Ectasia after laser in situ keratomileusis

被引:54
作者
Rabinowitz, Yaron S.
机构
[1] Cedars Sinai Med Ctr, Los Angeles, CA 90048 USA
[2] Univ Calif Los Angeles, Sch Med, Dept Ophthalmol, Los Angeles, CA 90024 USA
关键词
corneal biomechanics; ectasia; forme fruste keratoconus; LASIK; Orbscan;
D O I
10.1097/01.icu.0000243015.51886.3a
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose of review The potential for litigation has resulted in increased interest in ectasia after laser in situ keratomileusis. This article summarizes papers written during this past year on this subject. Recent findings A panel of refractive surgery experts have summarized the current state of knowledge on this subject and provided guidelines to minimize risk. Because ectasia may occur in the absence of risk factors, there may be corneas with biomechanical factors not detectable with present technology which are at risk. Several articles point out the limitations of the Orbscan (Bausch & Lomb, Rochester, New York, USA), in particular its accuracy and reproducibility with regard to data generated from the posterior surface of the cornea. A biomechanical model of the cornea is proposed which suggests that each cornea's response to laser in situ keratomileusis is unique. Several case reports are also reviewed which provide insight into pathogenesis and potential new treatment options; these include reports on histopathology, topographic pseudokeratectasia, ectasia from transient raised intraocular pressure, poor response to laser in situ keratomileusis after incisional surgery, intracorneal rings, collagen cross-linking and conductive keratoplasty to stabilize and sphericize the cornea with ectasia. Summary Our knowledge about ectasia is still in evolution. Insights into the biomechanics and genetics of the cornea may allow us to further reduce its occurrence.
引用
收藏
页码:421 / 426
页数:6
相关论文
共 25 条
[1]   Corneal modeling of keratoconus by conductive keratoplasty [J].
Alió, JL ;
Claramonte, PJ ;
Cáliz, A ;
Ramzy, MI .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :190-197
[2]   Keratoconus and corneal ectasia after LASIK [J].
Binder, PS ;
Lindstrom, RL ;
Stulting, RD ;
Donnenfeld, E ;
Wu, H ;
McDonnell, P ;
Rabinowitz, Y .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (11) :2035-2038
[3]   Assessing the accuracy of Orbscan II post-LASIK: apparent keratectasia is paradoxically associated with anterior chamber depth reduction in successful procedures [J].
Cairns, G ;
Ormonde, SE ;
Gray, T ;
Hadden, OB ;
Morris, T ;
Ring, P ;
McGhee, CNJ .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 33 (02) :147-152
[4]   Orbscan computerized topography: Attributes, applications, and limitations [J].
Cairns, G ;
McGhee, CNJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :205-220
[5]  
Dupps WJ, 2005, J REFRACT SURG, V21, P186
[6]   Model for nonectatic increase in posterior corneal elevation after ablative procedures [J].
Grzybowski, DM ;
Roberts, CJ ;
Mahmoud, AM ;
Chang, JS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :72-81
[7]  
Guell Jose L, 2005, Curr Opin Ophthalmol, V16, P260
[8]  
Guirao A, 2005, J REFRACT SURG, V21, P176
[9]   Reversal of laser in situ keratomileusis-induced ectasia with intraocular pressure reduction [J].
Hiatt, JA ;
Wachler, BSB ;
Grant, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (08) :1652-1655
[10]   Laser in situ keratomileusis for primary hyperopia [J].
Jin, GJC ;
Lyle, WA ;
Merkley, KH .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (04) :776-784