A high-yield microassembly structure for three-dimensional microelectrode arrays

被引:184
作者
Bai, Q
Wise, KD [1 ]
Anderson, DJ
机构
[1] Univ Michigan, Dept Elect Engn & Comp Sci, Ctr Integrated Sensors & Circuits, Ann Arbor, MI 48109 USA
[2] Guidant Corp, Adv Technol Dept, St Paul, MN 55112 USA
关键词
active recording; microassembly; neural probe; neural recording; neural sensor; orthogonal lead transfers; three-dimensional microstructure;
D O I
10.1109/10.827288
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a practical microassembly process for three-dimensional (3-D) microelectrode arrays for recording and stimulation in the central nervous system (CNS), Orthogonal lead transfers between the micromachined two-dimensional probes and a cortical surface platform are formed by attaching gold beams on the probes to pads on the platform using wire-free ultrasonic bonding. The low profile (150 mu m) outrigger design of the probes allows the bonding of fully assembled high-density arrays, Micromachined assembly tools allow the formation of a full 3-D probe array within 30 min. Arrays having up to 8 x 16 shanks on 200-mu m centers have been realized and used to record cortical single units successfully. Active 3-D probe arrays containing on-chip CMOS signal processing circuitry have also been created using the microassembly approach. In addition, a dynamic insertion technique has been explored to allow the implantation of high-density probe arrays into feline cortex at high-speed and with minimal traumatic injury.
引用
收藏
页码:281 / 289
页数:9
相关论文
共 19 条
[1]  
BAI Q, 1998, SOL STAT SENS ACT WO, P15
[2]  
BAI Q, 1996, SOL STAT SENS ACT WO, P262
[3]  
BIELEN JA, 1996, P 18 ANN INT C IEEE
[4]  
BRAGIN A, 1995, J NEUROSCI, V15, P47
[5]   A SILICON-BASED, 3-DIMENSIONAL NEURAL INTERFACE - MANUFACTURING PROCESSES FOR AN INTRACORTICAL ELECTRODE ARRAY [J].
CAMPBELL, PK ;
JONES, KE ;
HUBER, RJ ;
HORCH, KW ;
NORMANN, RA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (08) :758-768
[6]  
Carter R. R., 1993, IEEE Transactions on Rehabilitation Engineering, V1, P175, DOI 10.1109/86.279266
[7]   A METHOD FOR THE STUDY OF UNDECALCIFIED BONES AND TEETH WITH ATTACHED SOFT-TISSUES - THE SAGE-SCHLIFF (SAWING AND GRINDING) TECHNIQUE [J].
DONATH, K ;
BREUNER, G .
JOURNAL OF ORAL PATHOLOGY & MEDICINE, 1982, 11 (04) :318-326
[8]   FACTORS INFLUENCING THE BIOCOMPATIBILITY OF INSERTABLE SILICON MICROSHAFTS IN CEREBRAL-CORTEX [J].
EDELL, DJ ;
TOI, VV ;
MCNEIL, VM ;
CLARK, LD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (06) :635-643
[9]  
EDWARDS CE, 1997, ABSTR MICR MICR 97, P351
[10]  
FRIESWIJK TA, 1994, P 16 ANN INT C IEEE