A label-free electrochemical immunosensor based on Au@Pd/Ag yolk-bimetallic shell nanoparticles and amination graphene for detection of nuclear matrix protein 22

被引:69
作者
Li, Na [1 ]
Wang, Yulan [1 ]
Li, Yueyun [2 ]
Cao, Wei [1 ]
Ma, Hongmin [1 ]
Wu, Dan [1 ]
Du, Bin [1 ]
Wei, Qin [1 ]
机构
[1] Univ Jinan, Sch Chem & Chem Engn, Key Lab Chem Sensing & Anal Univ Shandong, Jinan 250022, Peoples R China
[2] Shandong Univ Technol, Sch Chem Engn, Zibo 255049, Peoples R China
基金
中国国家自然科学基金;
关键词
Label-free immunosensor; Amination graphene; Yolk-shell nanoparticles; Nuclear matrix protein 22; HUMAN BLADDER-CANCER; IMPEDIMETRIC IMMUNOSENSOR; GOLD NANOPARTICLES; DIAGNOSIS; NMP22; CORE; IMMUNOASSAY; ELECTRODE; NANOSTRUCTURES; MICROSPHERES;
D O I
10.1016/j.snb.2014.05.077
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive label-free electrochemical immunosensor was developed based on Au@Pd/Ag yolk-bimetallic shell nanoparticles (Au@Pd/Ag NPs) and amination graphene (NH2-GS) for the detection of nuclear matrix protein 22 (NMP22). Au@Pd/Ag NPs were loaded on the surface of NH2-GS (NH2-GS/Au@Pd/Ag) by covalent binding between noble metal NPs and amino groups. A glassy carbon electrode (GCE, 4 mm in diameter) was used as the working electrode for the assembly of NPs and NH2-GS. Due to the large specific surface area and excellent electrical conductivity of NH2-GS/Au@Pd/Ag, the electroactivity of K-3[Fe(CN)(6)] as electron transfer mediator was promoted and the amount of NMP22 antibody immobilized was enhanced significantly. Under optimum conditions, the immunosensor exhibited high selectivity and a wide linear range from 0.01 to 18 ng/mL with a detection limit of 3.3 pg/mL. For real sample analysis, the recovery of standard addition was 97.4-99.3% and the relative standard deviation (RSD) was 4.83-7.21%, which indicated that the proposed method exhibited great potential as a reliable technique for the determination of NMP22 for clinical research and diagnostic applications. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:67 / 73
页数:7
相关论文
共 41 条
[1]   Superior thermal conductivity of single-layer graphene [J].
Balandin, Alexander A. ;
Ghosh, Suchismita ;
Bao, Wenzhong ;
Calizo, Irene ;
Teweldebrhan, Desalegne ;
Miao, Feng ;
Lau, Chun Ning .
NANO LETTERS, 2008, 8 (03) :902-907
[2]  
Burchardt M, 2000, CLIN CHEM, V46, P595
[3]   Photodynamic Diagnosis of Non-muscle-invasive Bladder Cancer with Hexaminolevulinate Cystoscopy: A Meta-analysis of Detection and Recurrence Based on Raw Data [J].
Burger, Maximilian ;
Grossman, H. Barton ;
Droller, Michael ;
Schmidbauer, Joerg ;
Hermann, Gregers ;
Dragoescu, Octavian ;
Ray, Eleanor ;
Fradet, Yves ;
Karl, Alexander ;
Burgues, Juan Pablo ;
Witjes, J. Alfred ;
Stenzl, Arnulf ;
Jichlinski, Patrice ;
Jocham, Dieter .
EUROPEAN UROLOGY, 2013, 64 (05) :846-854
[4]   Ultrasensitive electrochemical immunoassay for BRCA1 using BMIM•BF4-coated SBA-15 as labels and functionalized graphene as enhancer [J].
Cai, Yanyan ;
Li, He ;
Du, Bin ;
Yang, Minghui ;
Li, Yan ;
Wu, Dan ;
Zhao, Yanfang ;
Dai, Yuxue ;
Wei, Qin .
BIOMATERIALS, 2011, 32 (08) :2117-2123
[5]   Successively amplified electrochemical immunoassay based on biocatalytic deposition of silver nanoparticles and silver enhancement [J].
Chen, Zhao-Peng ;
Peng, Zhao-Feng ;
Luo, Yan ;
Qu, Bo ;
Jiang, Jian-Hui ;
Zhang, Xiao-Bing ;
Shen, Guo-Li ;
Yu, Ru-Qin .
BIOSENSORS & BIOELECTRONICS, 2007, 23 (04) :485-491
[6]   Unprecedented high plasmonic sensitivity of substrates based on gold nanoparticles [J].
da Silva, Cleiser T. P. ;
Monteiro, Johny P. ;
Radovanovic, Eduardo ;
Girotto, Emerson M. .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 191 :152-157
[7]   In Vivo Bladder Cancer Diagnosis by High-Volume Raman Spectroscopy [J].
Draga, Ronald O. P. ;
Grimbergen, Matthijs C. M. ;
Vijverberg, Peter L. M. ;
van Swol, Christiaan F. P. ;
Jonges, Trudy G. N. ;
Kummer, J. Alain ;
Bosch, J. L. H. Ruud .
ANALYTICAL CHEMISTRY, 2010, 82 (14) :5993-5999
[8]   CONTROLLED NUCLEATION FOR REGULATION OF PARTICLE-SIZE IN MONODISPERSE GOLD SUSPENSIONS [J].
FRENS, G .
NATURE-PHYSICAL SCIENCE, 1973, 241 (105) :20-22
[9]  
Gan N, 2007, CHINESE J ANAL CHEM, V35, P1553
[10]   Comparative evaluation of the BTAstat test, NMP22, and voided urine cytology in the detection of primary and recurrent bladder tumors [J].
Giannopoulos, A ;
Manousakas, T ;
Mitropoulos, D ;
Botsoli-Stergiou, E ;
Constantinides, C ;
Giannopoulou, M ;
Choremi-Papadopoulou, H .
UROLOGY, 2000, 55 (06) :871-875