Performance evaluation of an arched plate solar air heater with porous aluminum wire mesh cylindrical fins

被引:21
作者
Khatri, Rahul [1 ]
Goswami, Shlok [1 ]
Anas, Mohd [1 ]
Sharma, Shubham [1 ]
Agarwal, Satvik [1 ]
Aggarwal, Shivansh [1 ]
机构
[1] Manipal Univ Jaipur, Jaipur 303007, Rajasthan, India
关键词
Solar air heater; Thermal performance; Arched absorber plate; Porous cylindrical wire mesh fins;
D O I
10.1016/j.egyr.2020.11.177
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Solar air heater is used to heat air for space heating and drying process, but its low heat transfers between absorber plate and air account for its low thermal performance. Various surface geometries and fin modifications in a solar air heater have improved its thermal performance. The fabrication and performance evaluation of a solar air heater with an arched wavy absorber plate having porous aluminum wire mesh cylindrical fins attached have been investigated. The arched absorber plate design resulted in an increase in the air turbulence and vortex generation, which leads to the breaking of laminar sub-layer near the surface of the absorber plate and improved the heat transfer. In addition, cylindrical porous wire mesh aluminum fins resulted in an increase in the fin porosity which reduces the pressure drop and improved the thermal performance of the solar air heater. Comparative analysis has been carried for different arrangements at three different fluid flow velocities. The arched wavy absorber plate with fins resulted in better thermal performance with a temperature difference in the range of 55-70 degrees C approx. compared to the other arrangements at a fluid flow velocity of 5 m/s. (C) 2020 TheAuthor(s). Published by Elsevier Ltd.
引用
收藏
页码:627 / 633
页数:7
相关论文
共 13 条
[1]   Energy and exergy analysis of solar air heater having new design absorber plate with conical surface [J].
Abuska, Mesut .
APPLIED THERMAL ENGINEERING, 2018, 131 :115-124
[2]   Optimization of flat plate solar air heaters with ribbed surfaces [J].
Ansari, Mohammad ;
Bazargan, Majid .
APPLIED THERMAL ENGINEERING, 2018, 136 :356-363
[3]   The effect of using transverse fins on a double pass flow solar air heater using wire mesh as an absorber [J].
El-khawajah, M. F. ;
Aldabbagh, L. B. Y. ;
Egelioglu, F. .
SOLAR ENERGY, 2011, 85 (07) :1479-1487
[4]   Performance evaluation of a double pass PV/T solar air heater with and without fins [J].
Kumar, Rakesh ;
Rosen, Marc A. .
APPLIED THERMAL ENGINEERING, 2011, 31 (8-9) :1402-1410
[5]   Performance analysis of trapezoidal corrugated solar air heater with sensible heat storage material [J].
Lakshmi, D. V. N. ;
Layek, Apurba ;
Kumar, P. Muthu .
INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENT IN AIR CONDITIONING AND REFRIGERATION, RAAR 2016, 2017, 109 :463-470
[6]   Comprehensive performance evaluation and parametric studies of single pass solar air heater with fins and baffles attached over the absorber plate [J].
Mohammadi, K. ;
Sabzpooshani, M. .
ENERGY, 2013, 57 :741-750
[7]   Experimental investigation on heat transfer augmentation of solar air heater using shot blasted V-corrugated absorber plate [J].
Poongavanam, Ganesh Kumar ;
Panchabikesan, Karthik ;
Leo, Anto Joseph Deeyoko ;
Ramalingam, Velraj .
RENEWABLE ENERGY, 2018, 127 :213-229
[8]   Comprehensive study on solar air heater with circular and V-type turbulators attached on absorber plate [J].
Rajaseenivasan, T. ;
Srinivasan, S. ;
Srithar, K. .
ENERGY, 2015, 88 :863-873
[9]   Thermohydraulic performance analysis of an arc shape wire roughened solar air heater [J].
Sahu, Mukesh Kumar ;
Prasad, Radha Krishna .
RENEWABLE ENERGY, 2017, 108 :598-614
[10]   A review of artificial roughness geometries employed in solar air heaters [J].
Singh, Inderjeet ;
Singh, Sukhmeet .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 92 :405-425