Assay of coenzyme Q10 in plasma by a single dilution step

被引:117
作者
Mosca, F [1 ]
Fattorini, D
Bompadre, S
Littarru, GP
机构
[1] Univ Ancona, Fac Med, Inst Biochem, I-60131 Ancona, Italy
[2] Univ Ancona, Fac Med, Inst Biomed Sci, I-60131 Ancona, Italy
关键词
coenzyme Q(10); plasma; dilution; direct extraction; HPLC; UV detection; stability;
D O I
10.1006/abio.2002.5653
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new method is described for determining coenzyme Q(10) (CoQ(10)) in plasma. The method is based on oxidation of CoQ(10) in the sample by treating it with para-benzoquinone followed by extraction with 1-propanol and direct injection into the HPLC apparatus. This method achieves a linear detector response for peak area measurements over the concentration range of 0.05-3.47 muM. Diode array analysis of the peak was consistent with CoQ(10) spectrum. Supplementation of the samples with known amounts of CoQ(10) yielded a quantitative recovery of 96-98.5%; the method showed a level of quantitation of 1.23 nmol per HPLC injection (200 mul of propanol extract containing 33.3 mul of plasma). A correlation of r = 0.99 (P < 0.0001) was found with a reference electrochemical detection method. Within run precision showed a CV% of 1.6 for samples approaching normal values (1.02 muM). Day-today precision was also close to 2%. (C) 2002 Elsevier Science (USA).
引用
收藏
页码:49 / 54
页数:6
相关论文
共 13 条
[1]  
Alleva R, 1997, MOL ASPECTS MED, V18, pS105
[2]   DETERMINATION OF COENZYME-Q10, ALPHA-TOCOPHEROL AND CHOLESTEROL IN BIOLOGICAL SAMPLES BY COUPLED-COLUMN LIQUID-CHROMATOGRAPHY WITH COULOMETRIC AND ULTRAVIOLET DETECTION [J].
EDLUND, PO .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 425 (01) :87-97
[3]  
Finckh B, 1999, METHOD ENZYMOL, V299, P341
[4]   Monitoring of ubiquinol-10, ubiquinone-10, carotenoids, and tocopherols in neonatal plasma microsamples using high-performance liquid chromatography with coulometric electrochemical detection [J].
Finckh, B ;
Kontush, A ;
Commentz, J ;
Hubner, C ;
Burdelski, M ;
Kohlschutter, A .
ANALYTICAL BIOCHEMISTRY, 1995, 232 (02) :210-216
[5]   IMPROVED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF COENZYME-Q10 IN PLASMA [J].
GROSSI, G ;
BARGOSSI, AM ;
FIORELLA, PL ;
PIAZZI, S ;
BATTINO, M ;
BIANCHI, GP .
JOURNAL OF CHROMATOGRAPHY, 1992, 593 (1-2) :217-226
[6]  
Lagendijk J, 1996, J LIPID RES, V37, P67
[7]   QUANTITATIVE-DETERMINATION OF VITAMIN-E AND OXIDIZED AND REDUCED COENZYME-Q BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH IN-LINE ULTRAVIOLET AND ELECTROCHEMICAL DETECTION [J].
LANG, JK ;
PACKER, L .
JOURNAL OF CHROMATOGRAPHY, 1987, 385 :109-117
[8]  
LITTARRU GP, 1991, BIOMED CLIN, V6, P167
[9]  
Mortensen SA, 1997, MOL ASPECTS MED, V18, pS137
[10]   DETERMINATION OF REDUCED AND TOTAL UBIQUINONES IN BIOLOGICAL-MATERIALS BY LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
OKAMOTO, T ;
FUKUNAGA, Y ;
IDA, Y ;
KISHI, T .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 430 (01) :11-19