Ultrasound Contrast Imaging Based on a Novel Algorithm Combined Pulse Inversion with Wavelet Transform

被引:0
作者
Zhao, Xiaoyan [1 ]
Wan, Mingxi [1 ]
Zhong, Hui [1 ]
Shen, Liang [1 ]
机构
[1] Xi An Jiao Tong Univ, Key Lab Biomed Informat Engn, Minist Educ, Dept Biomed Engn,Sch Life Sci & Technol, Xian 710049, Peoples R China
来源
2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX | 2008年
关键词
ultrasound contrast agent; pulse inversion; wavelet transform; Bubble wavelet;
D O I
10.1109/ULTSYM.2008.0407
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this paper, a novel ultrasound contrast imaging method which combines the pulse-inversion technique with wavelet transform is proposed in order to enhance the contrast between bubbles and surrounding tissues. Wavelet transform is utilized to analyze the correlation between mother wavelet and received echoes from a pair of inverted transmit pulses respectively. In order to obtain better correlation, a new mother wavelet named "Bubble wavelet" is constructed according to the modified Herring equation. Radio frequency (RF) data were acquired from a modified digital diagnostic ultrasound system. Experiments were performed on an ultrasonic flow phantom and results showed that the contrast-to-tissue ratio (CTR) was improved by 6.4-16.0 dB depending on types of mother wavelet, scales and depths, compared to that obtained using pulse-inversion-based second-harmonic imaging. Experiments in vivo were also conducted out using kidneys of rabbits and results showed that signals of surrounding tissues can be well suppressed compared to that of bubbles. By using Bubble wavelet, the CTR is improved by up to 9.6 dB relative to Morlet wavelet and Mexican Hat wavelet under the same conditions in experiments. Further improvements might be achieved with optimized bubble wavelet which can describe the scattering echoes of the bubbles more accurately.
引用
收藏
页码:1667 / 1670
页数:4
相关论文
共 5 条
[1]  
[Anonymous], 1993, Ten Lectures of Wavelets
[2]  
Morgan KE, 2000, IEEE T ULTRASON FERR, V47, P1494, DOI 10.1109/58.883539
[3]   Pulse inversion Doppler: A new method for detecting nonlinear echoes from microbubble contrast agents [J].
Simpson, DH ;
Chin, CT ;
Burns, PN .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (02) :372-382
[4]  
van der Meer SM, 2004, ULTRASON, P343
[5]   An algorithm for the diagnosis of focal liver masses using microbubble contrast-enhanced pulse-inversion sonography [J].
Wilson, SR ;
Burns, PN .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (05) :1401-1412