Current applications of robotics in spine surgery: a systematic review of the literature

被引:153
作者
Joseph, Jacob R. [1 ]
Smith, Brandon W. [1 ]
Liu, Xilin [1 ]
Park, Paul [1 ]
机构
[1] Univ Michigan, Dept Neurosurg, 1500 East Med Ctr Dr,Rm 3553 TC, Ann Arbor, MI 48109 USA
关键词
surgical robotics; spine surgery; Mazor; Renaissance; SpineAssist; ROSA; PEDICLE SCREW PLACEMENT; RADIATION-EXPOSURE; LEARNING-CURVE; LUMBAR SPINE; C-ARM; ACCURACY; FLUOROSCOPY; GUIDANCE; NAVIGATION; INSERTION;
D O I
10.3171/2017.2.FOCUS16544
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE Surgical robotics has demonstrated utility across the spectrum of surgery. Robotics in spine surgery, however, remains in its infancy. Here, the authors systematically review the evidence behind robotic applications in spinal instrumentation. METHODS This systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. Relevant studies (through October 2016) that reported the use of robotics in spinal instrumentation were identified from a search of the PubMed database. Data regarding the accuracy of screw placement, surgeon learning curve, radiation exposure, and reasons for robotic failure were extracted. RESULTS Twenty-five studies describing 2 unique robots met inclusion criteria. Of these, 22 studies evaluated accuracy of spinal instrumentation. Although grading of pedicle screw accuracy was variable, the most commonly used method was the Gertzbein and Robbins system of classification. In the studies using the Gertzbein and Robbins system, accuracy (Grades A and B) ranged from 85% to 100%. Ten studies evaluated radiation exposure during the procedure. In studies that detailed fluoroscopy usage, overall fluoroscopy times ranged from 1.3 to 34 seconds per screw. Nine studies examined the learning curve for the surgeon, and 12 studies described causes of robotic failure, which included registration failure, soft-tissue hindrance, and lateral skiving of the drill guide. CONCLUSIONS Robotics in spine surgery is an emerging technology that holds promise for future applications. Surgical accuracy in instrumentation implanted using robotics appears to be high. However, the impact of robotics on radiation exposure is not clear and seems to be dependent on technique and robot type.
引用
收藏
页数:8
相关论文
共 41 条
[1]   Miniature robotic guidance for spine surgery - introduction of a novel system and analysis of challenges encountered during the clinical development phase at two spine centres [J].
Barzilay, Y. ;
Liebergall, M. ;
Fridlander, A. ;
Knoller, N. .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2006, 2 (02) :146-153
[2]  
Bederman SS, 2016, CLIN SPINE SURG
[3]   Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion [J].
Bindal, Rajesh K. ;
Glaze, Sharon ;
Ognoskie, Meghann ;
Tunner, Van ;
Malone, Robert ;
Ghosh, Subrata .
JOURNAL OF NEUROSURGERY-SPINE, 2008, 9 (06) :570-573
[4]   Minimally invasive transforaminal lumbar interbody fusion with the ROSATM Spine robot and intraoperative flat-panel CT guidance [J].
Chenin, Louis ;
Peltier, Johann ;
Lefranc, Michel .
ACTA NEUROCHIRURGICA, 2016, 158 (06) :1125-1128
[5]   Clinical Acceptance and Accuracy Assessment of Spinal Implants Guided With SpineAssist Surgical Robot Retrospective Study [J].
Devito, Dennis P. ;
Kaplan, Leon ;
Dietl, Rupert ;
Pfeiffer, Michael ;
Horne, Dale ;
Silberstein, Boris ;
Hardenbrook, Mitchell ;
Kiriyanthan, George ;
Barzilay, Yair ;
Bruskin, Alexander ;
Sackerer, Dieter ;
Alexandrovsky, Vitali ;
Stueer, Carsten ;
Burger, Ralf ;
Maeurer, Johannes ;
Gordon, Donald G. ;
Schoenmayr, Robert ;
Friedlander, Alon ;
Knoller, Nachshon ;
Schmieder, Kirsten ;
Pechlivanis, Ioannis ;
Kim, In-Se ;
Meyer, Bernhard ;
Shoham, Moshe .
SPINE, 2010, 35 (24) :2109-2115
[6]  
Dreval' O N, 2014, Zh Vopr Neirokhir Im N N Burdenko, V78, P14
[7]   ACCURACY OF PEDICULAR SCREW PLACEMENT INVIVO [J].
GERTZBEIN, SD ;
ROBBINS, SE .
SPINE, 1990, 15 (01) :11-14
[8]   Assessment of the surgeon radiation exposure during a minimally invasive TLIF: Comparison between fluoroscopy and O-arm system [J].
Grelat, M. ;
Zairi, F. ;
Quidet, M. ;
Marinho, P. ;
Allaoui, M. ;
Assaker, R. .
NEUROCHIRURGIE, 2015, 61 (04) :255-259
[9]   Robotic assisted surgeries for the treatment of spine tumors [J].
Hu, Xiaobang ;
Scharschmidt, Thomas J. ;
Ohnmeiss, Donna D. ;
Lieberman, Isador H. .
INTERNATIONAL JOURNAL OF SPINE SURGERY, 2015, 9
[10]   What Is the Learning Curve for Robotic-assisted Pedicle Screw Placement in Spine Surgery? [J].
Hu, Xiaobang ;
Lieberman, Isador H. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (06) :1839-1844