Objective measurement of adherence to wearing foot orthoses using an embedded temperature sensor

被引:17
作者
Menz, Hylton B. [1 ,2 ]
Bonanno, Daniel R. [1 ,2 ]
机构
[1] La Trobe Univ, Coll Sci Hlth & Engn, Sch Allied Hlth Human Serv & Sport, Discipline Podiatry, Melbourne, Vic 3086, Australia
[2] La Trobe Univ, Coll Sci Hlth & Engn, La Trobe Sport & Exercise Med Res Ctr, Sch Allied Hlth Human Serv & Sport, Melbourne, Vic 3086, Australia
基金
英国医学研究理事会;
关键词
Orthosis; Footwear; Adherence; Temperature; COMFORT; DEVICES;
D O I
10.1016/j.medengphy.2020.12.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this study was to evaluate the validity of a temperature sensor for the measurement of adherence to wearing foot orthoses. Ten participants were provided with foot orthoses containing an embedded temperature sensor and wore the orthoses for a randomly-determined duration over a five-day period. Sensor-detected wear time was compared to a reference standard (objectively measured wear time using a smart-phone application). Ambient temperature and physical activity were recorded with a temperature gauge and wearable activity tracker, respectively. A simple peak detection algorithm which identified the largest one-minute changes in sensor temperature provided highly accurate wear time values (r = 0.999, coefficient of variation = 0.2%). Ambient temperature and physical activity did not significantly influence temperature sensor scores. These findings demonstrate that the temperature sensor provides accurate foot orthosis wear time data and may therefore be a useful tool for documenting adherence in clinical practice and intervention studies. (C) 2020 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 27 条
[1]  
[Anonymous], BMJ OPEN SPORT EXERC
[2]   Testing thermal comfort of trekking boots: An objective and subjective evaluation [J].
Arezes, P. M. ;
Neves, M. M. ;
Teixeira, S. F. ;
Leao, C. P. ;
Cunha, J. L. .
APPLIED ERGONOMICS, 2013, 44 (04) :557-565
[3]   Effectiveness of custom-made foot orthoses for treating forefoot pain: a systematic review [J].
Arias-Martin, Isabel ;
Reina-Bueno, Maria ;
Munuera-Martinez, Pedro V. .
INTERNATIONAL ORTHOPAEDICS, 2018, 42 (08) :1865-1875
[4]  
Armstrong DG, 1997, J REHABIL RES DEV, V34, P317
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Effectiveness of foot orthoses and shock-absorbing insoles for the prevention of injury: a systematic review and meta-analysis [J].
Bonanno, Daniel R. ;
Landorf, Karl B. ;
Munteanu, Shannon E. ;
Murley, George S. ;
Menz, Hylton B. .
BRITISH JOURNAL OF SPORTS MEDICINE, 2017, 51 (02) :86-+
[7]   New Monitoring Technology to Objectively Assess Adherence to Prescribed Footwear and Assistive Devices During Ambulatory Activity [J].
Bus, Sicco A. ;
Waaijman, Roelof ;
Nolet, Frans .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (11) :2075-2079
[8]   Cohort Randomised Controlled Trial of a Multifaceted Podiatry Intervention for the Prevention of Falls in Older People (The REFORM Trial) [J].
Cockayne, Sarah ;
Adamson, Joy ;
Clarke, Arabella ;
Corbacho, Belen ;
Fairhurst, Caroline ;
Green, Lorraine ;
Hewitt, Catherine E. ;
Hicks, Kate ;
Kenan, Anne-Maree ;
Lamb, Sarah E. ;
McIntosh, Caroline ;
Menz, Hylton B. ;
Redmond, Anthony C. ;
Richardson, Zoe ;
Rodgers, Sara ;
Vernon, Wesley ;
Watson, Judith ;
Torgerson, David J. .
PLOS ONE, 2017, 12 (01)
[9]  
Ehrmann Dominic, 2018, J Diabetes Sci Technol, V12, P695, DOI 10.1177/1932296817747618
[10]   Compliance with wearing an abduction brace after arthroscopic rotator cuff repair: A prospective, sensor-controlled study [J].
Grubhofer, Florian ;
Gerber, Christian ;
Meyer, Dominik C. ;
Wieser, Karl ;
Ernstbrunner, Lukas ;
Catanzaro, Sabrina ;
Bouaicha, Samy .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2019, 43 (04) :440-446