MVD were created using angioplasty balloons and 90-mu m microspheres, respectively. Simultaneous measurements of pressure drop, left ventricular pressure (p), and velocity were obtained. Contractility was calculated as (dp/dt)(max), categorized into low contractility < 900 mmHg/s and high contractility > 900 mmHg/s, and in each group, compared between %AS < 50 and > 50 using analysis of variance. In the presence of MVD, between the %AS < 50 and > 50 groups, values of CDP (71 +/- 1.4 and 121 +/- 1.3) and LFC (0.10 +/- 0.04 and 0.19 +/- 0.04) were significantly different (P < 0.05), under low-contractility conditions. A similar %AS trend was observed under high-contractility conditions (CDP: 18 +/- 1.4 and 91 +/- 1.4; LFC: 0.08 +/- 0.04 and 0.25 +/- 0.04). Under MVD conditions, similar to fractional flow reserve, CDP and LFC were not influenced by contractility.
引用
收藏
页码:97 / 109
页数:13
相关论文
共 71 条
[1]   Epicardial stenosis severity does not affect minimal microcirculatory resistance [J].
Aarnoudse, W ;
Fearon, WF ;
Manoharan, G ;
Geven, M ;
van de Vosse, F ;
Rutten, M ;
De Bruyne, B ;
Pijls, NHJ .
CIRCULATION, 2004, 110 (15) :2137-2142
[2]   Myocardial resistance assessed by guidewire-based pressure-temperature measurement: In vitro validation [J].
Aarnoudse, W ;
van den Berg, P ;
van de Vosse, F ;
Geven, M ;
Rutten, M ;
van Turnhout, M ;
Fearon, W ;
De Bruyne, B ;
Pijls, N .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 62 (01) :56-63
[3]   Time to dP/dt(max), a useful index for evaluation of contractility in the catheterization laboratory [J].
Adler, D ;
Monrad, ES ;
Hess, OM ;
Krayenbuehl, HP ;
Sonnenblick, EH .
CLINICAL CARDIOLOGY, 1996, 19 (05) :397-403
[4]   Validation of Minimal Luminal Area Measured by Intravascular Ultrasound for Assessment of Functionally Significant Coronary Stenosis Comparison With Myocardial Perfusion Imaging [J].
Ahn, Jung-Min ;
Kang, Soo-Jin ;
Mintz, Gary S. ;
Oh, Jun-Hyok ;
Kim, Won-Jang ;
Lee, Jong-Young ;
Park, Duk-Woo ;
Lee, Seung-Whan ;
Kim, Young-Hak ;
Lee, Cheol Whan ;
Park, Seong-Wook ;
Moon, Dae Hyuk ;
Park, Seung-Jung .
JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (06) :665-671
[5]  
[Anonymous], 2011, INTRO FLUID MECH
[6]  
Ashtekar K., 2007, Journal of Medical Devices, V1, P185, DOI DOI 10.1115/1.2776336
[7]   Catheter obstruction effect on pulsatile flow rate-pressure drop during coronary angioplasty [J].
Banerjee, RK ;
Back, LH ;
Back, MR ;
Cho, YI .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (03) :281-289
[8]   Characterizing momentum change and viscous loss of a hemodynamic endpoint in assessment of coronary lesions [J].
Banerjee, Rupak K. ;
Roy, Abhijit Sinha ;
Back, Lloyd H. ;
Back, Martin R. ;
Khoury, Saeb F. ;
Millard, Ronald W. .
JOURNAL OF BIOMECHANICS, 2007, 40 (03) :652-662
[9]  
Banerjee RK, 2009, J INVASIVE CARDIOL, V21, P511
[10]   Hemodynamic diagnostics of epicardial coronary stenoses:: in-vitro experimental and computational study [J].
Banerjee, Rupak K. ;
Ashtekar, Koustubh D. ;
Helmy, Tarek A. ;
Effat, Mohamed A. ;
Back, Lloyd H. ;
Khoury, Saeb F. .
BIOMEDICAL ENGINEERING ONLINE, 2008, 7 (1)