Simultaneous quantitation of sphingoid bases by UPLC-ESI-MS/MS with identical 13C-encoded internal standards

被引:36
作者
Mirzaian, M. [1 ]
Wisse, P. [2 ]
Ferraz, M. J. [1 ]
Marques, A. R. A. [3 ]
Gaspar, P. [4 ]
Oussoren, S. V. [1 ]
Kytidou, K. [1 ]
Codee, J. D. C. [2 ]
van der Marel, G. [2 ]
Overkleeft, H. S. [2 ]
Aerts, J. M. [1 ]
机构
[1] Leiden Univ, Dept Med Biochem, Leiden Inst Chem, NL-2300 RA Leiden, Netherlands
[2] Leiden Univ, Leiden Inst Chem, Dept Bioorgan Synth, NL-2300 RA Leiden, Netherlands
[3] Univ Kiel, Dept Biochem, Kiel, Germany
[4] Natl Inst Hlth Dr Ricardo Jorge, Dept Human Genet, Newborn Screening Metab & Genet Unit, Oporto, Portugal
关键词
Sphingoid bases; Fabry disease; Gaucher disease; C-13-encoded internal standards; Mass spectrometry; Quantification; FABRY-DISEASE; SIMULTANEOUS QUANTIFICATION; MASS-SPECTROMETRY; GLUCOSYLCERAMIDE; PLASMA; CERAMIDE; GLOBOTRIAOSYLSPHINGOSINE; GALACTOSYLCERAMIDE; EXTRACTION; URINE;
D O I
10.1016/j.cca.2017.01.014
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Free sphingoid bases (lysosphingolipids) of primary storage sphingolipids are increased in tissues and plasma of several sphingolipidoses. As shown earlier by us, sphingoid bases can be accurately quantified using UPLC-ESI-MS/MS, particularly in combination with identical C-13-encoded internal standards. The feasibility of simultaneous quantitation of sphingoid bases in plasma specimens spiked with a mixture of such standards is here described. The sensitivity and linearity of detection is excellent for all examined sphingoid bases (sphingosine, sphinganine, hexosyl-sphingosine (glucosylsphingosine), hexosyl(2)-sphingosine (lactosylsphingosine), hexosyl(3)-sphingosine (globotriaosylsphingosine), phosphorylcholine-sphingosine) in the relevant concentration range and the measurements show very acceptable intra- and inter-assay variation (< 10% average). Plasma samples of a series of male and female Gaucher Disease and Fabry Disease patients were analyzed with the multiplex assay. The obtained data compare well to those earlier determined for plasma globotriaosylsphingosine and glucosylsphingosine in GD and FD patients. The same approach can be also applied to measure sphingolipids in the same sample. Following extraction of sphingolipids from the same sample these can be converted to sphingoid bases by microwave exposure and subsequently quantified using C-13-encoded internal standards. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:178 / 184
页数:7
相关论文
共 29 条
  • [1] Simultaneous Analysis of Vanillin and Coumarin in Mangrove Plants and Commercial Food Products Using UPLC-ESI-MS/MS
    Dahibhate, Nilesh Lakshman
    Kumar, Devendra
    Kumar, Kundan
    CURRENT ANALYTICAL CHEMISTRY, 2020, 16 (06) : 768 - 777
  • [2] Simultaneous Detection of 14 Microcystin Congeners from Tissue Samples Using UPLC-ESI-MS/MS and Two Different Deuterated Synthetic Microcystins as Internal Standards
    Altaner, Stefan
    Puddick, Jonathan
    Fessard, Valerie
    Feurstein, Daniel
    Zemskov, Ivan
    Wittmann, Valentin
    Dietrich, Daniel R.
    TOXINS, 2019, 11 (07)
  • [3] A novel UPLC-ESI-MS/MS method for the quantitation of disulfiram, its role in stabilized plasma and its application
    Zhang, Ling
    Jiang, Ying
    Jing, Guanghui
    Tang, Yilin
    Chen, Xi
    Yang, Dan
    Zhang, Yu
    Tang, Xing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 937 : 54 - 59
  • [4] Rapid simultaneous determination of herbicides in human serum by UPLC-ESI-MS
    Dong, Xinfeng
    Shi, Zhihong
    Liang, Shuxuan
    Sun, Hanwen
    ANALYTICAL METHODS, 2014, 6 (17) : 6939 - 6947
  • [5] Accurate quantification of sphingosine-1-phosphate in normal and Fabry disease plasma, cells and tissues by LC-MS/MS with 13C-encoded natural SIP as internal standard
    Mirzaian, Mina
    Wisse, Patrick
    Ferraz, Maria J.
    Marques, Andre R. A.
    Gabriel, Tanit L.
    van Roomen, Cindy P. A. A.
    Ottenhoff, Roelof
    van Eijk, Marco
    Codee, Jeroen D. C.
    van der Marel, Gijsbert A.
    Overkleeft, Herman S.
    Aerts, Johannes M.
    CLINICA CHIMICA ACTA, 2016, 459 : 36 - 44
  • [6] Quick and Sensitive UPLC-ESI-MS/MS Method for Simultaneous Estimation of Sofosbuvir and Its Metabolite in Human Plasma
    Semreen, Mohammad H.
    Alniss, Hasan Y.
    Mousa, Muath K.
    Aboul-Enein, Hassan Y.
    MOLECULES, 2019, 24 (07)
  • [7] A rapid analytical method for characterization and simultaneous quantitative determination of phytoconstituents in Piper betle landraces using UPLC-ESI-MS/MS
    Pandey, Renu
    Chandra, Preeti
    Srivastva, Mukesh
    Arya, K. R.
    Shukla, Praveen K.
    Kumar, Brijesh
    ANALYTICAL METHODS, 2014, 6 (18) : 7349 - 7360
  • [8] Simultaneous Determination of Tobacco Alkaloids, Tobacco-Specific Nitrosamines, and Solanesol in Consumer Products Using UPLC-ESI-MS/MS
    Shifflett, John R.
    Watson, Leah
    McNally, Devin J.
    Bezabeh, Dawit Z.
    CHROMATOGRAPHIA, 2018, 81 (03) : 517 - 523
  • [9] Fabric phase sorptive extraction coupled with UPLC-ESI-MS/MS method for fast and sensitive quantitation of tadalafil in a bioequivalence study
    Ahmed, Sameh A.
    Alalawi, Ali M.
    Shehata, Ahmed M.
    Alqurshi, Abdulmalik A.
    Alahmadi, Yaser M.
    Ali, Hany S. M.
    SAUDI PHARMACEUTICAL JOURNAL, 2022, 30 (08) : 1143 - 1152
  • [10] Parallel artificial liquid membrane extraction coupled with UPLC-ESI-MS/ MS method for high-throughput quantitation of repaglinide in diabetic patients
    Ahmed, Sameh A.
    Abdallah, Nehad A.
    Almaghrabi, Mohammed
    Alahmadi, Yaser M.
    TALANTA, 2024, 269