Experimental investigation of precast RC interior beam-column-slab joints with grouted spiral-confined lap connection

被引:38
作者
Ma, Cailong
Jiang, Hongbin
Wang, Zhenyu
机构
[1] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Heilongjiang, Peoples R China
[2] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Heilongjiang, Peoples R China
关键词
Precast concrete; Interior beam-column-slab joint; Grouted spiral-confined lap connection; Precast assembling pattern; Seismic performance; SEISMIC PERFORMANCE; BOND BEHAVIOR; SPLICE SLEEVE; PIPE SPLICE; CONCRETE; FRAMES; TESTS; DESIGN; STRENGTH; BRIDGE;
D O I
10.1016/j.engstruct.2019.109317
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The behavior of precast concrete (PC) structures subjected to seismic load depends mainly on the type, location, and reliability of the connections between precast components. To investigate these, the precast beam-column joints are usually tested. However, the research on the seismic performance of the precast beam-column joints containing transverse beams and slabs remains limited and most of the adopted connections are expensive. In this paper, a simple and inexpensive grouted spiral-confined lap (GSCL) connection was proposed and forty-five pull-out tests on this connection were carried out to determine the suggested lap length of deformed bars. Based on these results, an experimental study was carried out on four large-scale PC interior beam-column-slab joints containing transverse beams and slabs in order to further verify the reliability of the GSCL connection and explore reasonable precast assembling patterns for such joints. Three precast assembling patterns, that represent three arrangements of precast members and cast-in-place concrete as well as the location of connections, were designed. Four joints, including one monolithic specimen and three precast specimens, were tested under combined constant axial load and reverse lateral loading. The test results confirm that the proposed GSCL connection can significantly reduce the lap length of reinforced bars compared to the traditional lap connection. Moreover, the test results indicate that the GSCL connection can be applied in seismic regions. Two precast assembling patterns for such PC interior joints with the GSCL connection can be recommended to apply in seismic regions because the corresponding precast joints exhibited better seismic performance than the monolithic joint.
引用
收藏
页数:15
相关论文
共 49 条
[1]  
ACI (American Concrete Institute), 2002, Recommendations for design of beam-column connections in monolithic reinforced concrete structures
[2]   Seismic tests of beam-to-column connections in a precast concrete frame [J].
Alcocer, SM ;
Carranza, R ;
Perez-Navarrete, D ;
Martinez, R .
PCI JOURNAL, 2002, 47 (03) :70-+
[3]  
American Concrete Institute (ACI), 550R2R13 ACI JOINT A
[4]  
American Concrete Institute (ACI), 550R96 ACI JOINT ACI
[5]  
[Anonymous], 2014, Building Code Requirements for Structural Concrete (ACI 318-14) and Commentary (ACI 318R-14). ACI 318-14
[6]  
[Anonymous], 2012, ABAQUS User's Manual
[7]  
ASCE, 2013, 4113 ASCE ASCESEI
[8]   Beam-column joints in continuous RC frames: Comparison between cast-in-situ and precast solutions [J].
Breccolotti, Marco ;
Gentile, Santino ;
Tommasini, Mauro ;
Materazzi, Annibale Luigi ;
Bonfigli, Massimo Federico ;
Pasqualini, Bruno ;
Colone, Valerio ;
Gianesini, Marco .
ENGINEERING STRUCTURES, 2016, 127 :129-144
[9]   Experimental Investigation on the Seismic Performance of Large-Scale Interior Beam-Column Joints with Composite Slab [J].
Chen, Shicai ;
Yan, Weiming ;
Gao, Jie .
ADVANCES IN STRUCTURAL ENGINEERING, 2012, 15 (07) :1227-1237
[10]   Development and testing of precast concrete beam-to-column connections [J].
Choi, H. -K. ;
Choi, Y. -C. ;
Choi, C. -S. .
ENGINEERING STRUCTURES, 2013, 56 :1820-1835