Experimental investigation on R134a vapour ejector refrigeration system

被引:134
作者
Selvaraju, A. [1 ]
Mani, A. [1 ]
机构
[1] Indian Inst Technol, Dept Mech Engn, Refrigerat & Airconditioning Lab, Madras 600036, Tamil Nadu, India
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2006年 / 29卷 / 07期
关键词
refrigeration system; ejector system; R134a; experiment; performance;
D O I
10.1016/j.ijrefrig.2006.01.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
The experimental investigation of the performance of a vapour ejector refrigeration system is described. The system uses R134a as working fluid and has a rated cooling capacity of 0.5 kW. The influence of generator, evaporator and condenser temperatures on the system performance is studied. This kind of system can be operated with low grade thermal energy such as solar energy, waste heat, etc. The operating conditions are chosen accordingly as, generator temperature between 338 K and 363 K, condenser temperature between 299 K and 310.5 K, and evaporator temperature between 275 K and 285.5 K. Six configurations of ejectors of different geometrical dimensions are selected for the parametric study. The performance of the refrigeration system at different operating temperatures is presented. (c) 2006 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:1160 / 1166
页数:7
相关论文
共 50 条
  • [21] EXPERIMENTAL INVESTIGATION OF R600a/TIO2 AS A DROP-IN REPLACEMENT FOR R134a IN A HOUSEHOLD REFRIGERATION SYSTEM
    Babarinde, T. O.
    Akinlabi, S. A.
    Madyira, D. M.
    4TH THERMAL AND FLUIDS ENGINEERING CONFERENCE, ASTFE 2019, 2019,
  • [22] Experimental investigation of the influence of thermoelectric subcooler on the performance of R134a refrigeration systems
    Wantha, Channarong
    APPLIED THERMAL ENGINEERING, 2020, 180
  • [23] Usage of R513A as an alternative to R134a in a refrigeration system: An experimental investigation based on the Kigali amendment
    Dağıdır K.
    Bilen K.
    International Journal of Thermofluids, 2024, 21
  • [24] A numerical investigation of the compressible flow in the ejector of a vapour ejector refrigeration system
    Megalingam, A.
    Babu, V.
    PROGRESS IN COMPUTATIONAL FLUID DYNAMICS, 2020, 20 (01): : 29 - 39
  • [25] Analysis of COP Using Blended R134a and R600a in Refrigeration System as a Replacement to R134a
    Panda N.K.
    Mishra S.K.
    Samal D.K.
    Padhi B.N.
    Journal of The Institution of Engineers (India): Series C, 2024, 105 (03) : 427 - 435
  • [26] Energy and exergy analysis of R1234yf using instead of R134a in a vapour compression refrigeration system: an experimental study
    Bilen, Kemal
    Dagidir, Kayhan
    Arcaklioglu, Erol
    Cansevdi, Bekir
    INTERNATIONAL JOURNAL OF EXERGY, 2023, 42 (03) : 315 - 336
  • [27] Experimental Analysis of a Hybrid Ejector-based Air-conditioning System Using R134a
    Hao, Wang
    Cai, Wenjian
    Wang, Xinli
    2014 7TH INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION FOR SUSTAINABILITY (ICIAFS), 2014,
  • [28] Experimental evaluation of a R134a/CO2 cascade refrigeration plant
    Sanz-Kock, Carlos
    Llopis, Rodrigo
    Sanchez, Daniel
    Cabello, Ramon
    Torrella, Enrique
    APPLIED THERMAL ENGINEERING, 2014, 73 (01) : 41 - 50
  • [29] Experimental exergy analysis of R513A to replace R134a in a small capacity refrigeration system
    Mota-Babiloni, Adrian
    Belman-Flores, J. M.
    Makhnatch, Pavel
    Navarro-Esbri, Joaquin
    Barroso-Maldonado, J. M.
    ENERGY, 2018, 162 : 99 - 110
  • [30] Experimental Investigation of the Ejector Refrigeration Cycle for Cascade System Application
    Hao, Xinyue
    Gao, Neng
    Chen, Guangming
    Volovyk, Oleksii
    Wang, Xuehui
    Xuan, Yongmei
    JOURNAL OF THERMAL SCIENCE, 2022, 31 (05) : 1476 - 1486