Analysis of metals and phosphorus in biodiesel B100 from different feedstock using a Flow Blurring® multinebulizer in inductively coupled plasma-optical emission spectrometry

被引:22
作者
Avila Orozco, Francisco D. [1 ]
Kovachev, Nikolay [2 ,3 ]
Aguirre Pastor, Miguel Angel [2 ,3 ]
Domini, Claudia E. [1 ]
Fernandez Band, Beatriz S. [1 ]
Canals Hernandez, Antonio [2 ,3 ]
机构
[1] Univ Nacl Sur, INQUISUR UNS CONICET, Lab FIA, Secc Quim Analit, RA-8000 Bahia Blanca, Buenos Aires, Argentina
[2] Univ Alicante, Fac Ciencias, Dpto Quim Analit Nutr & Bromatol, Apdo 99, Alicante, Spain
[3] Univ Alicante, Fac Ciencias, Inst Univ Mat, Alicante, Spain
关键词
Multinebulizer; ICP OES; Inorganic elemental analysis; Biodiesel; NA; CA; MG; MICROEMULSION; SAMPLES; OIL;
D O I
10.1016/j.aca.2014.04.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and fast method for determining the content of Na, K, Ca, Mg, P, and 20 heavy metals in biodiesel samples with inductively coupled plasma optical emission spectrometry (ICP OES) using a two-nozzle Flow Blurring((R)) multinebulizer prototype and on-line internal standard calibration, are proposed. The biodiesel samples were produced from different feedstock such as sunflower, corn, soybean and grape seed oils, via a base catalyst transesterification. The analysis was carried out without any sample pretreatment. The standards and samples were introduced through one of the multinebulizer nozzles, while the aqueous solution containing yttrium as an internal standard was introduced through the second nozzle. Thus, the spectral interferences were compensated and the formation of carbon deposits on the ICP torch was prevented. The determination coefficients (R-2) were greater than 0.99 for the studied analytes, in the range 0.21-14.75 mg kg (1). Short-term and long-term precisions were estimated as relative standard deviation. These were acceptable, their values being lower than 10%. The LOQ for major components such as Ca, K, Mg, Na, and P, were within a range between 4.9 ng g (1) for Mg (279.553 nm) and 531.1 ng g (1) for Na (588.995 nm), and for the other 20 minor components they were within a range between 1.1 ng g (1) for Ba (455.403 nm) and 2913.9 ng g (1) for Pb (220.353 nm). Recovery values ranged between 95% and 106%. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:15 / 21
页数:7
相关论文
共 22 条
[1]   Direct analysis of biodiesel microemulsions using an inductively coupled plasma mass spectrometry [J].
Amais, Renata S. ;
Garcia, Edivaldo E. ;
Monteiro, Marcos R. ;
Nogueira, Ana Rita A. ;
Nobrega, Joaquim A. .
MICROCHEMICAL JOURNAL, 2010, 96 (01) :146-150
[2]   Analysis of biodiesel and oil samples by on-line calibration using a Flow Blurring® multinebulizer in ICP OES without oxygen addition [J].
Angel Aguirre, Miguel ;
Kovachev, Nikolay ;
Hidalgo, Montserrat ;
Canals, Antonio .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (12) :2102-2110
[3]   Compensation for matrix effects on ICP-OES by on-line calibration methods using a new multi-nebulizer based on Flow Blurring® technology [J].
Angel Aguirre, Miguel ;
Kovachev, Nikolay ;
Almagro, Beatriz ;
Hidalgo, Montserrat ;
Canals, Antonio .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (11) :1724-1732
[4]  
[Anonymous], 2003, 14109 BS EN
[5]  
[Anonymous], 2011, D6751 ASTM
[6]   An ultrasonic-accelerated oxidation method for determining the oxidative stability of biodiesel [J].
Avila Orozco, Francisco D. ;
Sousa, Antonio C. ;
Domini, Claudia E. ;
Ugulino Araujo, Mario Cesar ;
Fernandez Band, Beatriz S. .
ULTRASONICS SONOCHEMISTRY, 2013, 20 (03) :820-825
[7]  
*BS EN, 2003, 14108 BS EN
[8]  
*BS EN, 2003, 14107 BS EN
[9]  
*BSI BS EN, 2008, 14214 BSI BS EN
[10]   The use of microemulsion for determination of sodium and potassium in biodiesel by flame atomic absorption spectrometry [J].
de Jesus, Alexandre ;
Silva, Marcia M. ;
Vale, Maria Gored R. .
TALANTA, 2008, 74 (05) :1378-1384