Femoroplasty-augmentation of mechanical properties in the osteoporotic proximal femur: a biomechanical investigation of PMMA reinforcement in cadaver bones

被引:112
作者
Heini, PF [1 ]
Franz, T
Fankhauser, C
Gasser, B
Ganz, R
机构
[1] Univ Bern, Inselspital, Dept Orthoped Surg, CH-3010 Bern, Switzerland
[2] R Mathys Fdn, CH-2544 Bettlach, Switzerland
关键词
femur; hip; fracture; osteoporosis; PMMA; femoroplasty; bone cement; reinforcement;
D O I
10.1016/j.clinbiomech.2004.01.014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To determine the feasibility of polymethyl-methacrylate injection into the osteoporotic proximal femur and its effect on the mechanical properties. Design. In vitro pairwise comparison of non reinforced and reinforced bones in a load to failure loading mode. Background. Hip fractures represent an important public healthcare problem. Continued growth in the elderly population will raise the incidence of hip fractures and their associated costs dramatically in the near future. Methods. Twenty pairs of osteoporotic femurs were mechanically tested either in a single-limb stance configuration or simulating a fall on the greater trochanter. From each pair, one femur was augmented with bone cement, with the contralateral femur serving as a control. The surface temperature at the femoral neck was recorded until twenty minutes after injection. The fracture load and the energy absorption were calculated. The Wilcoxon signed rank test was used to test for differences in fracture load and energy absorption between the reinforced femurs and the native controls. Results. Volumes of 28-41 ml of cement (mean, 36 ml) could be injected. The increase of surface temperature at the femoral neck ranged from Delta18.4 to Delta29.8 degreesC. For the single limb stance configurations, the peak fracture load was increased by 21%, (P < 0.002) and for the simulated fall on the hip by 82%, (P < 0.002). The corresponding values for energy absorption were +48%; and +188% (P < 0.002) respectively. Conclusions. The feasibility and mechanical effectiveness of the in vitro procedure could be demonstrated. The heat generation due to polymethyl-methacrylate polymerisation is high.
引用
收藏
页码:506 / 512
页数:7
相关论文
共 40 条
  • [11] ELFFORS L, 1998, AGING, V3, P191
  • [12] Ettinger B., 1998, J Managed Care Pharm, V4, P488, DOI [10.18553/jmcp.1998.4.5.488, DOI 10.18553/JMCP.1998.4.5.488]
  • [13] FAULKNER KG, 1994, J BONE MINER RES, V9, P1065
  • [14] Anatomy of the medial femoral circumflex artery and its surgical implications
    Gautier, E
    Ganz, K
    Krügel, N
    Gill, T
    Ganz, R
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (05): : 679 - 683
  • [15] Goodman SB, 1998, CLIN ORTHOP RELAT R, P42
  • [16] Percutaneous transpedicular vertebroplasty with PMMA:: operative technique and early results -: A prospective study for the treatment of osteoporotic compression fractures
    Heini, PF
    Wälchli, B
    Berlemann, U
    [J]. EUROPEAN SPINE JOURNAL, 2000, 9 (05) : 445 - 450
  • [17] Augmentation of mechanical properties in osteoporotic vertebral bones - a biomechanical investigation of vertebroplasty efficacy with different bone cements
    Heini, PF
    Berlemann, U
    Kaufmann, M
    Lippuner, K
    Fankhauser, C
    van Landuyt, P
    [J]. EUROPEAN SPINE JOURNAL, 2001, 10 (02) : 164 - 171
  • [18] The prevalence and impact of self-reported hip fracture in elderly community-dwelling women: The women's health and aging study
    Hochberg, MC
    Williamson, J
    Skinner, EA
    Guralnik, J
    Kasper, JD
    Fried, LP
    [J]. OSTEOPOROSIS INTERNATIONAL, 1998, 8 (04) : 385 - 389
  • [19] Johnell O, 1997, Am J Med, V103, p20S, DOI 10.1016/S0002-9343(97)90023-1
  • [20] Johnell O., 1997, AM J MED, V103, p25S