A deformable image registration method to handle distended rectums in prostate cancer radiotherapy

被引:60
作者
Gao, Song [1 ]
Zhang, Lifei [1 ]
Wang, He [1 ]
de Crevoisier, Renaud [1 ]
Kuban, Deborah D. [1 ]
Mohan, Radhe [1 ]
Dong, Lei [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Unit 94, Houston, TX 77030 USA
关键词
deformable image registration; image intensity modification; image-guided radiotherapy; autosegmentation; prostate cancers;
D O I
10.1118/1.2222077
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In image-guided adaptive radiotherapy, it is important to have the capability to automatically and accurately delineate the rectal wall, which is a major dose-limiting organ in prostate cancer radiotherapy. As image registration is a process to find the spatial correspondence between two images, a major challenge in intensity-based deformable image registration is to deal with the situation where no correspondence exists for some objects between the two images to be registered. One example is the variation of rectal contents due to the presence and absence of bowel gas. The intensity-based deformable image registration methods alone cannot create the correct spatial transformation if there is no correspondence between the source and target images. In this study we implemented an automatic image intensity modification procedure to create artificial gas pockets in the planning computed tomography (CT) images. A diffusion-based deformable image registration algorithm was developed to use an adaptive smoothing algorithm to better handle large organ deformations. The process was tested in 15 prostate cancer cases and 30 daily CT images containing the largest distended rectums. The manually delineated rectums agreed well with the autodelineated rectums when using the image-intensity modification procedure. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:3304 / 3312
页数:9
相关论文
共 32 条
[1]   Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system [J].
Barker, JL ;
Garden, AS ;
Ang, KK ;
O'Daniel, JC ;
Wang, H ;
Court, LE ;
Morrison, WH ;
Rosenthal, DI ;
Chao, KSC ;
Tucker, SL ;
Mohan, R ;
Dong, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04) :960-970
[3]  
BRANDT A, 1977, MATH COMPUT, V31, P333, DOI 10.1090/S0025-5718-1977-0431719-X
[4]   LINEAR-TIME EUCLIDEAN DISTANCE TRANSFORM ALGORITHMS [J].
BREU, H ;
GIL, J ;
KIRKPATRICK, D ;
WERMAN, M .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1995, 17 (05) :529-533
[5]   Accuracy of finite element model-based multi-organ deformable image registration [J].
Brock, KK ;
Sharpe, MB ;
Dawson, LA ;
Kim, SM ;
Jaffray, DA .
MEDICAL PHYSICS, 2005, 32 (06) :1647-1659
[6]   Variational optical flow computation in real time [J].
Bruhn, A ;
Weickert, J ;
Feddern, C ;
Kohlberger, T ;
Schnörr, C .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2005, 14 (05) :608-615
[7]   An automatic CT-guided adaptive radiation therapy technique by online modification of multileaf collimator leaf positions for prostate cancer [J].
Court, LE ;
Dong, L ;
Lee, AK ;
Cheung, R ;
Bonnen, MD ;
O'Daniel, J ;
Wang, H ;
Mohan, R ;
Kuban, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (01) :154-163
[8]   Evaluation of a contour-alignment technique for CT-guided prostate radiotherapy: An intra- and interobserver study [J].
Court, LE ;
Dong, L ;
Taylor, N ;
Ballo, M ;
Kitamura, K ;
Lee, AK ;
O'Daniel, J ;
White, RA ;
Cheung, R ;
Kuban, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (02) :412-418
[9]   Automatic registration of the prostate for computed-tomography-guided radiotherapy [J].
Court, LE ;
Dong, L .
MEDICAL PHYSICS, 2003, 30 (10) :2750-2757
[10]   Non-rigid image registration: theory and practice [J].
Crum, WR ;
Hartkens, T ;
Hill, DLG .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 :S140-S153