Hybrid system calibration for multidimensional magnetic particle imaging

被引:37
作者
von Gladiss, A. [1 ]
Graeser, M. [1 ]
Szwargulski, P. [2 ,3 ]
Knopp, T. [2 ,3 ]
Buzug, T. M. [1 ]
机构
[1] Univ Lubeck, Inst Med Engn, Lubeck, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Sect Biomed Imaging, Hamburg, Germany
[3] Hamburg Univ Technol, Inst Biomed Imaging, Hamburg, Germany
关键词
system calibration; magnetic particle imaging; background correction; hybrid system matrix; spatial resolution; signal to noise ratio; acquisition time; RECONSTRUCTION; FORMULATION; RESOLUTION; SIGNAL;
D O I
10.1088/1361-6560/aa5340
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic particle imaging visualizes the spatial distribution of superparamagnetic nanoparticles. Because of its key features of excellent sensitivity, high temporal and spatial resolution and biocompatibility of the tracer material it can be used in multiple medical imaging applications. The common reconstruction technique for Lissajous-type trajectories uses a system matrix that has to be previously acquired in a time-consuming calibration scan, leading to long downtimes of the scanning device. In this work, the system matrix is determined by a hybrid approach. Using the hybrid system matrix for reconstruction, the calibration downtime of the scanning device can be neglected. Furthermore, the signal to noise ratio of the hybrid system matrix is much higher, since the size of the required nanoparticle sample can be chosen independently of the desired voxel size. As the signal to noise ratio influences the reconstruction process, the resulting images have better resolution and are less affected by artefacts. Additionally, a new approach is introduced to address the background signal in image reconstruction. The common technique of subtraction of the background signal is replaced by extending the system matrix with an entry that represents the background. It is shown that this approach reduces artefacts in the reconstructed images.
引用
收藏
页码:3392 / 3406
页数:15
相关论文
共 24 条
[1]   Robust uncertainty principles:: Exact signal reconstruction from highly incomplete frequency information [J].
Candès, EJ ;
Romberg, J ;
Tao, T .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (02) :489-509
[2]   Magnetic Particle Imaging With Tailored Iron Oxide Nanoparticle Tracers [J].
Ferguson, R. Matthew ;
Khandhar, Amit P. ;
Kemp, Scott J. ;
Arami, Hamed ;
Saritas, Emine U. ;
Croft, Laura R. ;
Konkle, Justin ;
Goodwill, Patrick W. ;
Halkola, Aleksi ;
Rahmer, Juergen ;
Borgert, Joern ;
Conolly, Steven M. ;
Krishnan, Kannan M. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (05) :1077-1084
[3]   Tomographic imaging using the nonlinear response of magnetic particles [J].
Gleich, B ;
Weizenecker, R .
NATURE, 2005, 435 (7046) :1214-1217
[4]   Multidimensional X-Space Magnetic Particle Imaging [J].
Goodwill, Patrick W. ;
Conolly, Steven M. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (09) :1581-1590
[5]   The X-Space Formulation of the Magnetic Particle Imaging Process: 1-D Signal, Resolution, Bandwidth, SNR, SAR, and Magnetostimulation [J].
Goodwill, Patrick W. ;
Conolly, Steven M. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (11) :1851-1859
[6]   2D Images Recorded With a Single-Sided Magnetic Particle Imaging Scanner [J].
Graefe, Ksenija ;
von Gladiss, Anselm ;
Bringout, Gael ;
Ahlborg, Mandy ;
Buzug, Thorsten M. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (04) :1056-1065
[7]  
Graeser M, 2015, INT WORKSH MAGN PART
[8]  
Graeser M, 2016, PHYS MED BIOL, V62, P3378
[9]  
Graeser M., 2011, BIOMEDICAL TECHNOLOG, V56
[10]  
Gruettner M, 2011, IEEE NUCL SCI CONF R, P2545, DOI 10.1109/NSSMIC.2011.6152687