Assembly of electroactive layer-by-layer films of myoglobin and ionomer poly(ester sulfonic acid)

被引:26
作者
Li, Z [1 ]
Hu, NF [1 ]
机构
[1] Beijing Normal Univ, Dept Chem, Beijing 100875, Peoples R China
基金
中国国家自然科学基金;
关键词
myoglobin; poly(ester sulfonic acid); Eastman AQ; layer-by-layer assembly films; direct electrochemistry; electrocatalysis;
D O I
10.1006/jcis.2002.8574
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Layer-by-layer films were assembled on solid substrates by alternate adsorption of negatively charged ionomer poly(ester sulfonic acid) or Eastman AQ55 from its aqueous dispersion and positively charged myoglobin (Mb) from its solution at pH 4.5. The film assembly process was monitored by cyclic voltammetry (CV), UV-vis spectroscopy, and quartz crystal microbalance (QCM). {AQ/Mb}(n) films grown on pyrolytic graphite (PG) electrodes showed a pair of well-defined and nearly reversible CV peaks at about -0.20 V vs Ag/AgCl in pH 5.5 buffers, characteristic of the Mb heme Fe(III)/Fe(II) redox couple. Although the amount of Mb adsorbed in each bilayer was essentially the same, the fraction of electroactive Mb decreased dramatically with an increase of bilayer number (n). Soret absorption bands of {AQ/Mb}(n) films on glass slides suggest that Mb in the films retains its native state in the medium pH range. Trichloroacetic acid, oxygen, and hydrogen peroxide were electrochemically catalyzed by {AQ/Mb}(6) films with significant lowering of reduction overpotential. (C) 2002 Elsevier Science (USA).
引用
收藏
页码:257 / 265
页数:9
相关论文
共 50 条
[41]   Simultaneous determination of dopamine and uric acid using layer-by-layer graphene and chitosan assembled multilayer films [J].
Weng, Xuexiang ;
Cao, Qingxue ;
Liang, Lixin ;
Chen, Jianrong ;
You, Chunping ;
Ruan, Yongmin ;
Lin, Hongjun ;
Wu, Lanju .
TALANTA, 2013, 117 :359-365
[42]   Phytic Acid-Based Layer-by-Layer Assembly for Fabrication of Mesoporous Gold Film and Its Biosensor Application [J].
Wang, Yao ;
Ma, Xiaoling ;
Wen, Ying ;
Zheng, Yaqing ;
Duan, Guoping ;
Zhang, Zongrang ;
Yangz, Haifeng .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2010, 157 (01) :K5-K9
[43]   Layer-by-layer assembly of Ru3+ and Si8O208- into electrochemically active silicate films [J].
Rassaei, Liza ;
Sillanpaa, Mika ;
Milsom, Elizabeth V. ;
Zhang, Xiaohang ;
Marken, Frank .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2008, 12 (06) :747-755
[44]   Direct electrochemistry of myoglobin in a layer-by-layer film on an ionic liquid modified electrode containing CeO2 nanoparticles and hyaluronic acid [J].
Ruifang Gao ;
Jianbin Zheng ;
Xiaohui Zheng .
Microchimica Acta, 2011, 174 :273-280
[45]   Electrocatalytic properties of heme proteins in layer-by-layer films assembled with SiO2 nanoparticles [J].
He, PL ;
Hu, NF .
ELECTROANALYSIS, 2004, 16 (13-14) :1122-1131
[46]   Direct Electrochemistry of Hemoglobin in Layer-by-Layer Films Assembled with DNA and Room Temperature Ionic Liquid [J].
Gao, Ruifang ;
Zheng, Jianbin ;
Qiao, Lifang .
ELECTROANALYSIS, 2010, 22 (10) :1084-1089
[47]   The layer-by-layer assembly of polyelectrolyte functionalized graphene sheets: A potential tool for biosensing [J].
Ma, Jianbo ;
Cai, Peng ;
Qi, Wei ;
Kong, Desheng ;
Wang, Hua .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2013, 426 :6-11
[48]   Polyethyleneimine-functionalized graphene and its layer-by-layer assembly with Prussian blue [J].
Shan, Changsheng ;
Wang, Lingnan ;
Han, Dongxue ;
Li, Fenghua ;
Zhang, Qixian ;
Zhang, Xindong ;
Niu, Li .
THIN SOLID FILMS, 2013, 534 :572-576
[49]   Amperometric Cholesterol Biosensor Using Layer-by-Layer Adsorption Technique on Polyaniline-coated Polyester Films [J].
Shin, Min Jae ;
Kim, Jin Gon ;
Shin, Jae Sup .
INTERNATIONAL JOURNAL OF POLYMERIC MATERIALS AND POLYMERIC BIOMATERIALS, 2013, 62 (03) :140-144
[50]   Direct electrochemistry of hemoglobin in layer-by-layer {PDDA/Hb}n films assembled on pyrolytic graphite electrodes [J].
He, PL ;
Hu, NF .
CHINESE CHEMICAL LETTERS, 2001, 12 (07) :629-630