Potentiometric Anion Selectivity and Analytical Applications of Polymer Membrane Electrodes Based on Novel Mn(III)- and Mn(IV)-Salophen Complexes

被引:14
作者
Abdel-Haleem, Fatehy M. [1 ]
Badr, Ibrahim H. A. [2 ]
Rizk, Mahmoud S. [1 ]
机构
[1] Cairo Univ, Dept Chem, Fac Sci, Cairo, Egypt
[2] Ain Shams Univ, Dept Chem, Fac Sci, Cairo, Egypt
关键词
Thiocyanate sensor; PVC electrode; salophen complexes; potentiometry; SCHIFF-BASE; RESPONSE PROPERTIES; NEUTRAL CARRIERS; THIOCYANATE; IONOPHORES; COBALT; DERIVATIVES; SENSOR; FILMS; IONS;
D O I
10.1002/elan.201600335
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New Mn(III)-L and Mn(IV)-L complexes were prepared from the highly lipophilic salophen ligand (L): phenol 2,2'-[(4,5-dimethyl-1,2-phenylene)bis[(E)-nitrilomethylidyne]]bis[4,6-bis(1,1-dimethylethyl). The prepared complexes were fully characterized and used for the construction of thiocyanate membrane electrodes. Optimized membrane electrodes contained 33.0 mg PVC, 66.0 mg o-nitrophenyloctylether, 50 or 5 (mole%) tetrakis(trifluoromethyl) phenyl borate and 1 mg Mn(III)-L (sensor 2) or Mn-(IV)-L (sensor 12), respectively. Such electrodes exhibited linear responses toward thiocynate in a concentration range of 10(-1)-10(-5) M and detection limits of 8.3 x 10(-6), 8.9 x 10(-6) M for sensor 2 and 12, respectively. Optimized membrane electrodes exhbited high selectivty toward thiocayante compared to more lipophilic anions. The observed thiocyanate selectivity of the optimized membranes was confirmed by formation constant calculations for Mn(III)-L and Mn(IV)-L with SCN-, beta=10(14.1) and 10(12.5), which was measured potentiometrically using the sandwich membrane method. Furthermore, computational study using DFT calculations was performed to at DFT/B3LYP level of theory to confirm the observed selectivity data. The response times were 3 and 0.5 min for low and high concentrations. The lifetimes of the optimized electrodes were similar to 4-6 weeks. The analytical utility of the optimized membrane electrodes was demonstrated by the analysis of thiocyanate level in different saliva samples.
引用
收藏
页码:2922 / 2929
页数:8
相关论文
共 42 条
[11]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[12]  
BEDTSEN AB, 1991, ANALYST, V116, P647
[13]   The determination of thiocyanate in blood serum [J].
Bowler, RG .
BIOCHEMICAL JOURNAL, 1944, 38 :385-388
[14]   SELECTIVE ELECTRODES FOR SILVER AND ANIONS BASED ON POLYMERIC MEMBRANES CONTAINING COMPLEXES OF TRIISOBUTYLPHOSPHINE SULFIDE WITH SILVER [J].
BRICKER, J ;
DAUNERT, S ;
BACHAS, LG ;
VALIENTE, M .
ANALYTICAL CHEMISTRY, 1991, 63 (15) :1585-1589
[15]   MN(III) PORPHYRIN-BASED THIOCYANATE-SELECTIVE MEMBRANE ELECTRODES - CHARACTERIZATION AND APPLICATION IN FLOW-INJECTION DETERMINATION OF THIOCYANATE IN SALIVA [J].
BROWN, DV ;
CHANIOTAKIS, NA ;
LEE, IH ;
MA, SC ;
PARK, SB ;
MEYERHOFF, ME ;
NICK, RJ ;
GROVES, JT .
ELECTROANALYSIS, 1989, 1 (06) :477-484
[16]   Ion-selective electrodes for thiocyanate based on the dinuclear Zinc(II) complex of a Bis-N,O-bidentate Schiff base [J].
Bühlmann, P ;
Yahya, L ;
Enderes, R .
ELECTROANALYSIS, 2004, 16 (12) :973-978
[17]   INFLUENCE OF PORPHYRIN STRUCTURE ON ANION SELECTIVITIES OF MANGANESE(III) PORPHYRIN BASED MEMBRANE ELECTRODES [J].
CHANIOTAKIS, NA ;
CHASSER, AM ;
MEYERHOFF, ME ;
GROVES, JT .
ANALYTICAL CHEMISTRY, 1988, 60 (02) :185-188
[18]   Characterization of Salophen Co(III) Acetate Ionophore for Nitrite Recognition [J].
Crespo, Gaston A. ;
Afshar, Majid Ghahraman ;
Barrabes, Noelia ;
Pawlak, Marcin ;
Bakker, Eric .
ELECTROCHIMICA ACTA, 2015, 179 :16-23
[19]   ANION-SELECTIVE ELECTRODES BASED ON ELECTROPOLYMERIZED PORPHYRIN FILMS [J].
DAUNERT, S ;
WALLACE, S ;
FLORIDO, A ;
BACHAS, LG .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1676-1679
[20]  
Han W.S., 2011, J AM ANAL CHEM, V2, P731