Potentiometric Anion Selectivity and Analytical Applications of Polymer Membrane Electrodes Based on Novel Mn(III)- and Mn(IV)-Salophen Complexes

被引:14
作者
Abdel-Haleem, Fatehy M. [1 ]
Badr, Ibrahim H. A. [2 ]
Rizk, Mahmoud S. [1 ]
机构
[1] Cairo Univ, Dept Chem, Fac Sci, Cairo, Egypt
[2] Ain Shams Univ, Dept Chem, Fac Sci, Cairo, Egypt
关键词
Thiocyanate sensor; PVC electrode; salophen complexes; potentiometry; SCHIFF-BASE; RESPONSE PROPERTIES; NEUTRAL CARRIERS; THIOCYANATE; IONOPHORES; COBALT; DERIVATIVES; SENSOR; FILMS; IONS;
D O I
10.1002/elan.201600335
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New Mn(III)-L and Mn(IV)-L complexes were prepared from the highly lipophilic salophen ligand (L): phenol 2,2'-[(4,5-dimethyl-1,2-phenylene)bis[(E)-nitrilomethylidyne]]bis[4,6-bis(1,1-dimethylethyl). The prepared complexes were fully characterized and used for the construction of thiocyanate membrane electrodes. Optimized membrane electrodes contained 33.0 mg PVC, 66.0 mg o-nitrophenyloctylether, 50 or 5 (mole%) tetrakis(trifluoromethyl) phenyl borate and 1 mg Mn(III)-L (sensor 2) or Mn-(IV)-L (sensor 12), respectively. Such electrodes exhibited linear responses toward thiocynate in a concentration range of 10(-1)-10(-5) M and detection limits of 8.3 x 10(-6), 8.9 x 10(-6) M for sensor 2 and 12, respectively. Optimized membrane electrodes exhbited high selectivty toward thiocayante compared to more lipophilic anions. The observed thiocyanate selectivity of the optimized membranes was confirmed by formation constant calculations for Mn(III)-L and Mn(IV)-L with SCN-, beta=10(14.1) and 10(12.5), which was measured potentiometrically using the sandwich membrane method. Furthermore, computational study using DFT calculations was performed to at DFT/B3LYP level of theory to confirm the observed selectivity data. The response times were 3 and 0.5 min for low and high concentrations. The lifetimes of the optimized electrodes were similar to 4-6 weeks. The analytical utility of the optimized membrane electrodes was demonstrated by the analysis of thiocyanate level in different saliva samples.
引用
收藏
页码:2922 / 2929
页数:8
相关论文
共 42 条
[1]   Cationic or anionic sites?: Selectivity optimization of ion-selective electrodes based on charged ionophores [J].
Amemiya, S ;
Bühlmann, P ;
Pretsch, E ;
Rusterholz, B ;
Umezawa, Y .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1618-1631
[2]   PVC-based Mn(III) porphyrin membrane coated graphite electrode for determination of histidine [J].
Amini, MK ;
Shahrokhian, S ;
Tangestaninejad, S .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2502-2505
[3]   Thiocyanate-selective electrodes based on nickel and iron phthalocyanines [J].
Amini, MK ;
Shahrokhian, S ;
Tangestaninejad, S .
ANALYTICA CHIMICA ACTA, 1999, 402 (1-2) :137-143
[4]   PVC-based cobalt and manganese phthalocyanine coated graphite electrodes for determination of thiocyanate [J].
Amini, MK ;
Shahrokhian, S ;
Tangestaninejad, S .
ANALYTICAL LETTERS, 1999, 32 (14) :2737-2750
[5]  
[Anonymous], 1976, Pure and Applied Chemistry, V48, P127, DOI [10.1351/pac197648010127, DOI 10.1351/PAC197648010127]
[6]  
Ardakani M. Mazloum, 2002, Analytica Chimica Acta, V462, P25
[7]   Highly selective optical fluoride ion sensor with submicromolar detection limit based on aluminum(III) octaethylporphyrin in thin polymeric film [J].
Badr, IHA ;
Meyerhoff, ME .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (15) :5318-5319
[8]   Nitrite-selective optical sensors based on organopalladium ionophores [J].
Badr, IHA .
ANALYTICAL LETTERS, 2001, 34 (12) :2019-2034
[9]   POTENTIOMETRIC ANION SELECTIVITY OF POLYMER MEMBRANES DOPED WITH PALLADIUM ORGANOPHOSPHINE COMPLEX [J].
BADR, IHA ;
MEYERHOFF, ME ;
HASSAN, SSM .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2613-2618
[10]   ANION-SELECTIVE MEMBRANE ELECTRODES BASED ON METALLOPORPHYRINS - THE INFLUENCE OF LIPOPHILIC ANIONIC AND CATIONIC SITES ON POTENTIOMETRIC SELECTIVITY [J].
BAKKER, E ;
MALINOWSKA, E ;
SCHILLER, RD ;
MEYERHOFF, ME .
TALANTA, 1994, 41 (06) :881-890