Reduced-FOV excitation decreases susceptibility artifact in diffusion-weighted MRI with endorectal coil for prostate cancer detection

被引:96
作者
Korn, Natalie [1 ]
Kurhanewicz, John [1 ,2 ,3 ]
Banerjee, Suchandrima [4 ]
Starobinets, Olga [1 ,2 ,3 ]
Saritas, Emine [5 ]
Noworolski, Susan [1 ,2 ,3 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94107 USA
[2] Univ Calif San Francisco, Grad Grp Bioengn, San Francisco, CA 94107 USA
[3] Univ Calif Berkeley, Grad Grp Bioengn, Berkeley, CA 94720 USA
[4] Gen Elect Healthcare, Menlo Pk, CA USA
[5] Univ Calif Berkeley, Dept Bioengn, Berkeley, CA 94720 USA
关键词
Reduced FOV; Prostate; Diffusion-weighted imaging; MRI; Endorectal; ADC; 3; T; TUMOR;
D O I
10.1016/j.mri.2014.08.040
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purposes of this study were to determine if image distortion is less in prostate MR apparent diffusion coefficient (ADC) maps generated from a reduced-field-of-view ( rFOV) diffusion-weighted-imaging (DWI) technique than from a conventional DWI sequence (CONV), and to determine if the rFOV ADC tumor contrast is as high as or better than that of the CONV sequence. Fifty patients underwent a 3 T MRI exam. CONV and rFOV (utilizing a 2D, echo-planar, rectangularly-selective RF pulse) sequences were acquired using b = 600, 0 s/mm(2). Distortion was visually scored 0-4 by three independent observers and quantitatively measured using the difference in rectal wall curvature between the ADC maps and T2-weighted images. Distortion scores were lower with the rFOV sequence (p < 0.012, Wilcoxon Signed-Rank Test, n = 50), and difference in distortion scores did not differ significantly among observers (p = 0.99, Kruskal-Wallis Rank Sum Test). The difference in rectal curvature was less with rFOV ADC maps (26% +/- 10%) than CONV ADC maps (34% +/- 13%) (p < 0.011, Student's t-test). In seventeen patients with untreated, biopsy confirmed prostate cancer, the rFOV sequence afforded significantly higher ADC tumor contrast (44.0%) than the CONV sequence (35.9%), (p < 0.0012, Student's t-test). The rFOV sequence yielded significantly decreased susceptibility artifact and significantly higher contrast between tumor and healthy tissue. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:56 / 62
页数:7
相关论文
共 20 条
[1]  
American Cancer Society, 2013, CANC FACTS FIG 2013
[2]   Diffusion imaging of the prostate at 3.0 tesla [J].
Gibbs, P ;
Pickles, MD ;
Turnbull, LW .
INVESTIGATIVE RADIOLOGY, 2006, 41 (02) :185-188
[3]   Relationship between Apparent Diffusion Coefficients at 3.0-T MR Imaging and Gleason Grade in Peripheral Zone Prostate Cancer [J].
Hambrock, Thomas ;
Somford, Diederik M. ;
Huisman, Henkjan J. ;
van Oort, Inge M. ;
Witjes, J. Alfred ;
Hulsbergen-van de Kaa, Christina A. ;
Scheenen, Thomas ;
Barentsz, Jelle O. .
RADIOLOGY, 2011, 259 (02) :453-461
[4]   High-resolution DTI with 2D interleaved multislice reduced FOV single-shot diffusion-weighted EPI (2D ss-rFOV-DWEPI) [J].
Jeong, EK ;
Kim, SE ;
Guo, JY ;
Kholmovski, EG ;
Parker, DL .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (06) :1575-1579
[5]   Value of diffusion-weighted Imaging for the prediction of prostate cancer location at 3T using a phased-array coil - Preliminary results [J].
Kim, Chan Kyo ;
Park, Byung Kwan ;
Lee, Hyun Moo ;
Kwon, Ghee Young .
INVESTIGATIVE RADIOLOGY, 2007, 42 (12) :842-847
[6]   High-b-Value Diffusion-Weighted Imaging at 3 T to Detect Prostate Cancer: Comparisons Between b Values of 1,000 and 2,000 s/mm2 [J].
Kim, Chan Kyo ;
Park, Byung Kwan ;
Kim, Bohyun .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) :W33-W37
[7]  
Kitajima Kazuhiro, 2008, Magn Reson Med Sci, V7, P93, DOI 10.2463/mrms.7.93
[8]   Multiparametric magnetic resonance imaging in prostate cancer: present and future [J].
Kurhanewicz, John ;
Vigneron, Daniel ;
Carroll, Peter ;
Coakley, Fergus .
CURRENT OPINION IN UROLOGY, 2008, 18 (01) :71-77
[9]   High resolution diffusion weighted magnetic resonance imaging of the pancreas using reduced field of view single-shot echo-planar imaging at 3 T [J].
Ma, Chao ;
Li, Yan-jun ;
Pan, Chun-shu ;
Wang, He ;
Wang, Jian ;
Chen, Shi-yue ;
Lu, Jian-ping .
MAGNETIC RESONANCE IMAGING, 2014, 32 (02) :125-131
[10]   Diffusion-weighted MRI of the prostate at 3.0 T: Comparison of endorectal coil (ERC) MRI and phased-array coil (PAC) MRI-The impact of SNR on ADC measurement [J].
Mazaheri, Yousef ;
Vargas, H. Alberto ;
Nyman, Gregory ;
Shukla-Dave, Amita ;
Akin, Oguz ;
Hricak, Hedvig .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (10) :E515-E520