Adequacy of automated peritoneal dialysis with and without manual daytime exchange:: A randomized controlled trial

被引:24
|
作者
Demetriou, D.
Habicht, A.
Schillinger, M.
Hoerl, W. H.
Vychytil, A.
机构
[1] Med Univ Vienna, Div Nephrol & Dialysis, Dept Med 3, A-1090 Vienna, Austria
[2] Med Univ Vienna, Div Angiol, Dept Med 2, A-1090 Vienna, Austria
关键词
dialysate flow; phosphate; beta(2)-microglobulin; sodium; protein loss;
D O I
10.1038/sj.ki.5001808
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Until now, it remains unclear whether the addition of manual daytime exchanges or increasing the nightly dialysate flow is the best strategy to optimize automated peritoneal dialysis (APD) treatment. In this open-label randomized controlled crossover trial, 18 patients with high-average (HA) or low-average (LA) peritoneal transport rates sequentially underwent two different APD regimens for 7 days each, with an intermittent washout period of 7 days. 'Manual exchange' treatment was a conventional APD with low nightly dialysate flow and one manual daytime exchange. 'High-flow' treatment was defined by cycler therapy with high dialysate flow but without manual daytime exchange. Creatinine clearances (8.56 +/- 1.22 vs 7.87 +/- 1.04 l/treatment, P = 0.011) and urea nitrogen clearances (12.83 +/- 1.98 vs 11.68 +/- 1.06 l/treatment, P = 0.014) were significantly increased during 'high-flow' treatment compared to 'manual exchange' treatment. Sodium removal was significantly lower and glucose absorption was higher with the 'high-flow' regimen. Phosphate clearances, beta(2)-microglobulin clearances, ultrafiltration, and peritoneal protein loss were not different between the two treatment modalities. Subgroup analysis dependent on peritoneal transport types showed that the effect on clearances was most marked and significant in HA transporters, whereas sodium removal was lowest in LA transporters. We conclude that small solute clearances can be significantly improved and middle molecule clearances maintained in APD patients by increasing the nightly dialysate flow instead of adding a manual daytime exchange. However, the possible benefit of better clearances with higher nightly treatment volumes has to be weighed against increased costs and the possible negative impact of impaired sodium removal, especially in LA transporters.
引用
收藏
页码:1649 / 1655
页数:7
相关论文
共 50 条
  • [1] Peritoneal sodium removal compared to glucose absorption in peritoneal dialysis patients treated by continuous ambulatory peritoneal dialysis and automated peritoneal dialysis with and without a daytime exchange
    Tangwonglert, Theerasak
    Davenport, Andrew
    THERAPEUTIC APHERESIS AND DIALYSIS, 2021, 25 (05) : 654 - 662
  • [2] Optimizing automated peritoneal dialysis: increasing nightly dialysate flow vs adding a manual daytime exchange
    Simon J Davies
    Nature Clinical Practice Nephrology, 2007, 3 : 248 - 249
  • [3] Optimizing automated peritoneal dialysis: increasing nightly dialysate flow vs adding a manual daytime exchange
    Davies, S. J.
    NATURE CLINICAL PRACTICE NEPHROLOGY, 2007, 3 (05): : 248 - 249
  • [4] Outcomes of Remote Patient Monitoring for Automated Peritoneal Dialysis: A Randomized Controlled Trial
    Jung, Hee-Yeon
    Jeon, Yena
    Kim, Yon Su
    Kim, Dong Ki
    Lee, Jung Pyo
    Yang, Chul Woo
    Ko, Eun Jeong
    Ryu, Dong-Ryeol
    Kang, Shin-Wook
    Park, Jung Tak
    Lim, Jeong-Hoon
    Choi, Ji-Young
    Cho, Jang-Hee
    Kim, Chan-Duck
    Kim, Yong-Lim
    Park, Sun-Hee
    NEPHRON, 2021, 145 (06) : 702 - 710
  • [5] Adequacy of dialysis in automated peritoneal dialysis: A clinical experience
    Rodriguez, AMF
    Diaz, NV
    Cubillo, LP
    Laborda, EB
    Umpierrez, AM
    Borges, PP
    Zurita, MN
    Toledano, CP
    PERITONEAL DIALYSIS INTERNATIONAL, 1997, 17 (05): : 442 - 448
  • [6] A Randomized Controlled Trial Comparing Automated Peritoneal Dialysis and Hemodialysis for Urgent-Start Dialysis in ESRD
    Jin, Haijiao
    Fang, Wei
    Wang, Ling
    Zang, Xiujuan
    Deng, Yueyi
    Wu, Guoqing
    Li, Ying
    Chen, Xiaonong
    Wang, Niansong
    Jiang, Gengru
    Guo, Zhiyong
    Wang, Xiaoxia
    Qi, Yinghui
    Lv, Shifan
    Ni, Zhaohui
    KIDNEY INTERNATIONAL REPORTS, 2024, 9 (09): : 2627 - 2634
  • [7] Rapid initiation of peritoneal dialysis by automated peritoneal dialysis or hemodialysis: a randomized clinical trial
    Zhang, Qianying
    Wu, Pei
    Xie, Jingyuan
    Li, Xiao
    Xu, Tian
    Huang, Xiaomin
    Zhang, Chunyan
    Chen, Nan
    Ren, Hong
    KIDNEY DISEASES, 2023, 9 (06) : 529 - 537
  • [8] The impact of increasing the daytime dialysis exchange frequency on peritoneal dialysis adequacy and nutritional status of Chinese anuric patients
    Szeto, CC
    Wong, TYH
    Chow, KM
    Leung, CB
    Wang, AYM
    Lui, SF
    Li, PKT
    PERITONEAL DIALYSIS INTERNATIONAL, 2002, 22 (02): : 197 - 203
  • [9] A randomized controlled comparative study of different fluid exchange modes in urgent-start peritoneal dialysis in patients with end-stage renal disease: automated peritoneal dialysis combined with manual fluid exchange vs. manual fluid exchange alone
    Xia, Xiaoxiao
    He, Xueqin
    Pu, Li
    Liu, Xia
    Zhou, Xueli
    Wu, Xiao Fang
    Zang, Zhiyun
    Li, Zi
    RENAL FAILURE, 2023, 45 (01)
  • [10] PERITONEAL EQUILIBRATION TEST CURVES AND ADEQUACY OF DIALYSIS IN CHILDREN ON AUTOMATED PERITONEAL-DIALYSIS
    SLIMAN, GA
    KLEE, KM
    GALLHOLDEN, B
    WATKINS, SL
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1994, 24 (05) : 813 - 818