Selective and sensitive fluorescent turn-off chemosensors for Fe3+

被引:38
作者
Fu, Li [1 ,2 ]
Mei, Jie [1 ,2 ]
Zhang, Ji-Tao [1 ,2 ]
Liu, Yi [1 ,2 ]
Jiang, Feng-Lei [1 ,2 ]
机构
[1] Wuhan Univ, Coll Chem & Mol Sci, State Key Lab Virol, Wuhan 430072, Peoples R China
[2] Wuhan Univ, Coll Chem & Mol Sci, Minist Educ, Key Lab Analyt Chem Biol & Med, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
l-histidine; chemosensor; anthracene; dansyl; Fe3+; SENSORS; BINDING; RECOGNITION; COPPER(II); MECHANISMS; PROBES; CELLS; WATER; ACIDS; BASE;
D O I
10.1002/bio.2406
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two novel chemosensors (2a and 2b) were synthesized by facile condensation of the binding unit (l-histidine) and the fluorophores (anthracene and dansyl groups). Both of them displayed high selectivity and sensitivity towards Fe3+ over other metal ions in aqueous solution. (3+) that would lead to fluorescence quenching of the fluorophores when Fe3+ was bound to the recognition units. l-histidine was a good coordination motif for Fe3+ and both the anthracene and dansyl groups can sensitively report the sensing information. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:602 / 606
页数:5
相关论文
共 28 条
[1]   A New Selective Chromogenic and Turn-On Fluorogenic Probe for Copper(II) in Water-Acetonitrile 1:1 Solution [J].
Ballesteros, Eduardo ;
Moreno, Daniel ;
Gomez, Teresa ;
Rodriguez, Teresa ;
Rojo, Josefa ;
Garcia-Valverde, Maria ;
Torroba, Tomas .
ORGANIC LETTERS, 2009, 11 (06) :1269-1272
[2]   A two-channel molecular dosimeter for the optical detection of copper(II) [J].
Boiocchi, M ;
Fabbrizzi, L ;
Licchelli, M ;
Sacchi, D ;
Vázquez, M ;
Zampa, C .
CHEMICAL COMMUNICATIONS, 2003, (15) :1812-1813
[3]   Iron deficiency and erythropoiesis: New diagnostic approaches [J].
Brugnara, C .
CLINICAL CHEMISTRY, 2003, 49 (10) :1573-1578
[4]   Amplified nitric oxide photorelease in DNA proximity [J].
Callari, Fiorella L. ;
Sortino, Salvatore .
CHEMICAL COMMUNICATIONS, 2008, (17) :1971-1973
[5]   DNA-metal base pairs [J].
Clever, Guido H. ;
Kaul, Corinna ;
Carell, Thomas .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (33) :6226-6236
[6]   Signaling recognition events with fluorescent sensors and switches [J].
de Silva, AP ;
Gunaratne, HQN ;
Gunnlaugsson, T ;
Huxley, AJM ;
McCoy, CP ;
Rademacher, JT ;
Rice, TE .
CHEMICAL REVIEWS, 1997, 97 (05) :1515-1566
[7]   Fluoro- and Chromogenic Chemodosimeters for Heavy Metal Ion Detection in Solution and Biospecimens [J].
Duong Tuan Quang ;
Kim, Jong Seung .
CHEMICAL REVIEWS, 2010, 110 (10) :6280-6301
[8]   Solvent Dependent Fluorescent Properties of a 1,2,3-Triazole Linked 8-Hydroxyquinoline Chemosensor: Tunable Detection from Zinc(II) to Iron(III) in the CH3CN/H2O System [J].
Hao, Erhong ;
Meng, Ting ;
Zhang, Min ;
Pang, Weidong ;
Zhou, Yunyou ;
Jiao, Lijuan .
JOURNAL OF PHYSICAL CHEMISTRY A, 2011, 115 (29) :8234-8241
[9]   Coumarin-Derived Cu2+-Selective Fluorescence Sensor: Synthesis, Mechanisms, and Applications in Living Cells [J].
Jung, Hyo Sung ;
Kwon, Pil Seung ;
Lee, Jeong Won ;
Kim, Jae Il ;
Hong, Chang Seop ;
Kim, Jong Wan ;
Yan, Shihai ;
Lee, Jin Yong ;
Lee, Jung Hwa ;
Joo, Taiha ;
Kim, Jong Seung .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (05) :2008-2012
[10]   INTERACTION OF HYDROPHOBIC PROBES WITH SERUM-ALBUMIN - INFLUENCE OF THE SIDE-CHAIN AND EXCIPLEX FORMATION AT THE BINDING-SITE [J].
KUMAR, CV ;
TOLOSA, LM .
JOURNAL OF PHYSICAL CHEMISTRY, 1993, 97 (51) :13914-13919